Vascular Treatment Medical CE Approved E-light IPL RF Professional Hair Removal & Wrinkle Removal Device Age Spot Removal
USD $1 - $5,000 /Set
Min.Order:1 Set
Beijing KES Biology Technology Co., Ltd.
690-1200nm Elight(IPL+ RF)/ IPL Hair Removal And Acne Removal Machine 640-1200nm
E-light(IPL+RF) machine MED140C+(Medical CE)permanent hair removal
E-light(IPL+RF) machine MED140C+(Medical CE)hair permanent removal
Medical CE Latest E light IPL RF machine permanent hair removal
Painless Latest E-light(IPL+RF) Machine MED140C+(Medical CE) Fine Lines Removal
Latest E-light(IPL+RF) machine MED140C+(Medical CE) facial hair removal
IPL SHR Machine advantages:
1. The pulse energy keep stable, not fade away
2. Icons combined with letters on the screen, more easy for understanding and operating
3. Two fans equiped on the sides for better heat dissipation
4. Inner the back of machine, the lines are neat, the consumables keep on the outside, for easy replacement
E-Light MED-210 beauty equipment
Hair removal/skin rejuvenation/Wrinkle removal/Acne treatment
1.Applications
1) 750-1200nm: Hair Removal (Skin Type IV)
2) 690-1200nm: Hair Removal (Skin Type III)
3) 640-1200nm: Hair Removal (Skin Type I & II ) ; Wrinkle Removal
4) 590-1200nm: Pigmentation and Vascularity; Skin Rejuvenation
5) 560-1200nm: Vascular and Pigmented Lesions; Skin Rejuvenation
6) 530-1200nm: Skin Rejuvenation; Superficial Vascular Lesions
7) 510-1200nm: Superficial Vascular Lesions
8) 480-1200nm: Light Pigmentation
9) 430-1200nm: Acne
10) RF Treatment: Skin Tightening and Face Lifting
2.How it works?
E-Light is the perfect combination of MED-IPL technology with Bi-polar Radio Frequency (RF) and Skin Contact Cooling.
Radio Frequency is independent of melanin and thus independent of skin type. With Radio Frequency, increased selectivity and deeper dermal penetration would be achieved, thus lower energy is applied during the IPL treatment. Uncomfortable feeling during the IPL treatment will be decreased significantly and better result can be expected. That is, less optical energy (IPL), when synergistically combined with Bi-polar RF, improves the safety factor when treating all skin types.
Meanwhile, contacting surface cooling technology applied on the treatment probe head can eliminate the heat effect attributed to optical energy, and increase the resistance of surface skin, reduce the RF absorption of the surface skin, greatly improving both the treatment performance and safety. The technology is equally applicable and effective to mild color target tissues.
3.Unique Advantages
1) Butterfly design= Hot Sales!
2) Intelligent+ professional operation=parameters setting automatically
3) Lamps for promotion (30,000-100,000shots for option)
4) 12000UF capacitor big power,ensure stable output energy
5) Magnetic drive pump controlled water circulation: lower noise, longer lifetime
4.Technical Specifications
Wavelength (Spectrum) | 640-1200nm(HR) Our Services 1.We will guarantee the quality of our equipment, all the beauty machines will have over 48 hours test, then the QC department check again the stability before packing. 2.If there is a deficiency, please leave message or call us, our technical department will check the machinesituation face to face on internet or you take some videos to show the situation. We will give reply and solve method within 24 hours. |
Energy Density (Fluence) Working Theory: Applying the technology of IPL and Bipolar Radio Frequency, the system acts on the entire corium layer, epidermal layer and subcutaneous tissue. On one hand, IPL destroys pathological pigments by photothermolysis effect, and stimulates the collagen and elastic fiber and gets the effect of tightening and whitening, on the other hand, biopolar RF release about 10 MHZ radio wave, high frequency vibration makes the skin molecule creating heat energy by friction, when the temperature reaches 68℃-72℃,the collagens extend will reproduce and recombine, enhance getting the effect of tightening skin and removing wrinkles. | 10-60J/cm2 |
RF Energy | Up to 50W |
Spot Size | 15x50mm2 (HR) |
Pulse Repetition Rate | 0.2Hz; 2Hz |
Pulse Duration | 0.5-15ms |
Pulse Delay | 1-50ms |
Pulses | 1-15 pulses |
IPL Peak Power | 1400W |
RF Power | Max. 100W |
Cooling | Continuous Crystal contact cooling (-4°C~4°C ) + Air cooling + Closed water circulation cooling |
Stand-by Working | Continuously for 12 hours |
Display | 8.4" True Color LCD Touch Screen |
Electrical Requirements | 100-240VAC, 20A max., 50/60Hz |
Net Weight | 27 kgs |
Dimensions (WxDxH) | 52*60*37cm |
*Warranty
12 months warranty with 24hours after-sale on-line service!
OEM/ODM are welcomed
Treatment Principle
Precipulse IPL Therapy System follows selective photothermolysis principle.Certain wavelength that can be used in and absorbed by targeted tissues.Targeted tissues will be destroyed according to targeted chromophore's selective absorption to light.What's more,the pulse width shall be smarller than or equal to targeted tissues' thermal relaxation time,then its damage to surrounding tissues will be minimized because of insufficient time for heat delivery.