BIOBASE Class II A2 Cytotoxic Safety Cabinet for lab
USD $1 - $6,000 /Unit
Min.Order:1 Unit
Zhangqiu Meihua International Trading Co., Ltd.
CE and SGS certified Class III Biological safety Cabinet BSC-1500IIIX
(BYKG-I/BYKG-II) Biobase Class I Biosafety Cabinet with CE skype: llqgrass
Biological safety cabinet Class II A2 Cabinet,NSF certificate
Biological Safety Cabinet/Biohazard Safety Cabinet (Class II A2)
4 feet Biological Safety Cabinet Class II,CE mark, large LCD display
Cytotoxic Satety Cabinet is the premium solution for cytotoxic/antineoplatic drug processing, providing the highest level of patioent, pharmacist and environmental protection.
Advantage:
1. Remote control. The operator need not to contact the biological safety cabinet directly, it's favorable for preventing cross contamination. It also makes the control operation much easier and convenient.
2. Work area surrounded by negative pressure.
3. Timer function
4. Large LCD display
5. Filter life inquiry
6. Motor control front window
According to the performance criteria:
1 Us standard ANSI/NSF49: 2002
2 European standard en12469: 2000
3 Chinese standard yy0569-2005
Certificates:
ISO9001, ISO14001, ISO13485
Model | 11234BBC86 | |
Normal size | 1.2 meter( 4' ) | |
External Dimensions (W x D x H) | 1370 x 760 x 2100 mm 53.9" x 29.9" x 86.6" | |
Internal Work Area, Dimensions (W x D x H) | 1220x600x630mm 48' ' x23.6' ' x24.8' ' | |
Internal Work Area, Space | 0.73 m2 | |
Average Airflow Velocity | Inflow | 0.46 m/s |
Downflow | 0.33 m/s | |
safety opening height | 200mm | |
max opening | 400mm | |
front window | two-layer laminated toughened glass > 5mm | |
Noise | < 62dB | |
Power | < =700W | |
water and gas tap | water tap: 1 gas tap: 1 | |
waterproof socket | 2 | |
Display | LCD display | |
Exhaust Volume with Thimble Duct | CBV Exhaust Volume | 611 m3 / h (360 cfm) |
Static Pressure at CBV Exhaust Volume | 39 Pa / 0.15 in H2O | |
air supply filter | ULPA filter, efficiency > 99.999% for particle size between 0.1 to 0.2 microns | |
exhaust filter | 2 pieces ULPA filter, efficiency > 99.999% for particle size between 0.1 to 0.2 microns | |
1000 Lux " > > 1000 Lux | ||
Fluorescent Lamp | 28Wx2 | |
UV | 30Wx1 | |
material | work area: 1.5mm 304 stainless steel, body: cold-rolled steel sheets with electrostatic coating | |
Net Weight | 380 kg | |
Shipping Weight | 400 kg | |
Shipping Dimensions, Maximum (W x D x H) | 1570 x 950 x 2220 mm | |
Electrical | AC110-220V/50-60HZ | |
stand accessory | UV, fluorescent lamp, remote control, foot switch, 2xwaterproof sockets |
Contact: Helen Li