Specifications
S-35 35W 5V 7A LED Single Output Switching Power SupplyHigh reliability, Low price; high quality, better heat hink effect
S-35 35W 5V 7A LED Single Output Switching Power Supply S-35-5
1.CE Approved.
2.100% full-load burn-in test
3.Built-in EMI filter,a very small ripple
- S-35 series switch power supply
- Competitived price and high reliability
- 105 Output capacitor
- AC input power suitable for the world
- High efficiency and low operation temperature
- Soft-start current can reduce the AC input impact effciticly
- With short-circuit and overload protection
- Compact size, light weight
- 100% full-load burn-in test
- Installed with EMI filter, minimum wave
Model | S-35-5 | S-35-12 | S-35-15 | S-35-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage rang(Note:2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 7A | 3A | 2.4A | 1.5A |
Output current range | 0-7A | 0-3A | 0-2.4 | 0-1.5A |
Wave and noise(Note:3) | 75mVp-p | 100mVp-p | 101mVp-p | 100mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 35W | 36W | 36W | 36W |
Efficiency | 70% | 76% | 78% | 78% |
Adjustale range for DC voltage | +10,-5% | +10% | +10% | +10% |
Input current | 0.5A/115V 0.25A/230V | |||
AC Inrush current | Cold-start current 15A/115V 30A/230V | |||
Leakage current | <0.5mA/240VAC | |||
Overload protection | 105%~150% Type: pulsing hiccup shutdown Reset: auto recovery | |||
Temperature coefficient | ±0.03%/°c(0~50°c) | |||
Setup, rise, hold up time | 200ms, 100ms, 30ms | |||
Vibration | 10-500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||
Withstand voltage | Input and output internal 1.5KVAC, Input and enclosuer 1.5 KVAC, Output and enclosuer 0.5 KVAC | |||
Working temperature and humidity | -10°c~+60°c (Refer to output derating curve) 20%~90% RH | |||
Store temperature and humidity | -20°c~+85°c, 10%~95%RH | |||
Weight | 0.4Kgs | |||
Satety standards | Meet UL 1012 requirement(Not apply for the mark) | |||
EMC standards | Meet FCC aprt 15 J Conduction class B | |||
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25oC 70%RH.Temperature. 2. Error. include the setting error, line stability and load stability. (Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%. 6. Total output canbe maximum Current, total load can not exceed the maximum output power. |