grid inverter
electric parameter | 1.0KW HS1000TL-1 | 1.5KW HS1500TL-1 | 2.0KW HS2000TL-1 | 2.5KW HS2500TL-1 |
Input variables | ||||
Max Input Power | 1100 | 1600 | 2200 | 2700 |
maximum input voltage | 450 | 450 | 500 | 500 |
MTTP voltage range | 120-360 | 120-360 | 120-400 | 120-400 |
Shutdown dc voltage | 115 | |||
Maximum Input Current | 6 | 8 | 12 | 14 |
Number of input set of string | MC4*1 | |||
Maximum power tracking route | MPPT*1 | |||
Start the dc power | 10 | |||
Output variables(AC) | ||||
Max Input Power | 1000 | 1500 | 2000 | 2500 |
Max output A | 6 | 8 | 10 | 12 |
The output voltage range | Italy;CE1 0-21:ENGLAND:GB83/1 AUS:AS4777 CHINA QUALITY CERTIFICATE:COC | |||
Power range | Italy;CE1 0-21:ENGLAND:GB83/1 AUS:AS4777 CHINA QUALITY CERTIFICATE:COC | |||
Power factor | >0.99 | |||
Output current THD | <3% | |||
Ac output connections | AC | |||
Power loss | ||||
Night time loss | <1 | |||
Standby loss | 3 | |||
Current efficiency | ||||
(400Vdc) Maximum efficiency | 96% | 96.50% | 97.00% | 97.00% |
(400Vdc) Europen efficiency | 94% | 95.30% | 95.50% | 95.50% |
MPPT efficiency >99% | ||||
Security & protection | ||||
Over voltage protection | yes | |||
The insulation protection | yes | |||
Ground fault protection | yes | |||
An island protection | England:G83/1 AUS:AS4777 China quality certification center:CQC | |||
Safety standards | EN62109,EN61000-6-1,EN61000-6-3,EN61000-6-2,EN61000-6-4,EN61000-3-2,EN61000-3-3 | |||
Environmental parameters | ||||
Protection grade | IP65(outside) | |||
Working temperature range -20℃~+60℃ | ||||
(m) The altitude | below 2000 | |||
(db) Scope of noise | <25 | |||
General parameters | ||||
size(mm) | 394*300*130 | |||
weight(kg) | 11 | |||
heat insulating | The isolation type | |||
The cooling way | natural | |||
The shell material | aluminum | |||
installation | Metope installed | |||
Display panel | 2*LED, 128*64pi*LED | |||
Data transmission interface | RS485(3g,wifi,yitai) | |||
PC interface | RS485 | |||
quality assurance | 5year(choose 10-25 years warranty) |
electric parameter | 3.0KW HS3000TL-2 3.6KW HS3600TL-2 | 4.0KW HS4000TL-2 4.6KW HS4600TL-2 | 5.0KW HS5000TL-2 5.6KW HS5600TL-2 | 6.0KW HS6000TL-2 |
Input variables | ||||
(W) Max Input Power | 3200/3800 | 4200/4700 | 5200/5800 | 6200 |
(V) maximum input voltage | 550 | |||
(V) MTTP voltage range | 120-450 | |||
(V) Shutdown dc voltage | 115 | |||
(A) Maximum Input Current | 10+10 /12+12 | 13+13/14+14 | 15+15/15.5+15.5 | 16+16 |
Number of input set of string | MC4*2 | |||
Maximum power tracking route | MPPT*2 | |||
(W) Start the dc power | 10 | |||
Output variables(AC) | ||||
(W) Max Input Power | 3000/3600 | 4000/4600 | 5000/5600 | 5500/6000 |
(A) Max output A | 14/16 | 18/20 | 22/24 | 26 |
The output voltage range | 220 | |||
Power range | 50 | |||
Power factor | >0.99 | |||
Output current THD | <3% | |||
Ac output connections | AC | |||
Power loss | ||||
Night time loss | <1 | |||
Standby loss | 3 | |||
Current efficiency | ||||
(400Vdc) Maximum efficiency | 96.90%/96.96% | 97%/96.9% | 97.11%/97.31% | 97.47% |
(400Vdc) Europen efficiency | 96.18%/96.33% | 96.43%/95.96% | 96.24%/96.42% | 96.53% |
MPPT efficiency >99% | ||||
Security & protection | ||||
Over voltage protection | yes | |||
The insulation protection | yes | |||
Ground fault protection | yes | |||
An island protection | internal | |||
Safety standards | EN62109,EN61000-6-1,EN61000-6-3,EN61000-6-2,EN61000-6-4,EN61000-3-2,EN61000-3-3 | |||
Environmental parameters | ||||
Protection grade | IP65(outside) | |||
Working temperature range -20℃~+60℃ | ||||
(m) The altitude | below 1000 | |||
(db) Scope of noise | <25 | |||
General parameters | ||||
size(MM) | 378*300*131 | 528*300*131 | ||
weight(KG) | 18.5 | 19.5 | 19.5 | 19.5 |
heat insulating | The isolation type | |||
The cooling way | natural | |||
The shell material | aluminum | |||
installation | Metope installed | |||
Display panel | 2*LED, 128*64pi*LED | |||
Data transmission interface | RS485(3g,wifi,yitai) | |||
PC interface | RS485 | |||
quality assurance | 10year |
1. The hybrid wind soalr power system use inner foam protection outer Plywooden case .
2. Tower with Foam package only .
3. Solar panels controller invertor with inner carton box outer plywooden case.
4.Pakage size and weight please refer to our sales.
5.Shipping by sea with FCL LCL or by air .
Inverter are free 10 years warranty, All life long technical support and part cost supply.
(1) The warranty period is start from the date of shipment which show on the bill of loading or air waybill.
(2) Free maintenance services during the warranty period the cost involved be afford by the company, do not charge a fee to customers, free warranty if any damage outside the warranty period, the company will charge a fee for labor costs and materials.
(3) the warranty period, company's quality problems caused by the maintenance of the freight borne by the company, if not under warranty or man-made damage, the freight charges by the customer.