Air Conditioning Thermal Insulation Pipe/ Tube Insualtion
Insulation Tube for ac
Application Home Type
Air Conditioning Rubber Insulation
Color Black
Tuber Insulation,Insulation Tube ,Pipe Insulation, Insulation Tube . Insulation Pipe . Tube Insulation.Insulation Board , Insulation Foam Board .
Quick Details
- Type: Air Conditioner Parts
- Application: Home
- Type: Air Conditioning Rubber Insulation Pipe Insulation Tube
- Certification: RoHS
- Place of Origin: China (Mainland)
- Brand Name: RETEK&BESTAR
- Model Number: Air Conditioning Rubber Insulation Pipe Insulation Tube
- Color: Black
- Material: Foam and Rubber
- Air conditioner rubber insulation tube:Closed cell pipe insulation
- Wall Thickness: 6-32mm
- Length: 6FT(1.83m)
- Density: 50-100KG/CBM
- Surface: smooth
- Rubber Insulation Tube,Insulating Tube,:Rubber Insulation Pipe
- ID Size: 1/4", 3/8", 1/2", 5/8", 3/4", 7/8", 1", 1-1/8",1-1/4",2-1/8",etc
- Rubber Plastic Thermal Insulation Pipe:Thermal Insulation Pipe,Rubber Plastic Insulation Pipe
Packaging Details: | simple packaging with opp bag , but we accept customized design package. |
Delivery Detail: | about 7 working days, according to the quantity |
We can supply many kinds of Air Conditioning Rubber Insulation Pipe Insulation Tube Insulation Hose ,
Rubber Insulation Tube,Rubber Insulation Pipe,Air Conditioner Insulation Pipe , Rubber Foam Insulation Tube ,
Rubber Insulation Tube,Insulating Tube,Rubber Insulation Pipe , Pipe Insulation Rubber Foam,
Pvc Pipe Insulation Foam,Air Conditioning Insulation Rubber Foam , Foam Pipe,Rubber Foam Pipe,Insulation Foam Pipe ,
Rubber Plastic Thermal Insulation Pipe,Thermal Insulation Pipe,Rubber Plastic Insulation Pipe , Air Conditioner Insulation Tube,
nsulation Tube,Air Conditioner Insulation Pipe.
Related Products:
Data
Item | Unit | Requirement | Standard | Actual Resault | |
---|---|---|---|---|---|
Density | Kg/M3 | ≤95 | GB/T 6343 | ≥43 | |
Flammability | Limited Oxygen Index | % | ≥32 | GB/T 2406 | 35 |
Smoke Density | - | ≤75 | GB/T 8627 | 8 | |
|
| Class 1 | BS 476 part 7 | Pass | |
Thermal Conductivity | −20°C | λ | ≤0.034 | GB/T 17794 | 0.031 at 0°C |
0°C | ≤0.036 | ||||
40°C | ≤0.041 | ||||
Water Vapor Permeability | Water Vapor Permeability | g/(m.s.pa) | 1.8≤ x ≤10-14 | GB/T 17146-1997 | 1.2 x 10-10 |
Moisture Resistance Factor | μ |
| 10000 | ||
Vacuum Water Absorption | % | ≤10 | GB/T 17794-2008 | 2 | |
Dimension Stability 105±3°C, 7 days | % | ≤10 | GB/T 8811 | 6.7 | |
Crack Resistance | N/cm | ≥2.5 | GB/T 10808 | 2.76 | |
Compression Resistance Ratio, | % | ≥70 | GB/T 6669-2001 | 94 | |
Compression Ratio 50%, | |||||
Compression Time 72 hours | |||||
Anti-Ozone | - | No Cracking | GB/T 7762 | Pass | |
Ozone Pressure 202 mpa, 200 hours | |||||
Aging Resistance, 50 hours | - | Slightly Crumpling, no cracks, no pin holes, no deforming | GB/T 16259 | Pass | |
Temperature Range | °C | −40 ~ 105 | GB/T 17794 | Pass |