Bare Aluminum Conductor With Grease

Bare Aluminum Conductor With Grease

USD $0.1 - $5 /Ton

Min.Order:1 Ton

Supply Ability:
5000 Ton / Tons per Month
Port:
QingDao
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
HNTDDL
Model Number:
ACSR Conductors
Type:
Bare
Application:
Overhead
Conductor Material:
Other, aluminium & galvanized steel

Henan Tong-Da Cable Co., Ltd.

Business Type: Manufacturer,Trading Company
Luoyang Henan China
Main Products: Conductor ,Cable ,Wire

Product Details

Specifications

1.ISO9001 &ISO14001
2.25 years experience
3.long distance power transmission
4.good mechanical and electrical properties

ACSR brief introduction

 

The biggest ACSR conductor supplier for China State Grid.
Cheaper price&good quality
sales in America,Europe,Middle East

    Aluminum conductors, steel-reinforced for overhead power tranmission.
A conductor consisting of seven or more aluminum and galvanized steel wires built up in concentric layers, the center wire or wires are of galvanized steel and the outer layer or layers are of aluminum

     Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.

 

1. Specification:

(1) all aluminium conductor (AAC)

(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)

(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)

(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

 

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.

1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.

2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

 

3.Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

4.Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; "aluminized" aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

 

5.Specifications:

ACSR bare conductor meets or exceeds the following ASTM specifications:

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes

B-231 Aluminum Conductors, Concentric-Lay-Stranded

B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)

B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

 

6.Notes:

Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75centigrade conductor temperature, 25centigrade ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

ACSR

IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182,JIS C3110

AAC

IEC61089, BS215 part1, ASTM B231, DIN48201, JIS C3109, CSA C49

AAAC

IEC61089, BS 3242, ASTM B399, BS EN50183, DIN48201

ACS

ASTM B505, ASTM B416, DIN 48201

ACAR

ASTM B524, IEC 61089

AACSR

ASTM B711, DIN 48206, IEC 61089

We have attained ISO9001 & ISO14001 certificates.

 

 

 Bare Aluminum Conductor With Grease

Contact Supplier

Mr. Admin hntddl Chat Now
Telephone
86-371-60311151
Fax
86-371-60311150
Address
No.299 Jinshui Road Pufa International Finance Center Mansion 1203 Room,Zhengzhou City Henan Province China Zhengzhou Branch Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electrical Wires
Categories
Hi~