Aluminum Conductor Steel Reinforced ACSR Bare Conductor
USD $1 - $6 /Meter
Min.Order:1000 Meters
Detailed Product Description
a.High tensile strength
b.Long life
c.Light in weight
d.Suitable for high as well as extra high overhead voltage lines
Brief Description:
ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).
ACSR CONDUCTOR is available in a wide range of steel varying from as low as 6% to as high as 40 %.
The higher strength ACSR CONDUCTORS are used for river crossings, overhead ground wires,
installations involving extra long spans etc.. Against any given resistance of conductor,
ACSR CONDUCTORS may be manufactured for having a wide range of tensile strength as per requirement.
The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as
with lesser supports. Due to the greater diameter of ACSR CONDUCTORS a much higher corona limit can be obtained
causing big advantages on high as well as extra high voltage overhead lines.
Specifications:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
ACSR is composed by bare concentric-lay-stranded galvanized steel wire with aluminum wires surrounded by one or more layers of helically. Greased ACSR can
also be supplied.
ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001,
ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR CONDUTOR offers
optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing
ampacity. ACSR CONDUTORS are used extensively for overhead ground wires, river crossings etc.
These ACSR CONDUTORS are available with us in various types for meeting the exact requirements of the clients.
Standards:
ASTMB232,IEC61089,BS215,DIN,EN,GB/T 1179-83,Gost,AS Standards.
Features :
a.High tensile strength
b.Long life
c.Light in weight
d.Suitable for high as well as extra high overhead voltage lines
Construction:
Aluminum 1350-H19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B,or C galvanizing;
"aluminized" aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the core or infusion of the complete
cable with grease.
Package:In wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.Welcome your request for any quotations!