Vascular Lesions Removal New E-light 590-1200nm IPL +RF Armpit Hair Removal

Vascular Lesions Removal New E-light 590-1200nm IPL +RF Armpit Hair Removal

USD $1 - $2,350 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Beijing
Payment Terms:
D/P D/A Credit Card

Quick Details View All >

IPL+ RF:
Yes
Certification:
CE, ISO13485 , Medical CE
Place of Origin:
Beijing, China
Brand Name:
KES LEADER
Model Number:
MED-100C
Feature:
Hair Removal, Face Lift, Pigment Removal, Skin Tightening, Skin Rejuvenation, Tattoo Removal, Wrinkle Remover

Beijing KES Biology Technology Co., Ltd.

Business Type: Manufacturer,Trading Company
Beijing China
Main Products: Intense Pulsed Light Therapy Apparatus ,Nd: YAG Laser Therapy Systems

Product Details


Applications:

 

Skin rejuvenation: pores refining, improve rough, dark and gloomy skin, restore skin elasticity

Pigment treatment: freckles, sun-burn spots, senile plaque, pigmentation spots

Hair removal: armpit, chest, lip, arms, legs, beard, bikini etc.

Vascular, spider angioma, acne rosacea

Acne: pimples, improve seborrheic oily skin and acne scars


Specifications


2 Double counter system on handpiece and screen
3 Footswitch and Button switch =Safty

Best E-light Beauty Machine

Applications

 750-1200nm:   Hair Removal (Skin Type  IV)

 690-1200nm:   Hair Removal (Skin Type  III)

 640-1200nm:   Hair Removal (Skin Type  I & II ) ; Wrinkle Removal

 590-1200nm:   Pigmentation and Vascularity; Skin Rejuvenation

 560-1200nm:   Vascular and Pigmented Lesions; Skin Rejuvenation

 530-1200nm:   Skin Rejuvenation; Superficial Vascular Lesions

 


IPL Instruction

 

When IPL irradiates the skin, light energy with particular wavelength will be selectively absorbed by melanin 

of hair follicles .When the heated temperature of follicles reaches high enough their structures will be 

damaged irreversibly, finally to achieve the effect of removing the unwanted hair. 


510-1200nm:   Superficial Vascular Lesions

 480-1200nm:   Light Pigmentation

 430-1200nm:   Acne

 RF Treatment:  Skin Tightening and Face Lifting

Contrast Photos (Before & After)

New E-light IPL +RFNew E-light IPL +RF

How it works?

E-Light is the perfect combination of MED-IPL technology with Bi-polar Radio Frequency (RF) and Skin Contact Cooling. 

Radio Frequency is independent of melanin and thus independent of skin type. With Radio Frequency, increased selectivity and deeper dermal penetration would be achieved, thus lower energy is applied during the IPL treatment. Uncomfortable feeling during the IPL treatment will be decreased significantly and better result can be expected.  That is, less optical energy (IPL), when synergistically combined with Bi-polar RF, improves the safety factor when treating all skin types. 

Meanwhile, contacting surface cooling technology applied on the treatment probe head can eliminate the heat effect attributed to optical energy, and increase the resistance of surface skin, reduce the RF absorption of the surface skin, greatly improving both the treatment performance and safety.  The technology is equally applicable and effective to mild color target tissues.

  New E-light IPL +RF 

Unique Advantages

1. Humanized handle design,easily carry! 

2. Double counter system on handpiece and screen

3. Footswitch and Button switch =Safty+Convenience

 

 

 

 

 

New E-light IPL +RF

 

 

Technical Specifications

 

Wavelength (Spectrum)

430/530/640-1200nm (standard)480/560/590/690/750-1200nm (optional)

Energy Density (Fluence)

1-50J/cm2

RF Energy

Up to 50W

Spot Size

12x33mm² (standard)15x35mm²; 15x50mm² (optional)

Pulse Repetition Rate


How does it works?

 

IPL treatment is effective based on its selective absorbability. When the intense pulsed light penetrates the epidermis, the energy of light will be greatly absorbed by the pigments in epidermis. High energy and dark color skin will be with high risk in treatment. Moreover, majority of the heat is reflected andrefracted at the same time, only 30% to 40% of energy is utilizable. Therefore, it needs to increase the energy for a better treatment result. However, majority heat is absorbed by the pigments inepidermis, which directly block to use high energy for treatment, so that affects the single treatment result.


0.2Hz; 1Hz

Pulse Duration

0.5-15ms

Pulse Delay

1-50ms

Pulses

1-10 pulses

IPL Peak Power

1200W

RF Power

Max. 100W 

Cooling

Continuous Crystal contact cooling (-4°C~4°C ) + Air cooling + Closed water circulation cooling

Stand-by Working

Continuously for 12 hours

Display

7" True Color LCD Touch Screen

Electrical Requirements

100-240VAC, 20A max., 50/60Hz

Net Weight

24 kgs

Dimensions (WxDxH)

60*46*34cm

 

*Warranty:

We have 12 months warranty, and on-line service is always available

New E-light IPL +RF

 

* OEM and ODM services are our specialty, and welcome to contact us!

 

 
 


The principle of IPL

 

Applying the technique of IPL and Bipolar Radio Frequency,the equipment acts on the entire skin corium and connective tissue,stimulates the collagen of different depth to realing and grow,the gets treatment effect.Biopolar RF release energy at the same time,with the selective absorbtion for the skin to light energy,various pathological tissues of corium and epidermis creates photothermolysis effect.Since light energy is far below conventional IPL,the pigment tissue and vascular pathological tissue of the corium and epidermis would absorb more energy without injuring the epidermis,and then remove these pathological tissue better and get the effect.


Contact Supplier

Ms. Selina wu Sales General Manage Chat Now
Telephone
0086-10-84405668
Mobile
18701440334
Fax
0086-10-84404920
Address
No.15,2 district ,Mafang industry park,Pinggu gardon ,Zhongguancun Science Park, Pinggu district Beijing

You May Like