Working Principle of laser tattoo removal :
Laser technology has greatly improved the ability to treat melanocytic lesions and tattoos with the rapidly pulsed Q-switch neodymium: yttrium aluminium garnet (Nd: YAG) laser. The laser treatment of pigmented lesions and tattoos are based on principle of selected photothermolysis. The QS laser Systems can successfully lighten or eradicate a variety of benign epidermal and dermal pigmented lesions and tattoos with minimal risk of untoward effects.
Laser pigment removal machine though high energy of laser transient emission, make irradiated pigment particles absorb energy expansion rupture. Most or all of epidermal pigment group split into smaller tiny particles immediately ruled out in vitro. Part of dermal pigment group fragment into body macrophage phagocytic particles that ingest and excrete through the lymphatic system, thereby eliminating pigment. Due to normal tissue on 1064nm laser absorption is very few, maintaining the cell frame complete. No scar formation conditions. Because of the laser pigment removal is no damage to normal tissues, its security guaranteed maximum customer without complications from postoperative.
Gradually the pigment becomes lighter and lighter till disappearing. Gradually the pigment becomes lighter and ligher.
q-switch nd:yag laser for tattoo/ striae gravidarum/ freckle removal machine
Treatment Principle
NBW-2000B laser skin treatment device treatment principle is that using the Laser selective and adjusting Q-principle laser Blasting, making the precise dose of a specific wavelength of energy aim at a particular structor in a very short period of time---colorradical: derma and epidermis of ink, carbon particles and other exogenous and endogenous pigment granules of melanin pigment cells. Pigment be heated suddenly then occur blasting, the pigment was crushed to become smaller fragments, the crushed fragments was phagocytosed by macrophages, with the macrophage cells goes into the lymphatic circulation then pigment is excreted.
The Main Technical Specifications, Performance index:
Work condition
Environment tempreture:10~30℃;
Relative humidity:≤75%;
atmospheric pressure:860~1060hpa;
Power supply:AC220V,50Hz;
Cooling water:deionized water or distilled water
Basic Parameter
Physical demension(L×W×H,mm):400×380×800
Total weight:25kg;
Consumed power:600W;
creepage protectingrated current
Laser output method:Pulse adjusting Q
working Laser wavelength:1064nm;532nm
Laser pulse wideth:8ns±2ns;
Output frequency:1Hz,2Hz,3hz 4hz 5Hz;6hz
Single pulse max output energy:100-2000mJ;
Harmed eyes distance:NOHD 1km,operated in dense need wear eyeshield!
cooling method:Inlay closed cirlced water
Run Mode:Dwell load-on continuious running
Flare continuious adjusted
Photoelectricity Capability
Arthrosis bottom Output Max Single Pulse energy≥500mJ;
Laser Output enstablity:ST≤±10%;
Output Power reappear:Rp≤±10%;
Output Power and Preset valueshowing error:≤±20%;
Operation FlareDiameter:1-4mm continious adjusting;
Aimming at Laser outputpower Pc::0.1mW≤Pc≤5mW
Laser Wideth 8ns±2ns
Whole machine functions
Single pulse energy degree showing and adjusting
Pulse wavelenth showing and adjusting
Pulse frenquency and showing adjusting
Working condition and showing adjusting
Safety inquiry
1, the electric shock protection: Conforms to GB9706.1-2007 "Medical electrical equipment Part I: General
requirements for safety" in the Class B Type I device regulations.
2, Laser Radiation Protection: Conforms to GB7247-2001 "Radiation safety of laser products, equipment classification, requirements and user's guide", the 4 types of medical laser product radiation safetyrequirements.
Indications
1 Indications
This instrument is mainly used for eliminate some of the clinical exogenous and endogenous skin, blue,black, brown pigment lesions, such as: tattoos, tattoo, nevus of Ota and so on.
2, the treatment interval Two treatment should be about two months apart, so that the pigment particles were crushed have enough time to be absorbed.
3, number of treatment
Many cases, the treatment generally required to get better results, the number of specific treatment of patients with the concentration of pigment from the affected area, depth, pigment composition, each treatment using the laser dose, patients with macrophages in vivo absorption of pigment granules and other factors. Generally exogenous pigment treatment to be more than 3 times, 5 times the endogenous pigment to be more satisfactory than the treatment effect obtained a small number of patients with repeated treatment effect is not satisfactory.Features
1. No harm to the hair follicle and normal skin, leaving no scar.
2. Short treating time and easy operation.
3.The high quality controlled solid-state laser complying with international standard
4. Computerized with big LCD and show in double language: English and Chinese.
5.Tiny sense of pain, anesthesia is unnecessary. in most cases, no side effect
Applications:
1. Remove all kinds of tattoo.
2. Remove pigmentation formed by pathological changes of pigment skin and mixed color, dermis spot, fleck,
black nevus, age pigment, birthmark and Nevus of Ota.
3. Remove all kinds of embroider eyebrow tattoo, embroider lip tattoo, soak lip tattoo, embroider eye line tattoo and lip line tattoo.
4.With skin rejuvenation treatment head (OPTIONAL).can fade acne scar,skin rejuvenation ,skin whitening,astringe pores ,remove black head .
6. strong cooling + plug and play handle
Contraindications
1. For patients with dark skin, we suggest they take treatments after skin-whitening. Otherwise the skin maybe hurt slightly
2. After the treatment, the skin will become red and swollen or blood infiltrated, if so, patients can ice the treatment skin or apply some ointment against scar
3. Some metal ion such as ferric ion will become chemical substance, if so the skin will be darker after treatment. It is not the problem of machine self.
4, after the treatment skin should be kept clean and dry to avoid infection.
5 Postoperative Results boil, should make it off on their own in order to avoid man-induced scars.
6, Repeating treatment is prohibited in the same area, or tissue will be damaged due to heat accumulation.
Precautions and instructions
The actual components of this product have been tuned and locked, there are components with special requirements need to be sealed at the factory. Users are not allowed to unsealed, dismantling, adjustment and changes the parameters have been locked, otherwise the consequences are due to users.
The radiation shield body, device of remote interlock, key switch, warning device of laser radiation, device of Beam terminated are according to the provision of GB7247-2001. It is set for the safety protection of laser radiation, the users are not allowed to dismantle these devices, so as to affect the protective security.
Laser skin treatment device is the instruments with light, mechanical, electrical and precision in one. Therefore, the operators must be trained. Non-trained personnel are not allowed to operate the machine.
Please read this manual carefully before use, we shall not be held responsible for the medical accidents and disputes which are caused by not read or violate compasses operation.
Please must make laser far away from the non-treatment site during treatment process.
Before - after
Packaging & Shipping
Packaging Detail: aluminium box for cryolipolysis slimming machine
Delivery Detail:3-5working days for cryolipolysis slimming machine
Our Services
- 3 years warranty
- Free training for operation
- On-line services
- OEM/ODM services
Welcome to our factory any time
Contact us
Bella
Beijing Nubway S&T Co,Ltd
Web:
Skype:648667322
Phone:0086-10-5120-6522
Mobile:0086-15600848595
Our Advantages
1.With infrared light, more accurate shoting treatment area.
2.Different machine chassis option matches style of hospital, clinic, salon, beauty spa, home use, etc.
3.Water temperature and water flow alarm system ensure long time safe working.
4.Germany imported laser rod ensures higher light transmittance, with better working performance.
5.Taiwan import power supply, confirm the machine stable and strong output energy.