Professional Hospital Use Equipment Fractional Wart Removal Laser Co2 Skin Excision Vaginal Tightening Warts Removal
USD $1,999 - $19,999 /Set
Min.Order:1 Set
Beijing KES Biology Technology Co., Ltd.
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
Professional hospital use equipment fractional laser co2 skin excision vaginal tightening
Model No.:MED-870+ Principle of RF CO2 Fractional Laser CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger.
Co2 fractional laser/ Scar removal laser machine/skin rejuvenation laser
1. Applications of Professional RF Fractional CO2 Laser MED-870+
l Skin Resurfacing (Superficial Peeling)
l Scar Removal: Acne scars, burnt scars and surgery scars, etc
l Collagen Stimulation
l Ablation and coagulation for the treatment of skin furrows and other textural irregularities.
l Dermatological Surgery (including Striae Gravidarum)
2. Contrast Photos (Before & After)
3. How it works?
Fractional CO2 laser therapy works mainly on the principle of fractional heat damage. The fractional CO2 laser creates microscopic holes in the upper layer of skin and leaves the deeper part of the skin intact.
The purpose of the treatment is to create controlled heat damage at the basal layer of skin leading to the reduction of wrinkles, pigmentation and acne scarring. The fractional CO2 laser also tightens and refines the skin as well as improving the long term collagen and elastin reproduction
4. Unique Advantages of Professional RF Fractional CO2 Laser MED-870+
1) USA Coherent Metal Tube(RF-excited)
2) 2 in 1 system: Fractional + Surgical (ultrapulsed laser)
3) Aiming Beam adjustable, insure precise treatment
5. Technical Specifications of Professional RF Fractional CO2 Laser MED-870+
Wavelength | 10,600nm |
Power Output | 1-40W |
Laser Type | UltraPulse; CW; Fractional |
Spot Size Application:
1. Application Range of Fractional treatment handpiece 2. Application Range of Incision Handpiece | 0.12mm & 1.25mm (adjustable) |
Spot Density | Up to 102400 dot |
Scan Size | Up to 20x20mm |
Scan Shapes | Square; Rectangle; Circle; Triangle; Rhombus; Ellipse; Line |
Beam Patterns | Standard; Random; Scatter |
Aiming Beam | 5mW red diode laser, 635nm, adjustable intensity, blink on/off |
Beam Delivery | Articulated 7-joint arm with up to 360° rotation |
Cooling | Self-contained, closed cycle |
Stand-by Working | Continuously for 18 hours |
Display | 10.4" True Color LCD Touch Screen |
Electrical Requirements | 100-240VAC, 20A max., 50/60Hz |
Net Weight | 52 kgs |
Dimensions (WxDxH) | 52*38*117cm |
6. Safe package with thick foam inside to avoid any damage during long transportation!
ODM and OEM services are our specialty, and welcome to contact us!
Beijing KES Biology Technology Co., Ltd.
Main Technical Parameters:
Laser wavelength: 10.6µm
Laser unit:TEM00 module Co2 unit (best quality for the facula)
Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W
Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode
Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible
Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery
Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface
Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm
Pulse width: the minimum pulse width is 0.1ms