hot selling 10/100/1000Base Gigabit Industrial Ethernet Switch for Digital substation
USD $350 - $420 /Piece
Min.Order:1 Piece
Shenzhen InMax Technologies Co., Ltd.
InMax i712A Series full Gigabit managed Industrial Ethernet Switches | |||
Main Features | |||
4 100/1000BaseX SFP Ports and 8 10/100/1000BaseTX Ports | |||
InMax Ring Protocol “InMax Ring" (recovery time < 20ms) and RSTP/STP for network redundancy | |||
SNMPv1/v2c/v3 for different levels of network management | |||
Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning | |||
IGMP snooping for filtering multicast traffic | |||
Easy network management through web browser, CLI, Telnet /serial console, SNMP | |||
Industrial-grade design with -40 to +75°C operating temperature and redundant power inputs | |||
Metal, IP40 protection,DIN-Rail mounting, wall mounting | |||
Introduction | |||
The i712A series managed Industrial Ethernet switches are equipped with up to 12 Gigabit Ethernet ports. The “InMax Ring” redundant Ring (recovery time < 20ms), RSTP/STP can increase system reliability and your network availability. Industrial-grade design with -40 to +75°C operating temperature and redundant power inputs. The super hardware reliability is especially suitable for industrial applications. | |||
Features and Benefits | |||
Up to 12 Gigabit ports(4 100/1000BaseX SFP ports and 8 10/100/1000BaseTX ports) | |||
Command Line Interface (CLI) for quickly configuring major managed functions | |||
InMax Ring Protocol “InMax Ring” (recovery time < 20 ms), RSTP, STP and MSTP for network redundancy | |||
IGMP snooping and GMRP for filtering multicast traffic | |||
Support up to 16k byte Jumbo Frame | |||
Support 8K MAC address | |||
Max. Number of Available VLANs: 4094 | |||
Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning | |||
DHCP Option 82 for IP address assignment with different policies | |||
Support port mirroring | |||
Support traffic control of multicast and broadcast | |||
QoS and ToS/DiffServ to increase determinism | |||
Port Trunking for optimum bandwidth utilization | |||
SNMPv3, IEEE 802.1X, HTTPS, and SSH to enhance network security | |||
SNMPv1/v2c/v3 for different levels of network management | |||
RMON for efficient network monitoring and proactive capability | |||
Bandwidth management prevents unpredictable network status | |||
Lock port function for blocking unauthorized access based on MAC address | |||
Automatic warning by exception through e-mail, relay output | |||
Specifications | |||
Technology | |||
Ethernet Standards | IEEE 802.3 IEEE 802.3u IEEE 802.3z IEEE 802.3ab IEEE802.3-2005 Clause 58/59 IEEE 802.1X (Security) IEEE 802.3x (Flow Control) IEEE 802.3ad (Link Aggregation) IEEE 802.1D (STP) IEEE 802.1w (RSTP) IEEE 802.1s (MSTP) IEEE 802.1Q (VLANs) IEEE 802.1Q (GVRP/GARP) IEEE 802.3ac (VLAN Tag Frame Extension) IEEE 802.1p (CoS) | ||
Administration Protocol | RFC 826 (ARP)RFC 826 (ARP) | ||
RFC 1812 (IPv4 Router) | |||
RFC 783 (TFTP) | |||
RFC 768 (UDP) | |||
RFC 791 (IP) | |||
RFC 792 (ICMP) | |||
RFC 793 (TCP) | |||
RFC 2474 (Diffserv) | |||
RFC 2131 (DHCP) | |||
RFC 2267 (Network Ingress Filtering) | |||
RFC 1156 (TCP/IP MIB) | |||
RFC 1212 (Concise MIB definitions) | |||
RFC 1213 (MIB for Network Management of TCP/IP based internets (MIB II) | |||
RFC 2618 (Radius Authentication Client MIB) | |||
RFC 2620 (Radius Accounting MIB) | |||
RFC 2765 (Stateless IP/ICMP Translation Algorithm) | |||
RFC 2819 (Remote Network Monitoring MIB (group 1,2,3,9) | |||
RFC 1757 (RMON (groups 1 2 3 and 9) | |||
RFC 1157 (SNMP) | |||
RFC 1902 (SNMPv2) | |||
RFC 1901 (Community based SNMPv2) | |||
RFC 2271 (SNMPv3 Architecture) | |||
RFC 2573 (SNMPv3 Applications) | |||
RFC 2576 (Coexistence between SNMP V1, V2, V3) | |||
RFC 854 (Telnet) | |||
RFC 896 (Congestion control in IP/TCP network) | |||
RFC 1122 (Requirements for Internet Hosts) | |||
RFC 2597 (Assured Forwarding PHB group (partial support) | |||
RFC 2865 (Remote Authentication Dial In User Service) | |||
RFC 2869bis (Radius Support for Extensible Authentication) | |||
Ethernet Specifications | Store and forward mode: Non-blocking switching | ||
Switch fabric:24Gbps | |||
Support up to 16k byte Jumbo Frame | |||
Support 8K MAC address | |||
Support MAC address black hole | |||
Support MAC address learning limit | |||
Support port-based VLAN | |||
Support 802.1Q VLAN (4K VLANs) | |||
Support protocol-based VLAN | |||
Support GVRP/GARP (Generic VLAN Registration Protocol) | |||
Support VLAN isolation (16) | |||
