96*96 three phase lcd digital display reactive smart energy meter RH-3RE31
Negotiable /Piece
Min.Order:10 Pieces
Zhejiang Kenaida Pushbutton Co., Ltd.
96*96 SINGLE-PHASE AC VOLTAGE LED DIGITAL COMBINATION METER RH-UI32
96*96 SINGLE-PHASE THREE ROW AC VOLTAGE FREQUENCY LED DIGITAL COMBINATION METER RH-UIF33
96*96 THREE-PHASE THREE ROW AC VOLTAGE AND FREQUENCY LED DIGITAL COMBINATION METER RH-3UIF33
96*96 THREE-PHASE THREE ROW AC VOLTAGE LCD DIGITAL COMBINATION METER RH-3UI3Y
96*96 THREE-PHASE THREE ROW AC VOLTAGE LED DIGITAL COMBINATION METER RH-3UI33
96*96 THREE-PHASE THREE ROW AC VOLTAGE AND FREQUENCY LCD DIGITAL COMBINATION METER RH-3UIF3Y
Description:
Intelligent digital instrument be used in electricity grids , automation control system to measure voltage ,current ,active power,reactive power , apparent power, power factor and frequency.They are displayed by LED or LCD. Visual display , High accuracy, Reliable performance, Strong isolation, Anti-Vibration.
Performance Characteristics
High-precision measure single-phase active power, single-phase reactive power, three-phase active power, single-phase reactive power
LED or LCD display , Local data query
Current and Voltage Conversion Ratio is programmable.
Support RS-485 communication Modbus-RTU treaty.
Support DI DO
Auxiliary Power Supply :AC/DC 80V-270V, AC220V,AC380V,AC100V
Various shape can be choosed.
Accuracy of measurement | |
Active power | 1.0 degree |
Reactive power | 2.0 degree |
Signal Input | |
Mode of connection | single-phase ,three-phase three-wire,three-phase four-wire |
Rated voltage | AC57.7V ,AC 100V,AC220V,AC380V |
Rated current | AC1A ,AC5A |
Overload | Voltage:1.2 times 2 times /1 second(instantaneous) |
Current:1.2 times 10 times /5 second(instantaneous) | |
Power dissipation | Voltage:less than 1VA/phase ;Current :less than 0.4VA/phase |
Impedance | Voltage:more than 300kΩ:Current:Less than 20mΩ |
Frequency | 45-65Hz |
APS | |
Operating Range | AC/DC 80V-270V ,AC220V,AC380V,AC100V,DC48V,DC24V |
Power dissipation | Less than 4VA |
Function Module | |
Communication interface | No. 1 RS-485 communications,Modbus-RTU treaty |
Baud rate:1200-9600bps ,the default value is 2400bps | |
DI | support 4 dry contacts |
DO | support 3 relay output,capacity AC250V/5A DC30V5A |
Environment | |
Working environment | -10°C- +55°C |
Storage Temperature | -25°C- +70°C |
Relative Humidity | ≤93%, No corrosive gas places |
Altitude | ≤2500m |
Security | |
Insulation Resistance | >100mΩ |
ACW | AC 2KV |
EMC | |
ESD | grade 4 |
EFT | grade 4 |
Surge impact | grade 4 |
Dimension | |
Frame dimension | 120*120; 80*80; 96*48; 96*96; 80*80; 48*48; 120*60; 160*80 |
Hole dimension | 111*111; 76*76; 92*45; 92*92; 68*68; 45*45; 114*56; 152*76 |
Model | Measurement | Extended Function | LED | LCD | Hole dimension | |||||
Electric Energy | DI | DO | TO | Communication interface | ||||||
RH-E11 | Single-phase active power | 2 | 2 | 1 | 1 | √ | 152*76 | |||
RH-E21 | Single-phase active power | 2 | 2 | 3 | 1 | √ | 111*111 | |||
RH-E31 | Single-phase active power | 2 | 2 | 3 | 1 | √ | 92*92 | |||
RH-E41 | Single-phase active power | 2 | 2 | 3 | 1 | √ | 114*56 | |||
RH-E51 | Single-phase active power | 2 | 2 | 3 | 1 | √ | 92*45 | |||
RH-E61 | Single-phase active power | 2 | 2 | 1 | 1 | √ | 68/*68 | |||
RH-E71 | Single-phase active power | 2 | 2 | 1 | 1 | √ | 76*76 | |||
RH-E81 | Single-phase active power | 2 | 2 | 1 | 1 | √ | 45*45 | |||
RH-3E2Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 111*111 | |||
RH-3E3Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 92*92 | |||
RH-3E6Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 68*68 | |||
RH-3E7Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 76*76 | |||
RH-3RE2Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 111*111 | |||
RH-3RE3Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 92*92 | |||
RH-3RE6Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 68*68 | |||
RH-3RE7Y | Three-phase active power | 2 | 2 | 1 | 1 | √ | 76*76 |
24.TRI-PHASE REACTIVE ENERGY MRTER | ||||
Model | Display Mode | Face Frame Size | Hole Size | |
mm | mm | |||
RH-3RE11 | LCD | 160*80 | 152*76 | |
RH-3RE21 | LCD | 120*120 | 111*111 | |
RH-3RE31 | LCD | 96*96 | 92*92 | |
RH-3RE41 | LCD | 120*60 | 114*56 | |
RH-3RE51 | LCD | 96*48 | 92*45 | |
RH-3RE61 | LCD | 72*72 | 68*68 | |
RH-3RE71 | LCD | 80*80 | 76*76 |
Terminal diagram
The wiring diagram