2.5MM2 BV single core electrical cable use in building
USD $0.1 - $99 /Meter
Min.Order:5000 Meters
Shenzhen Jixing Electric Wire & Cable Co., Ltd.
Standard
The cable is manufactured according to GB5023-2008 and JB8734-1998 national standard
or international standard of 60227IEC.
Application
The cables can be applied to the copper(aluminum)-core cables in the rated A/C voltage of
U/U450/750V and the below power, lighting, daily electric appliances, apparatus and
telecommunication equipments.
Operation characteristics
1-U0/U is 450/750V and 300/500V ;
2-The allowed long-term working temperature of wire should not exceed 70°C;
The cable (wire) shall be installed at temperature not lower than 0°C;
3-The bending radius shall not be less than 4D of the cable overall diameter it is less
25mm; the bending radius shall not be less than 6D of cable overall diameter when it
is more than25mm.
Manufacture length
1-The coil length of cable (wire) shall be 100M, filled reel length shall be more than 1000M;
2-The short cable are permitted with a length not less than 10m for each and their quantity
shall not exceed 10% of the total supply length, and short length quantity of every piece
not more than 2pcs;
3-Any supply length is permitted based on the agreement with buyer. The error of metering
shall not exceed ±0.5%.
Type | Description | Specification | |||||
Rated voltage (V) | No. of cores | Nominal cross-sectional area (mm2) | |||||
BV | Cu conductor PVC insulated cable(wire) | 300/500 | 1 | 0.75-1 | |||
227 IEC 01(BV) | Single-core hard conductor non-sheathed cable(wire) | 450/750 | 1 | 1.5-400 | |||
BV 300/500V Cu conductor PVC insulated cable (wire) | |||||||
Nominal cross-sectional area (mm2) | Construction of conductor (No. of wires) | Insulation thickness (mm) | Max Outer diameter (mm) | Max. D.C. resistance at 20°C (Ω/km) | Min Insulation resistance at 70°C (MΩ/km) | Current rating in air at 25°C (A) | Approx. Weight of cable (kg/km) |
0.75 | 1 | 0.6 | 2.4 | 24.5 | 0.012 | 13 | 10.9 |
1.00 | 1 | 0.6 | 2.7 | 18.1 | 0.013 | 20 | 11.5 |
227 IEC 01(BV)450/750V Single-core hard conductor non-sheathed cable(wire) | |||||||
Nominal cross-sectional area (mm2) | Construction of conductor (No. of wires) | Insulation thickness (mm) | Max Outer diameter (mm) | Max. D.C. resistance at 20°C(Ω/km) | Min Insulation resistance at 70°C (MΩ/km) | Current rating in air at 25°C (A) | Approx. Weight of cable (kg/km) |
1.5 | 1 | 0.7 | 3.3 | 12.1 | 0.011 | 25 | 19.9 |
2.5 | 1 | 0.8 | 3.9 | 7.41 | 0.01 | 34 | 31.4 |
4 | 1 | 0.8 | 4.4 | 4.61 | 0.0085 | 44.5 | 46.3 |
6 | 1 | 0.8 | 4.9 | 3.08 | 0.007 | 58 | 66 |
10 | 7 | 1.0 | 6.4 | 1.83 | 0.007 | 79.5 | 116 |
16 | 7 | 1.0 | 8 | 1.15 | 0.005 | 111 | 175 |
25 | 7 | 1.2 | 9.8 | 0.727 | 0.005 | 146 | 275 |
35 | 7 | 1.2 | 11 | 0.524 | 0.004 | 180 | 372 |
50 | 19 | 1.4 | 13 | 0.387 | 0.0045 | 225 | 496 |
70 | 19 | 1.4 | 15 | 0.268 | 0.0035 | 280 | 701 |
95 | 19 | 1.6 | 17 | 0.193 | 0.0035 | 344 | 969 |
120 | 37 | 1.6 | 19 | 0.153 | 0.0032 | 397.5 | 1202 |
150 | 37 | 1.8 | 21 | 0.124 | 0.0032 | 455 | 1478 |
185 | 37 | 2.0 | 23.5 | 0.0991 | 0.0032 | 519 | 1853 |
240 | 61 | 2.2 | 26.5 | 0.0754 | 0.0032 | 541 | 2417 |
300 | 61 | 2.4 | 29.5 | 0.0601 | 0.003 | 636 | 3024 |
400 | 61 | 2.6 | 33.5 | 0.047 | 0.0028 | 727 | 3825 |
Certification:
Packing Picture: