HK-STM-1 Krebs Stormer Viscometer
USD $1,000 - $1,001 /Set
Min.Order:1 Set
Liaoning Huake Petroleum Apparatus Science & Technology Co., Ltd.
HK-STM-1 Krebs Stormer Viscometer
Overview
HK-STM-1 conforms to ASTM D562 Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer. This apparatus covers the measurement of Krebs Unit(KU) viscosity to evaluate the consistency of paints and related coatings using the Stromer-type viscometer. HK-STM-1 simplifies an established test procedure providing an immediate calculation of the viscosity value.
Features
1.Easy to use- no weights or stroboscopic timing attachment
2.Switch selectable LED digital display of Krebs units or grams or centipoise
3.Allows for rapid and easy measurement of samples
4.Humanization design, synchronous display temperature and viscosity value
5.Manual lift design, reduce the testing interface control requirement
6.As for thixotropy non-Newton liquid, the timing function of the apparatus can guarantee the obtaining of good conforming data.
7.Step motor adopts high sub-division driver with high precision and stable operation. The changing frequency of alternating voltage will not affect the precision.
Technical parameter
1.Measuring range: 40KU—141KU,32g—1099gm(Loading value),27—5,274cp
2.Measurement accuracy:±1%(Full scale)
3.Measuring repeatability: ±0.5%(Full scale)
4.Rotor speed: 200 RPM (±0.01RPM)
5.Measuring container: 1pint, 0.5pint
6.Input voltage: 110V/220V
7.Input frequency: 50Hz/60Hz
We can provide varies kinds of ASTM thermometers and capillary viscometers for this kinematic viscometer apparatus. See detailed information as below form:
Cannon-Fenske Opaque Viscometers
Size | Approx. constant, mm2/s2(cSt/s) | Kinematic Viscosity Range mm2/s(cSt) |
25* | 0.002 | 0.5 - 2 |
50 | 0.004 | 0.8 - 4 |
75 | 0.008 | 1.6-8 |
100 | 0.015 | 3-15 |
150 | 0.035 | 7-35 |
200 | 0.1 | 20-100 |
300 | 0.25 | 50-250 |
350 | 0.5 | 100-500 |
400 | 1.2 | 240-1200 |
450 | 2.5 | 500-2500 |
500 | 8 | 1600-8000 |
600 | 20 | 4000-20000 |
650 | 45 | 9000-45000 |
700 | 100 | 20000-100000 |
Cannon-Fenske Routine Viscometers
Size | Approx. constant, mm2/s2(cSt/s) | Kinematic Viscosity Range mm2/s(cSt) |
25* | 0.002 | 0.5 - 2 |
50 | 0.004 | 0.8 - 4 |
75 | 0.008 | 1.6-8 |
100 | 0.015 | 3-15 |
150 | 0.035 | 7-35 |
200 | 0.1 | 20-100 |
300 | 0.25 | 50-250 |
350 | 0.5 | 100-500 |
400 | 1.2 | 240-1200 |
450 | 2.5 | 500-2500 |
500 | 8 | 1600-8000 |
600 | 20 | 4000-20000 |
650 | 45 | 9000-45000 |
700 | 100 | 20000-100000 |
Ubbelohde Viscometers
Size | Approx. constant, mm2/s2(cSt/s) | Kinematic Viscosity Range mm2/s(cSt) |
0* | 0.001 | 0.3 -1 |
0C | 0.003 | 0.6 - 3 |
0B | 0.005 | 1-5 |
1 | 0.01 | 2-10 |
1C | 0.03 | 6-30 |
1B | 0.05 | 10-50 |
2 | 0.1 | 20-100 |
2C | 0.3 | 60-300 |
2B | 0.5 | 100-500 |
3 | 1.0 | 200-1000 |
3C | 3.0 | 600-3000 |
3B | 5.0 | 1000-5000 |
4 | 10 | 2000-10000 |
4C | 30 | 6000-30000 |
4B | 50 | 10000-50000 |
5 | 100 | 20000-100000 |
Thermometer
Item | Division Value(℃) | Thermometer Range(℃) | Size | Length(mm) | OD(mm) | Immersion (mm) |
28C* | 0.05 | 36.4-39.4 | Stick | 305±5 | 6.0-8.0 | Full |
29C | 0.05 | 52.6-55.4 | Stick | 305±5 | 6.0-8.0 | Full |
44C | 0.05 | 18.6-21.4 | Stick | 305±5 | 6.0-8.0 | Full |
45C | 0.05 | 23.6-26.4 | Stick | 305±5 | 6.0-8.0 | Full |
46C | 0.05 | 48.6-51.4 | Stick | 305±5 | 6.0-8.0 | Full |
47C | 0.05 | 58.6-61.4 | Stick | 305±5 | 6.0-8.0 | Full |
48C | 0.05 | 80.6-83.4 | Stick | 305±5 | 6.0-8.0 | Full |
110C | 0.05 | 133.6-163.4 | Stick | 305±5 | 6.0-8.0 | Full |
118C | 0.05 | 100-500 | Stick | 305±5 | 6.0-8.0 | Full |
120C | 0.05 | 38.6-41.4 | Stick | 305±5 | 6.0-8.0 | Full |
121C | 0.05 | 98.6-101.4 | Stick | 305±5 | 6.0-8.0 | Full |
129C | 0.05 | 91.6-94.4 | Stick | 305±5 | 6.0-8.0 | Full |
132C | 0.05 | 148.6-151.4 | Stick | 305±5 | 6.0-8.0 | Full |