50W Triple Output power supply
Negotiable /Piece
Min.Order:100 Pieces
Yueqing Xinyang Automation Equipment Co., Ltd.
50W Triple Output power supply
100% full load burn-in test
AC input: 110/220VAC± 20% selectable by switch
Protections: Short circuit/Overload
Low cost, high reliability
Size: 159*97*38mm
2 year warranty
Model | T-50A | T-50B | T-50C | ||||||
Specification | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
Specification | 5V 7A | 12V 1A | -5V 1A | 5V 5A | 12V 1A | -12V 0.5A | 5V 4A | 15V 1 A | -15V 1A |
Wave and noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability | ± 0.5% | ± 1% | ± 0.5% | ± 0.5% | ± 1% | ± 0.5% | ± 0.5% | ± 1% | ± 0.5% |
Load stability | ± 1% | ± 4% | ± 4% | ± 1% | ± 4% | ± 4% | ± 1% | ± 4% | ± 4% |
Efficiency | 66% | 69% | 71% | ||||||
Adjustable range for DC voltage | CH1: +10, -5% | CH1: +10, -5% | CH1: +10, -5% | ||||||
AC input voltage range | 85-264VAC? 47-63Hz; 120-370VDC | ||||||||
AC input voltage range | Cold-start current 30 A/115V 60A/230V | ||||||||
OverLoad protection | 105%-150% hiccup mode, auto-recovery | ||||||||
OverLoad protection | CH1.5.75-6.75V | ||||||||
Setup, rise, hold up time | 800ms, 50ms, 10ms/115VAC? 300ms, 50ms, 80ms/230VAC | ||||||||
Withstand voltage | I/P-O/P: 3KvAC I/P-FG: 1.5KvAC O/P-FG: 0.5KvAC 1minute | ||||||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ | ||||||||
Working temperature | -10— +/-50 | ||||||||
Safety standards | Design refer to GB4943, UL60950, EN60950 | ||||||||
EMC standards | Design refer to GB9254, EN55022 class A | ||||||||
Weight | 0.54kg |