Support VLAN translation | |||
Support VLAN VPN (QinQ) | |||
Support LACP | |||
Support static link aggregation | |||
Support up to 16 aggregation groups and up to 8 ports per group | |||
Support 802.3x in full duplex mode | |||
Support back pressure in half duplex mode | |||
Discovery remote base on link layer | |||
Auto shutdown individual ports upon fault signals | |||
Auto-detection interval can be set | |||
Support STP/RSTP, Support MSTP | |||
Support IGMP snooping v1/v2/v3 | |||
Support static multicast groups | |||
Support DHCP client | |||
Support DHCP snooping | |||
Support DHCP relay option82 | |||
Support hierarchical management and password protection of users | |||
Support IEEE 802.1X authentication | |||
Support centralized MAC address based authentication | |||
Support traffic classification based on source MAC address, destination MAC address, source IP address, destination IP address, Layer 4 port, protocol type, VLAN, and so on | |||
Flow-based traffic rate limit | |||
Support flow-based priority tag | |||
Flow-based redirection of packets to another port | |||
Flow-based traffic statistics | |||
Support SP/WRR/SP+WRR queue scheduling | |||
Support flexible port mirroring, up to 4 port mirroring groups, monitoring network traffic by sending copies of all incoming and outgoing packets from the mirroring ports to a monitoring port. | |||
Support port traffic shaping | |||
Support congestion avoidance and drop policies | |||
Support locally / remotely management via CLI, SNMP, Web and Telnet, Console port | |||
Support Simple Network Management Protocol (SNMP) v1/v2/v3 | |||
Support Remote Monitoring (RMON) 1/2/3/9 groups of MIBs | |||
Support system log, hierarchical alarms | |||
Support SSH v2 | |||
Support power supply/fans/temperature of IC/ status detection and alarms | |||
Support Debugging Information Output | |||
Support remote maintenance through Telnet | |||
MIB | MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 | ||
Flow Control | IEEE 802.3x flow control, back pressure flow control | ||
Switch Properties | |||
Priority Queues | 4 | ||
MAC Table Size | 8K | ||
Max. Number of Available VLANs | 4094 | ||
VLAN ID Range | VID 1~4094 | ||
IGMP Snooping Groups | 256 | ||
Jumbo Frame Size | 16Kb | ||
Packet Buffer Size | 512Kb | ||
Interface | |||
Fiber Ports | 1000Base-X (SFP slot) | ||
RJ45 Ports | 10/100/1000BaseT(X) auto negotiation speed | ||
Console Port | RS-232 (RJ45 connector) | ||
Alarm Contact | 1 relay output with current carrying capacity of 1 A @ 24 VDC | ||
Button | Reset button | ||
LED Indicators | |||
System Led | SYS | ||
Interface indicator | SFP Ports: Link/ Act G1,G2,G3,G4 RJ45 Ports: LinkG5~G12, ActG5~G12 | ||
Power Led | PWR | ||
Power Requirements | |||
Input Voltage | 24VDC(12 to 36VDC),redundant dual inputs | ||
Connection | 6-contact terminal blocks | ||
No-load Power | 3.0W@24VDC | ||
Full Load Power | <0.24A@24VDC, <6W | ||
Overload Current Protection | Present | ||
Reverse Polarity Protection | Present | ||
Redundant protection | Present | ||
Physical Characteristics | |||
Housing | IP40 protection, High strength aluminium profile | ||
Installation | DIN-rail mounting, wall mounting | ||
Weight | 750g | ||
Dimensions(W x H x D) | 60.2 mm x 138.5mm x 112.5mm | ||
Environmental Limits | |||
Operating Temperature | |||
Standard Models | 0 to +60°C (32 to 140°F ) | ||
Wide Temp. Models | -40 to +75°C (-40 to 167°F) | ||
Storage Temperature | -40 to +85°C (-40 to 185°F ) | ||
Ambient Relative Humidity | 5 to 95% (non-condensing) | ||
Standards and Certifications | |||
Safety | UL 60950-1 | ||
EMI | FCC Part 15 Subpart B Class A, EN 55022 Class A | ||
EMS | EN 61000-4-2 (ESD) Level 4 EN 61000-4-3 (RS) Level 3 EN 61000-4-4 (EFT) Level 4 EN 61000-4-5 (Surge) Level 4 EN 61000-4-6 (CS) Level 3 EN 61000-4-8 Level 5 | ||
Shock | IEC 60068-2-27 | ||
Freefall | IEC 60068-2-32 | ||
Vibration | IEC 60068-2-6 | ||
Warranty | |||
Warranty Period | 5 years | ||
Details | See | ||
Certifications | |||
CE,FCC,RoHS,UL508(In authentication) | |||
Please check InMax’s website for the most up-to-date certification status. | |||
Ordering Information | |||
Available Models | SFP Transceiver Type | Connector Type | Temperature Range |
i712A | 2Km Dual-fiber MMF1310nm | SFP | -40°C to +85°C (-40 to 185°F ) |
20Km Dual-fiber SMF1310nm | |||
40Km Dual-fiber SMF1310nm | |||
60Km Dual-fiber SMF1310nm | |||
80Km Dual-fiber SMF1550nm | |||
120Km Dual-fiber SMF1550nm | |||
20Km-120Km BiDI SMF1310nm 20Km-120Km BiDI SMF1550nm | |||