EMHEATER frequency inverter vfd 3 phase 380V 75KW for pump & fan

EMHEATER frequency inverter vfd 3 phase 380V 75KW for pump & fan

USD $70 - $100,000 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
Shenzhen
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
EMHEATER
Model Number:
EM8-P3-075
Output Power:
1 - 200KW
Output Type:
Triple
Size:
590*380*312.5 mm

Shenzhen EMHEATER Technology Limited

Business Type: Manufacturer
Shenzhen Guangdong China
Main Products: frequency inverter ,soft starter ,servo motor and drive ,braking resistor ,filter and choke

Product Details

Specifications

1: Built-in RS485 communication port
2: All model are integrated IGBT

7EM8 Series V/F Control Inverter

Advantage Feature:

1: Wide Voltage Range: 320 ~ 480V

2: Input Frequency Range: 45 ~ 65Hz

3: Output Voltage Range: 0 ~ rated input voltage

4: Output Frequency Range: 0 ~ 500Hz

5: Overload Capacity: 60s with 150% of rated current, 2s with 180% of rated current

6: From 0.75 ~ 7.5KW Plastic house; 11 ~ 630KW is metal house

7: Control Mode: High Quality V/F Control

8: Speed Accuracy: V/F + 0.5% of maximum speed

9: 20 channels for frequency setting

10: Analog signal :0 ~ 10V,-10V ~ 10V,0 ~ 20mA.

11: Pulse setting input: 0~50Khz.

12: Built-in RS485 communication port

13: All model are integrated IGBT

14: The malfunction ratio is 0.8% within 18 months warranty.

EMHEATER frequency inverter vfd 3 phase 380V 75KW for pump & fan

Model Introduction:

EMHEATER frequency inverter vfd 3 phase 380V 75KW for pump & fan

Specification:

Items

Specification

Input

Rated voltage and frequency

Single phase 220V/Three phase380V + 15%, 47~ 63 Hz

Voltage allowable deviation range

200V~240V, 320V~460V

Output

Voltage

0~220V ,0~380V,0~460V,0~690V

Frequency

0Hz ~ 500Hz

Over-load capability

G3 Series:

  150% rated current for 1 minute

  180% rated current for 2 seconds

P3 Series:

  120% rated current for 1 minute

  150% rated current for 2 seconds

Control

character

Control mode

V/F Control

Freq. Setting resolution

Analog terminal input

0.1% of max output frequency

Digital setting

0.01Hz

Panel analog setting

0.4 % of max frequency

External pulse

0.1% of max frequency

Freq. accuracy

Analog Input

Within 0.2% of max. output frequency

Digital Input

Within 0.01% of setting output frequency

External pulse

Within 0.1% of max. output frequency

V/F Curve

(Voltage-Frequency character)

Base frequency can be set from 5~500Hz arbitrarily, and there are three kinds of curve: constant torque ,Dec torque 1 and Dec torque 2.

Torque Boost

Manual Setting: 0~20% of rated output, Auto-boost: Automatically boost torque according to output current.

Auto Energy-saving running

Adjust output voltage and slip compensation properly according to output current, which will make the motor working in highest efficiency.

Control

character

Acc./Dec. time setting

0.1~6000 seconds can be set continuously, and S type and line type can be selected.

Braking

Dynamic braking

Over 75% (External braking resistor)

DC braking

It is selected respectively at start and stop, and its frequency is 0~15Hz, the action voltage is 0~15%, and the action time is 0~20.0 second or act continuously.

Auto current-limiting function

Fast auto current-limiting function ensures not to occur the over-current during the accelerate process or under the impact load.

Overvoltage prevention

Ensure not over-voltage in Dec process.

Low noise running

Carrier freq. can be adjusted continuously form 1.5KHz to 15.0KHz, which can reduce the motor’s noise furthest.

Speed tracking restart

It can realize the smoothness restart and instantaneous stop then restart function.

Freq. setting

signal

Analog input

DC voltage 0~10V,-10V~10V, DC current 0~20mA ( Upper limit and Lower limit can be selected ).

Digital setting

By the running panel

Pulse input

0~10kHz (Upper limit and Lower limit can be selected)

Startup signal

FWD, REV, startup signal can be selected and self-keep (Three line control).

Timer and Counter

Embedded one timer and one counter ,which will help the system’s integration.

Multi-speed control function /

Wobble frequency

Seven steps programmable multi-speed control at most, every step’s running direction, running time can be set  respectively. In external terminal control, It reaches 15 steps, and there are 6 kind of running modes. Include wobble frequency.

Built-in

PID control

Common PID

Expediently compose the simple control system without accessional PID controller.

Special for water supply

(Need accessories)

Make it possible to construct the constant-pressure water-supply system of 4 pumps switch at most, which includes the following functions: pressure upper or Lower limit alarm, Sleep or wake, Timing water-supply etc. multi kind running mode.

Running function

Setting the upper and lower limit of frequency, frequency jump-running, reversal running limit, slip frequency compensation, auto constant-voltage running, RS485 communication frequency increment and decrement control, fault self-restore running, multi inverter coupled running.

Output signal

Running status

 (OC Output)

During the running of inverter, frequency arrival, frequency level detection, over-load alarm, and external fault stop-machine. Frequency upper-limit arrival, Frequency lower-limit arrival, under-voltage stop, zero-speed running, programmable multi-speed running state, Internal counter arrival, Internal timer arrival, Pressure lower-upper limit alarm.

Output signal

Indicating meter

Output Freq., output current, output voltage, motor speed, PID setting and feedback, external voltmeter, external cymometer.

Display

Running

panel display

Running status

Output Freq., output current, output voltage, motor rotate speed, setting frequency, PID setting, PID feedback, model temperature, accumulative running time, analog I/O, terminal Input status.

Alarm content

Last six fault records, output frequency, setting frequency, output current, output voltage, DC voltage, model temperature, terminal status, accumulative running time of Last fault trip.

Protective / Alarm function

Over-current, over-voltage, under voltage, electronic thermal protection, over-heat, short-circuit.

Operating

Environment

Temperature

-10ºC to +50ºC

Humidity

Below 90%RH(non-dewing)

Ambient environment

Indoors (no inflammable gasses or dust)

Altitude

Under 1000m

Structure

Protective class

IP20

Cooling method

Fans cooling

Mounting model

Wall mounting

Factory to shoot:

EMHEATER frequency inverter vfd 3 phase 380V 75KW for pump & fan

Application:

Product series EM8 - G1 / G3
Power range: 0.75 KW ~  630 KW
Areas of application: electronics, textile, light industry, building materials, food, machinery, printing and dyeing, petrochemical, paper, logistics transportation, Wire drawing machine, winding machine, blow molding, chemical fiber, tobacco, grinder, mixer, extruding machine, injection molding machine, chemical industry, etc.


Product series: EM8 - P3
Power range: 1.5 KW ~ 630 KW
Areas of application: water conservancy, electric power, municipal, chemical, mining, boiler fan, central air conditioning, sewage disposal blast Machine, iron and steel industry, mine water pump + fan exhaust system, cement industry, constant pressure water supply, etc

EMHEATER frequency inverter vfd 3 phase 380V 75KW for pump & fan

Contact Supplier

Ms. Sophia Cai Sales Manager Chat Now
Telephone
86-755-29985851
Mobile
13622341309
Fax
86-755-29970305
Address
xinan 4 road Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Supplies > Inverters & Converters
Categories
Hi~