Simple Prefab Residential Houses
USD $120 - $280 /Set
Min.Order:1 Set
Vanjoin Hubei Building Industry Co., Ltd.
1. Wall: the interior and exterior wall panel are Vanjoin eps cement sandwich wall panel .It is
fast instruction ,light weight ,fire proof ,heat insulation ,water proof ,environment friendly ,
economic ,earthquake resistance.
2. Structure: the house frame structure can be steel structure or concrete structure .
3. Accessories: all the accessories will be enclosed ,such as the cement mortar, anti- cracking tape ,steel bar, window ,door ,roof ,ceiling ,tile ,painting and so on .
4. Main features of the prefab house
♦ Fast construction : three experienced workers can install 50m² per day by working 8 hours .The more workers the more sqm can be installed .
♦Durability: the steel structure is hot galvanized steel ,it is corrosion resistant and it can make sure the safety of the house .
♦ Heat insulation : the wall panel is very suitable for hot and cold area . Due to the polyphony granule in the panel ,the heat insulation effect is very good .
♦ Fire proof : under 1000 degree centigrade for 240 minutes ,there is no damage to the wall .It is tested by National Fire-proof Building Material Quality Supervision Testing Center .
♦ Environment friendly :raw materials do not include harmful substances ,it is green and safe .
♦Wind load and earthquake : it can resist the wind load 65m/s and 9 degree earthquake
Technology Index:
| Item | National Standards | Testing Indexes | ||||
60mm | 90mm | 120mm | 60mm | 90mm | 120mm | ||
1 | Anti-impact Capacity/times | ≥5 | ≥5 | ≥5 | ≥8 | ≥10 | ≥15 |
2 | Anti-bending damage load/times over deadweight | ≥1.5 | ≥1.5 | ≥1.5 | ≥3 | ≥4 | ≥5 |
3 | Compressive strength /Mpa | ≥3.5 | ≥3.5 | ≥3.5 | ≥5 | ≥5 | ≥5 |
4 | Softening coefficient | ≥0.80 | ≥0.80 | ≥0.80 | ≥1 | ≥1 | ≥1 |
5 | Surface density g/m2 | ≤70 | ≤90 | ≤110 | ≤55 | ≤70 | ≤85 |
6 | Moisture rate a/% | ≤12/10/8 | ≤10/9/7 | ||||
7 | Drying shrinkage value /mm/m | ≤0.6 | ≤0.6 | ≤0.6 | ≤0.45 | ≤.0.5 | ≤0.5 |
8 | Hanging Force/N | ≥1000 | ≥1000 | ≥1000 | ≥1200 | ≥1300 | ≥1500 |
9 | Sound insulation capacity in the air /dB | ≥30 | ≥35 | ≥40 | ≥35 | ≥40 | ≥45 |
10 | Fire proof limit /h | ≥1 | ≥1 | ≥1 | ≥2.5 | ≥3 | ≥4 |
11 | Heat transfer coefficient b/w/m2.k |
|
| ≤1.0 |
|
| ≤1.0 |
12 | Radioactivity Limit | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 |
13 | IRa (Inner radiation indexes) | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 |
14 | Ir (Outer radiation indexes) | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 |