FLS2-700 High Resolution Capacity Fuel Level Sensor measuring level sensor
USD $10 - $70 /Piece
Min.Order:1 Piece
Beijing Hengtop Technology Co., Ltd.
FLS2-700 Real Time Auto Tank/Pool/Gasoline Pump/Fuel Storage Level Detection Level Sensor
FLS-700-H high resolution industrial gps tracking fuel level sensor 0-5v factory
FLS-700-H high resolution industrial capacitive water level sensor RS485 factory
FLS2-700 high resolution fuel level transmitter for GPS tracking system factory
FLS2-700 high resolution oil level sensor for GPS tracking system factory
FLS2-700 high resolution industrial water flow meter for GPS tracking system factory
FLS2-700 High Resolution Capacity Fuel Level Sensor measuring level sensor
1. New fuel level sensor
2. High precision
3.Output: 0.5 ~ 4.5V, 0~5V, can be customized;
Applications
Fuel level sensor / water level sensor / level / indicator / probe / transducer / gauge / needle / transmitter / stick
Capacitance fuel Sensor / Capacitance Pressure Transducer / Capacitance Pressure Transmitter
Oil level measuring for automobile oil tanks, tankers and oil depots
Liquid level measurement / Anti fuel theft / fuel consumption management / liquid level sensing
Water, fuel, liquid tank level sensor / sensing
Unique Features
Introduction
The level sensor enjoy multi-innovation technologies, with capacitance as the sensitive element, GB sensor series continuous detects the height of the fuel level with less than 1mm resolution. Sensor length can
also be shorter to fit tanks with different heights. GB sensor can replace the original fuel level sensor on vehicles and connects with oil gauge. With wide range of voltage input, it has no limitation to input voltage.
Main Features
Spcification
Power supply | 10-32V |
Output | 0.5 ~ 4.5V, 0~5V, RS232,can be customized; |
Resolution | ≤1mm |
Operational Temperature | - 40 ~ +85°C |
Impurity filter | Helps to minimize grease and |
Compatible Medium | Diesel, biodiesel, gasoline, kerosene (Not applicable to conducting medium) |
Sensor length | 10-150cm |
Signal refreshing rate | 5s each time (Custom) |
Maximum operating current | < 15mA |
Protection rank | IP65 |
Mode of connection | Pin1: VCC; Pin5:Connect to calibrator; |
Tips on calibaration:
1. Calibrator:
Calibrator must couple with the sensor, and it has 12V/ 23A battery inside.
Red light is the power light. If the light isn't on when switch on, battery replacement is needed;
Green light is the calibration light. Full/ Empty button is showed in above picture.
Note: Calibration is necessary before using the sensor due to different fuel types;
2. Length adjustment and Calibrator:
2.1 Adjustment of sensor length
Aluminum tube at the bottom can be shorter according to different requirements from customers. Steps are as follows:
2.1.1 Customer specifies the sensor length according to the needs;
2.1.2 Cut the unwanted part with steel saw;
2.1.3 Get rid of the burrs and the debris at the cutting area with blade or a
screwdriver to avoid short circuit.
2.1.4 Take down the filter unit, take out the plug, and assemble the plug in the aluminum tube, then assemble the filter.
3. Calibration of the fuel level sensor
Calibration of the fuel sensor is calibration of the full level and empty level. The fundamental principle is to record a full value and empty value in the fuel sensor when tank is full and empty; defining the positions of fuel is full and empty in the tank. The electrical signal changes as the fuel level changes, calculating the height of the fuel level.
Note: when the fuel sensor becomes shorter, it shall be recalibrated. Calibration to empty level and full level is related to the medium and the fuel level, instead of volume of the tank, so this operation can be operated in room (make a container, full filled with diesel,simulation of the tank). Calibration of full level shall go first, then the empty level, or else, it is impossible for the sensor to enter thesetting mode.
4. Calibration of full level
Full fill the tank, put sensor into the tank, wait for about 30s till the aluminum tube of the sensor is full of fuel, then press the “full” button on the calibrator for 5 seconds till the green LED light slowly flickers, it indicates that calibration enters full level mode. The green LED light is off after about 10 seconds and it indicates that the calibration of the full level is OK.
5. Calibration of the empty level
Take the sensor out of the tank; put it outside of the tank. When all the fuel flows out of the sensor, press the “empty” button for 5 seconds till the green LED light flickers fast, it indicates that calibration enters empty level mode. The green LED light is off after about 10 seconds and it indicates that the calibration of empty level is OK.
6. Calibration completion
Disconnect the calibrator after calibration is done. Connect Pin 1 and Pin 3 on sensor with power, calibration becomes effective when sensor is power on.
Note: If press the wrong button during operation, you can switch off the calibrator and exit the mode and readjust.
7. Inspection
When calibration of the full level and empty level is done, inspect the output signal of the sensor:
Full level: V out is 5V
1/2 level: V out is 2.5V;
Empty level: V out is 0V.
If the output signal meets the values listed above, it means calibration is OK and normal operation of the sensor. Otherwise, please check the mode of connection and recalibrate it.
After Sale Service Of Sensor
Our Company