CQ-X6 Coating Thickness Gauge & portable coating thickness gauge
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Handsome Technology Co., Ltd.
Coating Thickness Gauge & portable coating thickness gauge CQ-X6
Measuring range: 0 ~ 1250μm, 0 ~ 49 mils | Standard coating thickness ± (2μm + 3% H), H- measurement: accuracy |
Storage temperature: -10 ℃ ~ 60 ℃ | Operating temperature: 0 ℃ ~ 40 ℃ |
Probe: Built-in one probe | Power: 2 x 1.5V (AAA alkaline) |
Composite coating measurement for all metals. Depending on the substrate may be, each time the display readings, while the letter Fe (magnetic metals, such as iron, steel) or NFe (non-magnetic metal, such as aluminum alloy). Compound thickness can automatically identify the substrate.
Operating
Power reduction starts automatically start the measurement probe, still 30 seconds, the power is automatically turned off.
The probe is flat and measured thickness (coated) substrate surface, predict with confidence, when the measurement is completed, thickness tweet, pick gage readings are displayed. Out of range display symbol "- - - -."
CQ-X6 thickness, 1.8-inch TFT screen, also shows the maximum measurement process, minimum, average and error.
UVLED
Tap the "+" button once, open UVLED, and then tap the "+" button once, close UVLED.
LED
Tap the "-" button 1, turn on LED, then tap "-" button once closed LED.
Color conversion
Press "+" button for 2 seconds, can transform the display font color.
Is highlighted
Press "-" button for 2 seconds, can display 180-degree turn.
Unit switch
Tap "M" button 2 times, the buzzer sounds, complete the conversion "um" and "mil" between.
Calibration
a. uncoated calibration
Tap "M" button three times, the screen displays "00", the buzzer "beep, beep, beep ..." sound, this time, the gage probe flat on uncoated substrates tested surface, predict with confidence, thickness tweet, the screen displays "0", pick up the gauge, complete uncoated zero.
b. standard film calibration
Measurement standards slice, tap "M" button once, the buzzer "beep, beep", the current measurement data flash 2 times, then press "+" or "-" button to consistent readings raised the standard sheet Finally, the tap "M" button once, the buzzer "beep" once confirmed modify data.
c. Restore the factory parameters
Press the "+" or "-". "Beep, beep, beep" button, buzzer sound when you release the button to complete restore factory operations.
Clear the maximum, minimum, average and error values
Tap "M" button 4 times, the buzzer "beep" sound, clear maximum, minimum, average, and the measured error value.
Low battery alarm
When appears on the screen when "" the measured values may not be accurate, please replace the battery.