Radial View Ion Chromatography ( Made In China)
USD $1 - $35,000 /Piece
Min.Order:1 Piece
Shanghai Lilang Scientific Instrument Co., Ltd.
LT-IC300Ion Chromatography used a 5.7-inch LCD, advanced big screen technology and accurate temperature control design.And with standard double river road system can realize the anion and cation detection simultaneously, and can be selected many kinds of detector and automatic injection system ,which have a big advantage for the special samples and mass samples . It is suitable for the scientific research, the environmental monitoring, agricultural system water quality inspection and analysis.
Integration host, LCD screen,touch key operation, full screen display parameters, the parameters of automatic memory
with standard double river road system can realize the anion and cation detection simultaneously
Imported high pressure double piston pumps with a velocity range wide, bearing high voltage, bearing acid and alkali resistance, bearing 100% organic solvent characteristic
The unique infrared light electric sensing technology liquid-vapor separator, have the misstatement and omission etc. Function
All the peek material flow system adopts high voltage six valve, has the signal automatic data collection and continuous flow function
Automatic online degassing technology, can eliminate the flow of gas to dissolve in the analysis of interference
This technology can eliminate the dissolved gas flow phase of the interference analysis
The double inhibit mode:1)Continuously and automatically regeneration membrane inhibition;2)Ion chromatography film type CO2 inhibition
Column constant temperature system, built-in two sets of heating mode, can realize the rapid increase of chromatographic column box and accurate temperature control
High capacity, many kinds of ion chromatographic column can realize the conventional ions, disinfection by-products, organic acids and other components of the analysis
IT can realize conductivity detector, ultraviolet-visible light detector, column derivatives system, electrochemical detector system after the synchronous docking
Chromatographic working software with reverse control function, all Chinese/English shows, has the multi-channel data acquisition patent technology
Ion chromatographic pumps
Type: Imported high pressure double plunger tandem advection pump
Pump Pressure Range:42 MPa Flow range:0.001~9.999 mL/min
Pressure Display Accuracy:≤0.1 MPa Flow accuracy:RSD < 0.1 %
Flow repeatability:RSD≤0.1 %
Features: with a chemically inert non-metallic undamped pump head, connecting the PEEK line, suitable for PH0 ~ 14 eluent and inverted organic solvent; has high stability and repeatability.
Extended function: has the function of automatic cleaning double plunger pump head; overvoltage protection, working pressure exceeds or falls below the limit pressure automatic alarm and automatically stop the pump, self protection.
Thermostatic conductance detector
type: pentode type 316 stainless steel passivation electrode conductance pool
Test mode: Double conductivity detection Pool volume:≤0.9 μL
Resolution:≤0.0045 ns
Detection range:0~30000 μS/cm(10 files available)
Output voltage:-5000~5000 mv Baseline noise:≤0.6% FS
Baseline drift:≤±2.0% FS
Range of temperature:Room temperature +5 ℃ to 60 ℃
The precision of temperature control:±0.01 ℃
Temperature compensation:1.7 %/℃
Maximum operating pressure:5.0 MPa(750 psi)
Features:unique analog amplification technology, the use of advanced shielding technology and precise temperature control design, which eliminates polarization, the electric double layer and other negative effects, but also improve the stability and accuracy of conductance signals.
Flow system
Plastic flow path : the whole PEEK material
six-way valve: the United States Rheodyne high pressure valve six way valve, pressure 7000psi; a signal automatic collecting and flow function.
Features: high voltage, Naisuan Jian, a 100% organic solvent
Analysis ability
Anion analysis: F-,Cl-,Br-,I-,NO2-,PO43-,NO3-,SO42-,ClO2-,BrO3-,ClO3-and other anions and organic acid analysis
Cation analysis: Li+,Na+,NH4+,K+,Mg2+,Ca2+,Sr2+,Ba2+ cation; Betaine, choline chloride; organic amine analysis
Analysis of reproducibility: ≤1% (SO42-, Na+ meter ) linear range: ≥103
Minimum detectable concentration:≤5×10-4mg/L (Cl-meter ); ≤ 5×10-3mg/L(Na + meter )