40w Acne Scar Removal Portable RF Tube Fractional Co2 Laser Skin Professional 100um-2000um Resurfacing Machine/co2 Laser Facial Winkle Removal/fractional Co2 Laser Equipment Remove Neoplasms
USD $1 - $4,800 /Set
Min.Order:1 Set
Lianyungang Zhengjia Beauty Equipment Co., Ltd.
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
Working principle of fractional CO2 laser and vaginal tightening laser
1. skin resurfacing fractional CO2 laser
Fractional ablative CO2 resurfacing delivers 10600nm laser in fractional manner into the skin while leaving the untreated surrounding areas intact. Laser creates microscopic thermal dot on surface and performs within tissues, offering improve skin tightening, age spots, fine lines, acne scars, stretch marks removal and vulva rejuvenation. The untreated tissue helps to accelerate the healing process and rejuvenate the skin by promoting micro-circulation and new cell genesis.
2. vaginal tightening fractional CO2 laser
Fractional CO2 laser 10600nm is a very mature technology in the market. It creates microscopic thermal dots on the skin. These dots serves to enhance vaginal muscle tone, strength, and elasticity, while the intact skin helps these thermal dots recover.
It has an automatically 360° rotation articulate arm probe. It emits laser energy at a controlled depth inside the vaginal mucosa and achieve the functions of tighten vaginal, improve vaginal dryness, etc.
RF Fractional Co2 Laser Machine/co2 laser tube 60w/fractional co2 medical laser RF Fractional Co2 Laser Machine/co2 laser tube 60w/fractional co2 medical laser
3. Multi-functionl fractional CO2 laser for vaginal tighening and skin resurfacing
It's a more economic machine with both vaginal tightening and skin resurfacing function.
portable RF tube fractional co2 laser machine/co2 laser facial winkle removal/fractional co2 laser equipment
portable RF tube fractional co2 laser machine/co2 laser facial winkle removal/fractional co2 laser equipment
1. wipe off acne, acne scar, scar and so on;
2. T2 wrinkle around the eyes, crow's-feet, and wrinkle formed by lack of water;
3. Effectively wipe off the wrinkle on the face, forehead, the joints and striae gravidarum;
4. clear up freckle, nevus zygomaticus and other spots formed by hyperchromic pathological changes;
5. Tighten skin and lift face;
6. wipe off striae gravidarum and other deep scars
portable RF tube fractional co2 laser machine/co2 laser facial winkle removal/fractional co2 laser equipment
Electrical Requirements | AC 110V±10% 60Hz; AC 220V± 10%50Hz | Beam Delivery | 6 joint arm |
Wavelength | 10600nm | Cooling | Air cooling |
Aiming wavelength | 635nm | Output mode | Continuous;Super pulse;Fractional |
Focal Spot Diameter | 0.2mm | Operating mode | Continuous;Operation with Intermittent loading |
Power of Aiming Beam | ≤ 5mw | WhetherPreviewor not | Yes |
Pulse Interval | 1ms-5000ms;Every stepping 1ms | Times of scanning | 1th-20th;Every stepping 1th |
Pulse Width | 0.1ms-10ms;Every stepping 0.1ms | Scanning Mode | Free scan;Sequence sacn;Maximum distance scan |
Output Power | 20W (30W, 40W optional) | Output Pattern | Beeline;trangle;rightsquare;rectangle;hexagon;rotundity; |
1%-100%(adjustable) | ellipse and so on | ||
every stepping1% | |||
Spots Interval | 0.1mm-2.6mm;Every stepping 0.1mm | Pattern Size | Diagonal length from ;0.1mm to 20mm is adjustable at random |
Machine weight | 30KG | Packing weight | 45KG |
Machine size | 65cm x36cmx 31cm |
advantage of portable RF tube fractional co2 laser machine/co2 laser facial winkle removal/fractional co2 laser equipment
1.Fast treatment;Super treatment area and high pulse energy can enable you to treat an entire face in as little as 10 minutes
2.Micro single DOT; Minimum 120 mictromenters small spot size delivery to deeper skin
3.Customizale treatment;Control the pattern, density and energy easily, offer the flexible possibilities of treatments
4.Cost effective;1 year warranty for RF excited CO2 laser tube, no consumables, offer affordable with a high return on investment
5.Fractional scanner pattern size and shape
6.RF metal tube imported from US
7.Perfect treatment result and quick restore
8.Portable design easy for move and maintenance
Aluminum box suitable for shippment safety
By sea,By Air,By DHL/UPS/TNT/FEDEX as customer’s request.
Please tell us your nearest Sea-port or Air-port, we will offer the quotation with shipping cost.
ONE-STOP purchase service for you here.
Features & Advantages:
1) Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues .
2) Reduced thermal damage to surrounding tissues
3) Rapid healing and minimal downtime
4) Stimulate deeper collagen with high pulse energy
5) Adjustable scanning patterns and size.
6) Adjustable intensity of pilot beam from zero to maximum
7) Adjustable pulse duration
8) Last treatment setting memorization
9) Automatic alarm system for operation and troubles
10) Covers all functions of conventional system
11) No consumable costs.
12) High Energy Outputs, high effective
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).