Portable Vacuum Cavitation Slimming Machine Weight Loss With Multipolar RF Liposuction BD-BZ010 Cavitation Rf Slimming Machine
USD $630 - $730 /Set
Min.Order:10 Sets
Guangzhou Bangde Beauty Equipment Co., Ltd.
Vacuum Bipolar RF
For body and face re-shaping. Weight loss Vaccum+RF fat-explosion function can promote tissue metabolism,repel the cellulite, which make fat granule in different depths and shocking make fusion energy, and the deepest receptor can get granule in 3CM thick of skin, and rapid expansion and the rapid heating of the cell wall that exceed the elastic limits and arises cells broken, so that the combustion of fatty acids at the same time broken out of a pot, not only the burning consumption of fatty acids but also more directly emptying so rapidly reduce the size of granule.
40K Cavitation Strong sound wave systemMultipolar RFTripolar RFLCD touch screen
♥ 40K Strong sound waves explosion head effectively promote the organization fat metabolism, repel orange peel fat, firming skin, enhancing skin elasticity, etc. And the effect is long lasting. The 40 K sound waves can make a implosion of liquid as the expansion and compression of the wave make the inside of the liquid formed in many small space and what inside this kind of space are gas and steam. Inside of the low density fat cells, the cohesiveness of the molecular is weaker. The low negative pressure which is produce by 40 K sound waves will produce organization gap which is called "cavitation phenomenon" in physics. The implosion of inside and outside of the cells will enhanced the molecular motion and achieve a high energy level, and eventually led to the bursting of the fat cells.
Caution for Using 40K Cavitation
1.Applied enough gel on skin need treated.
2.Do not stay unmoved on any part of your body ,do not stay on bones.
3.The total treatment time for daily should be within 30 minutes.
4.There will be ultrasonic only when you step on the service brake while using 40K cavitation explode work head.
5.Do not allowed to be placed under the state of no-load to avoid the damage caused by high heat.
6.40K work head can be used on fresh part of the body, Do not use for facial. If the skin is sensitive or becomes unhealthy, the strength of the power should be adjusted down.
Principle of Multipolar Circulation
♥ Skin rejuvenation principle
The circulation medical radio frequency system in 1 seconds will change the electric polarity in electric field millions timesof the biological tissue of the therapeutic part , particles of the organization will do Brownian motion(molecular no rules movement) as the same frequency which will make the organization produce columnar distribution of heat, damage collagen hydrogen bonding structure and change the collagen molecules of the three spiral structure, and lead to the immediate collagen sex contraction and as a result of the treatment effect of firming skin;
According to ajusting the energy output, the circulation system makes skin tissues have mild, moderate and severe heat aggression three stages which is similar as the three stages in wound healing (inflammation stage, growth stage, remodeling stage), improve leather remodeling shape,so as to reconstruct the skin and dispel light, medium, heavy wrinkles uteruses Calvin lines and the r skin flabby after losing weightThe effect is long lasting.
♥ De-fatting body slimming principle How does RF works? The multi-polar radio frequency causes a reaction in the tissue which stimulates the body's natural healing response causing new collagen to form, and the production of new elastin fibres making skin to look and feel firmer. Skin is heated consistently and uniformly without the risk of any burns. How does Vacuum works? After break up the subcutaneous fat, decrease cellulite accumulation. It helps smooth lymph and discharges the fatty acid and toxin that is decomposed through lymph system. Vacuum hads immediate effect in body shaping.
The medical circulation rf system will produce columnar distributed hea in the subcutaneous tissue and fully make triglycerides release from the fat cells. Under the action of lipase the triglyceride will cracking into fatty acids and glycerin, then eliminated from the body along with the metabolism. Because of the intelligent system, the medical circulation rf instrument can orientate the fat cells, and release triglycerides quantificationally, thus achieved the localization, the effect of reducing weight rationally and quantificationally
Caution for using RF
1.Beautician should wear insulated gloves during operation.
2.Do not wear any aglet, both for the beautician and the users.
3.The electrode probe must be fully in contact with skin.
4.Do not make the RF electrode stay on any part without moving. Keep it moving on skin slowly.
5.Skin around eyes and forehead is very thin, the RF output intensity should be relatively weakened.
6.Do not contact skin with unipolar when using of bipolar, tripolar, hexpolar RF work head otherwise it will produce pulse discharge, gel paste etc. Products like gel maybe evaporated into a mist.
Accessories List
Mainframe | 1 pc |
Power line | 1 pc |
40K cavitation explode work head | 1 pc |
Hexpolar RF laser work head for body | 1 pc |
Tripolar RF work head for face | 1 pc |
Accssories bracket | 1 pc |
User manual | 1 pc |
RF radio frequency slimming machine is applied to:
Sculpture
Fat removal
Radio frequency slimming
Make the pores contracted
Increase blood circulation
Face lifting
Improve lymph drainage
Guangzhou Bangde Beauty Equipment Machine
Technology Explanation
High Intensity Focused Ultrasound penetrates focused and volumetric ultrasonic energy at precise depth (1.2 cm) in subcutaneous fat layers targeting fat tissue causing a non-thermal effect. The surrounding structures such as the epidermis, blood vessels and nerves will not be damaged. Meanwhile the metabolized contents (triglyceride, fatty acid) of cells will excrete outside body automatically through blood circulation and lymphatic drainage without harm to the human body.