Portable CE Certification Ultra Pulse CO2 Fractional Tumour Removal Laser Gynecology Medical Equipment Face Whitening 560-1200nm
Negotiable /Set
Min.Order:1 Set
Beijing Nubway S & T Co., Ltd.
Fuctions and treatment effect of elight ipl rf
1.Permanent hair removal.
2.Smooth wrinkles, face-lifting
3.Deep flecks, epidermis flecks or pigment treating the telangiectasis
4.Promote collagen to grow, strengthen flexibility of skin
5.Acne treatment
6.Shrink the thick pore
7.For endogenous pigment: nevus of Ota, coffee spot, age pigment, freckle etc removal
8.For exogenous pigment: tattoo, eyeliner and eyebrow removal
9.Skin whitening
10.Striae gravidarum removal
Principle of RF CO2 Fractional Laser
CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger.
CE Certification Ultra Pulse CO2 Fractional Laser Gynecology Medical Equipment
Laser type | USA Coherent laser |
Wavelength | 10600nm |
Power | 30W |
Laser working mode | Continuous The range of IPL treatment: (1)Everlasting hair removal:remove unwanted hairs under arms,on legs ,lips or other body part,etc. (2)Pigmentation treatment:remove various kinds of pigment such as freckle,chloasma,aged spots,sunburn,etc. (3)Telangiectasis treatment:treat angiotelec-tasis. (4)Acne treatment:papule,tuber,Blain,acne,etc. (5)Shrink pores,tighten skin,improve skin elasticity and glossiness. (6)Eliminate and smooth wrinkles,acne treatment. |
Output mode | Ultra pulse, Single pulse, Fractional |
Fractional working mode | interval continuous working |
Pulse width | 1-100ms |
Output Graphics | Square, rectangle, round, triangle, oval, 6-diamond shape, line or customized graphics |
Light guiding system | 7 joints arm |
Scanning mode | Sequence mode, Mid split mode, Random mode |
Scan pattern size | 0.1*0.1mm - 20*20mm |
Scan area | Maximum 25x25mm |
Aiming beam | 650nm, ≤5mw |
Cooling system | Wind cooling Main Technical Parameters: Laser wavelength: 10.6µm Laser unit:TEM00 module Co2 unit (best quality for the facula) Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm Pulse width: the minimum pulse width is 0.1ms |
Power supply | AC 220V±10%,50Hz AC 110V±10%,60Hz |
The RF equipment has the cooling system of surface layer, and uses proprietary technology
to deliver radiofrequency energy to the deep layers of the skin and its underlying tissue. The
heat will accelerate the blood circle, lets the fibre structure shrink instantaneously, and
stimulates the renewal of collagen. In response, the collagen shrinks and remodels over time,
providing you with tighter skin, renewed facial contours.
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
Beijing Nubway S & T .co. ltd was founded in 2003,we are one of the most professional manufacturer of Medical beauty equipment in Beijing China, we have in this business for more than 10 years. We have the most professional factory, best engineer and technical team, R &D team and service team. Nowadays, our high quality products are utilized in over 70 countries around the world, and have already won an international reputation, attracting the customers by our advanced technologies, unique designs, powerful functions and efficient services.
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
Treatment theory
e-light beauty equipment CE beauty machine combines three advanced technologies:Bipolar Radio Frequency + IPL + Skin Contact Cooling
The working theory is heating the dermis to a target temperature gradually,at that target temperature, it damages the hair follicles and prevents re-growth effectively,meanwhile avoiding injury to the surrunding tissue.A high repetition rate of single pulses are delivered deep into the dermis,achieving high average power and therappeutically effectively heat bulit-up,without the risk of injury and no pain virtually.