SELON PBC96 SAMPLE CONCENTRATOR
USD $690 - $690 /Unit
Min.Order:1 Unit
Shanghai Selon Scientific Instrument Co., Ltd.
SELON PBC96 SAMPLE CONCENTRATOR
vitamin concentrate
sample concentrator
gold concentrates for sale
Technical Parameters
Model | PBC96 96 holes nitrogen concentrator |
Temperature range | RT+5°C to 150°C |
Heating time | ≤30min (40°C-150°C) |
Temperature accuracy(40~100°C) | ±0.5°C |
Temperature accuracy(100~150°C) | ±1°C |
Temperature uniformity(100°C) | ±0.5°C |
Blocks Quantity | 1 pieces |
Time range | 0.1 |
Nitrogen flow | 99h59min |
Nitrogen pressure | 0—10L/min |
power | ≤0.1MPa |
Dimensions | 200W |
Blocks Selection | 280x220x400 mm |
Temperature range | Refer to the “blocks replacement for PBC96 Series” |
Conventional configuration
The user can select the blocks from PB16 and PB17, blocks can be interchanged, and conventional configuration is PB06 blocks.
Blocks replacement for PBC96 Series
Type | Tube diameter | Tubes | Block size (mm) |
PB16 | 0.2ml centrifugal tube | 96 | 78 x 114 x 26 |
PB17 | Plate(no holes) | 96 hole enzyme plates | 81 x 123 x 19 |
PB16, PB17 is special configured for PBC96
Product Numbers: PBC96
Product description: PBC96 96 holes nitrogen concentrator is mainly used for enrichment of large-volume sample or preparation (such as drug screening, hormone analysis, liquid phase, and mass spectrometry in the analysis of sample preparation). Working principle: the nitrogen into the heated surface of the sample and make the solvent t evaporate and separated rapidly, thereby reaching the sample enrichment purpose without oxygen, keep the sample purer. Nitrogen concentrator instrument can concentrated dozens of samples simultaneously, saving time and high efficient, instead of rotary evaporation instrument
Product features
1, The heater allows samples to be heated rapidly to the evaporation temperature, through the gas blow to the solution surface via needle at the same time, prompting rapid evaporation and concentration solution.
2, The gas chamber height can be adjusted, the length of standard gas needle is 80 mm.
3, Each blow needle can be controlled independently, can be blown, separate flow regulation, no waste of gas.
4, The entire system can be arranged in the ventilation cabinet when process concentration of toxic solvents,
5, Built in over-temperature protection device, automatic fault detection and alarm function.
6, LED display, temperature and time diminishing display, the operation is simple and convenient.
7, configured standard gas chamber and special adjustable bracket.