SELON ACID CONCENTRATION METER,DIGITAL PH METER,PH METER DIGITAL
USD $587 - $587 /Piece
Min.Order:1 Piece
Shanghai Selon Scientific Instrument Co., Ltd.
TEL: +86 21 65416501 FAX: +86 21 35100022 SKYPE: selon-group
SELON ACID CONCENTRATION METER,DIGITAL PH METER,PH METER DIGITAL
endress hauser , marks and spencer , hydroponic aquarium
pH Mode:
*During the pH mode, Up to 5 points push-button calibration with auto-buffer recognition.
*Selectable pH buffer standards and resolution (0.1, 0.01, 0.001pH).
*Automatically calculates and displays electrode slope that helps you decide whether to replace pH electrode.
ORP Mode:
*Single point offset calibration allows user adjusts displayed value to a known standard.
*Absolute or Relative mV measurements provides accurate readings.
Ion Mode:
*Standard BNC connector can connects many Ion Selective Electrode.
*2 to 5 points push-button calibration from low to high concentrations.
*Selectable multiple concentration units,including ppm, mg/L, mol/L.Direct readout ion concentration simplifies measurement process.
*mV measurement allows user to check performance of ion electrode.
Conductivity Mode:
*Up to 5-point push-button calibration allows user to uses customized calibration solutions.
*Adjustable TDS factors, cell constants, temperature coefficients and normalization temperature (20°C or 25°C).
*Selectable linear or pure water compensation modes.
*In salinity measurement modes,selectable practical salinity (PSU) or seawater measurement standard (ppt).
Dissolved Oxygen Mode:
*1 or 2 points auto-calibration (100% in saturated air or air-saturated water, 0% in zero oxygen solution).
*Manual salinity and barometric pressure compensation.
*Selectable readout in ppm, mg/L or % saturation.
Bante900 multi-parameter meter is capable of measuring up to 9 water quality parameters, including pH, ORP, Ion, Conductivity,TDS, Salinity, Resistivity, Dissolved Oxygen, etc.
General Features:
Automatic Temperature Compensation ensures high accuracy of measurements.Calibration due reminder helps you to calibrate meter regularly.Automatic endpoint function freezes stable measured values. Help message as a operational guide to helps you understand how to use meter.Setup menu lets user customize the calibration points, stability conditions, date and time to meet measurement requirements.Expanded memory stores and recalls up to 500 readings.Built-in real-time clock stamps stored data to meets GLP.USB communication interface.
Specifications:
Model: Selon900
pH Range:-2.000~20.000pH
pH Accuracy:±0.002pH
Resolution:0.001, 0.01, 0.1pH, Selectable
Calibration Points:Up to 5 points
Calibration Solutions:USA(pH1.68/4.01/7.00/10.01/12.45), NIST(pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/ 12.75)
Ion Concentration Range:0.001~19999ppm, mg/L, mol/L (Depending on measuring range of Ion Selective Electrode)
Ion Concentration Accuracy:±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)
Calibration Points:2 to 5 points
Calibration Solutions:0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm
mV Range:-1999.9~1999.9mV
mV Accuracy:±0.2mV
Resolution:0.1, 1mV, Selectable
Conductivity Range:0~20mS/cm (Max.200mS/cm)
Conductivity Accuracy:±0.5% Full Scale
Calibration Points:Up to 5 points
Calibration Solutions:10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
TDS Range:0~10ppt (Max. 20ppt, Depending on factor setting)
TDS Accuracy:±1% Full Scale
TDS Factor:0.1~1.0 (Default 0.5)
Salinity Range:0~10ppt (Max.80ppt)
Salinity Accuracy:±1% Full Scale
Salinity Measurement Modes:Practical Salinity (PSU) or Seawater Measurement Standard (ppt)
Resistivity Range:0~100MΩ
Resistivity Accuracy:±1% Full Scale
Resolution:0.001, 0.01, 0.1, 1, Automatic
Temperature Coefficient:0.0~10.0% per °C
Compensation Modes:Linear or Pure Water
Cell Constant:K=0.1, 1, 10, Selectable
Normalization Temperature:20°C or 25°C
Dissolved Oxygen Range:0.00~20.00mg/L or ppm
Resolution:0.01mg/L
Dissolved Oxygen Accuracy:±0.2mg/L
% Saturation of Oxygen:0.0~200.0%
Accuracy:±2.0%
Salinity Correction:0~50g/L
Pressure Correction:60.0~112.5kPa, 450~850mmHg
Temperature Range:0~105°C, 32~221°F
Temperature Accuracy:±0.5°C, ±0.9°F
Temperature Calibration:Manual
Temperature Compensation:0~100°C, 32~212°F, Automatic or Manual; DO Mode: 0~50°C, 32~122°F, Automatic
Auto-Off:Manual or Automatic (10, 20, 30 minutes after last key pressed, Selectable)
Hold Function:Manual or Automatic endpoint
Stability Conditions:Low or High, Selectable
Calibration due reminder:1 to 30 days or Off
Reset Function:Yes
Memory:500 data sets with Date/Time stamping
Output:USB Communication Interface
Connector:BNC and 6-pin connector
LCD Display:Custom dual-display LCD (130×110mm)
Power Requirements:DC5V, using AC adapters, 220VAC/50Hz
Dimensions:210(L)×188(W)×60(H)mm
Weight:1.2kg
Payment Terms
1. All the payments required before
2.30% deposit required before production, 70% balance before delivery.
ph and conductivity meter , Multi-Parameter Water Quality Meter , ORP Meter