Pigmented Spot Removal Fast Hair Removal IPL Skin Tightening SHR Device Advanced AFT SHR MED-140C+ Pigment Removal
USD $1 - $9,999 /Set
Min.Order:1 Set
Beijing KES Biology Technology Co., Ltd.
Redness Removal Fast Hair Removal Skin Whitening E-light IPL SHR Device MED-140C+ 10MHz
2015 selling equipment sewing machine skin free skins for laptops
active hair removal harmless hair removal ipl beauty equipment for skin rejuvenation sunburn
active hair removal harmless hair removal acne removal ipl elight med140c+
skin whitening beauty salon device skin rejuvenation instrument med-140c+
Our Services
1.We will guarantee the quality of our equipment, all the beauty machines will have over 48 hours test, then the QC department check again the stability before packing.
2.If there is a deficiency, please leave message or call us, our technical department will check the machinesituation face to face on internet or you take some videos to show the situation. We will give reply and solve method within 24 hours.
fast hair removal IPL SHR device Advanced AFT SHR
MED-140C+
Features:
l Permanent Hair Removal
l Fast treatment. Frequency up to 10Hz!
l Big spot size: 15*50mm
l Painless: new AFT technology (Advanced Fluorescence Technology) uses low and equal energy. The special filter cut s 950-1200nm wavelength, which is useless in treatment and absorbs water to make patient feel painless
l Hairfree,even on work on blonde, red or fine hair
l Skinfree, suitable for all skin types, even tanners
l Accurate Software control and parameters adjustable
What's SHR ?
SHR=Super Hair Removal,it’s a revolutionary technology of hair removal which is having a sweeping success. (adopt technology AFT,EDF)
SHR combines laser technology and the benefits of the pulsating light method achieving practically painless results.
SHR combined with “In Motion” represents a breakthrough in permanent hair removal with light technology. The treatment is more pleasant than with the conventional systems and your skin is better protected.
Difference Of IPL SHR & Traditional IPL or laser
Traditional laser or IPL technologies employ short impulses of approximately 2-300 milliseconds, applying a vast amount of energy (12-120 J/cm2). Energy is transported to the hair root through melanin, where warmth of 65-72° Celsius is produced. Energy reaches the root of the hair follicle solely through melanin. Skin and red blood cells have a similar absorption coefficient as melanin and therefore also absorb the high levels of energy produced by the laser and IPL methods.
SHR technology, on the other hand, utilizes the melanin path only partially (50%)., and combining In-Motion technology, gently warms the skin helping penetrate down to the follicles which produce hair growth.
Research has shown that a slower, but longer heating process is considerably more effective for permanent hair removal than high and short levels of energy. Therefore, when using SHR, the device is passed over the tissue multiple times (in motion) using low energy but a high rate of repetition (up to 10Hz, i.e. 10 times per second) instead of using the traditional method with single, high-energy impulses. Thus, the hair melanin, as well as the tissue of the stem cells, is heated with low energy at a slow pace and over a longer period of time to a comfortable temperature of 45° Celsius.
Technical specifications:
Wavelength (Spectrum) | 650-950nm(HR) 510-1200nm(SR) ,15*35mm (430/530/640-1200nm) |
Energy Density (Fluence) | 1-30J/cm2(SHR) 1-60J/cm2(Normal) |
RF Energy | Up to 50W |
Spot Size | 15x50mm2 (HR);10x40mm2 (SR); 15*35mm2 (interchangeable) |
Pulse Repetition Rate | 0.2-10Hz |
IPL Peak Power | 2500W |
RF Power | Max. 100W |
Cooling | Continuous Crystal contact cooling (-4°C-2°C ) + Air cooling + Closed water circulation cooling |
Stand-by Working Working Theory: Applying the technology of IPL and Bipolar Radio Frequency, the system acts on the entire corium layer, epidermal layer and subcutaneous tissue. On one hand, IPL destroys pathological pigments by photothermolysis effect, and stimulates the collagen and elastic fiber and gets the effect of tightening and whitening, on the other hand, biopolar RF release about 10 MHZ radio wave, high frequency vibration makes the skin molecule creating heat energy by friction, when the temperature reaches 68℃-72℃,the collagens extend will reproduce and recombine, enhance getting the effect of tightening skin and removing wrinkles. | Continuously for 18 hours |
Display | 10.4" True Color LCD Touch Screen |
Electrical Requirements | 100-240VAC, 20A max., 50/60Hz |
Net Weight | 60 kgs |
Dimensions (WxDxH) | 63*53*126cm |
1.Warranty:12 months for host machine , Lifelong Maintenance Service. 2. Once the machine have any malfunction during the operation, how to do? Please rest assure if you met such problem, because KES has a professional after-sale service team which can reach you immediately and solve the machine’s problem within 1-3 days.For details, please contact with us freely 3.If the machines broken during the shipment, how to do? Generally there will be transportation insurance in the shipment, once there is any damage during the transportation, KES will help you to solve the claims with the insurance companies to collect your money back in time.
1.KES factory: 2.Trade show 3.Certifications: Currently our products are all Medical CE, CE, ISO13485 approved, some models has passed FDA 510K; Besides, we are Alibaba and “ Made-in-china” 's Assessed Supplier too!
1. What is the Payment Terms? Re: T/T (Wire Transfer), Western Union 2. How do you delivery the machine? Re: By door to door service, say DHL,UPS,TNT,FEDEX,etc ,Or air cargo 3. What about the delivery? Re: About 14 working days. 4. What’s your warranty? Re: 12 months for host machine. 5. Do you offer clinical training? Re: Yes .Welcome to our company for free and professional training. 6. Do you offer OEM/ODM service? Re: Yes .Welcome to contact us for more details. 7. How many treatments are required? Re: 4~6 times per course of treatment.
Treatment Principle
Precipulse IPL Therapy System follows selective photothermolysis principle.Certain wavelength that can be used in and absorbed by targeted tissues.Targeted tissues will be destroyed according to targeted chromophore's selective absorption to light.What's more,the pulse width shall be smarller than or equal to targeted tissues' thermal relaxation time,then its damage to surrounding tissues will be minimized because of insufficient time for heat delivery.