Primary energy consumption top 10 air compressors
Primary energy consumption top 10 air compressors
Primary energy consumption top 10 air compressors
Primary energy consumption top 10 air compressors
Primary energy consumption top 10 air compressors

Primary energy consumption top 10 air compressors

USD $100 - $100 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Port:
Shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Condition:
New
Type:
Screw
Configuration:
Stationary
Power Source:
AC Power
Lubrication Style:
Lubricated
Mute:
Yes

ZiQi Compressor (Shanghai) Co., Ltd.

Business Type: Manufacturer,Trading Company
Shanghai China
Main Products: Air Compressor

Product Details

Primary energy consumption top 10 air compressors 

Product Description

 screw compressor for sale main configures as follows:

1. Main frame: ZiQi

2. Bearing:100% Sweden SKF (LIFE60000hours )

3. Solenoid valve: CEME Italy

4. Electro motor: ABB WOLONG

5. Thermostat valve : Austria Hoerbiger

6. Pressure sensor: Switzerland Huba imported with original

7. Container: shanghai shenjiang

8. Oil filter: Germany MANN company imported with original

9. Oil and gas separator: Germany MANN company imported with original

10. Lubricating Oil: Sweden Atlas screw air compressor oil imported with original

11. Suction valve: Sweden Atlas imported with original

12. Pressure valve: Hoerbiger Austria company

13. PLC: Schneider Electric France

14. Oil system configuration of the pipeline were chrome-plated brass

More than 80% of imported famous brand accessories!

 

 

The figure shows the comparison of several different start-up mode, we can see that the variable frequency driven compressor accpletely showly to star, is more stable than the soft-star, competely avoid the current peak, start variable frequency running when it comes to the rated pressure. then adapt to the operating environment of lack electricity at the largest extent.

 

ZIQI VFC intelligent serial screw compressor can precisely change the rotation speed of the main motor according to the change of the air consumption, based on stabilizing exhaust pressure, to output the air as user need, and only consume the necessary energy, then reach to energy saving purpose. in the whole cycle of compressor operation, energy savings will far exceed the compressor price

 

The figure shows the comparison of running condition between ordinary air compressor and inverter compressor. Frequency compressor work based on air consumption and air production balance, to avoid the machine loading and unloading frequently when the air consumption changing, it saves more than 35%energy compared to traditional compressor. steady pressure output, with the pressure loss control in 0.01Mpa-0.02Mpa, avoid the high load current loss which cased by the 0.05-0.2Mpa large pressure difference of tranditional compressor.

 

Technical parameter

 

 

Model

GA-37A

GA-45A

GA-55A/W

GA-75

A/W

GA-90

A/W

GA-110

A/W

GA-132

A/W

 

Air discharge/

Pressure discharge

 

 

 

 

m³/min/Mpa

 

 

6.82/0.7

7.42/0.7

10.83/0.7

14.11/0.7

16.1/0.7

21.0/0.7

25.2/0.7

6.24/0.8

7.11/0.8

9.20/0.8

13.02/0.8

15.0/0.8

19.8/0.8

24.0/0.8

5.74/1.0

6.22/1.0

8.61/1.0

12.04/1.0

13.8/1.0

17.9/1.0

21.0/1.0

4.93/1.2

5.65/1.2

7.71/1.2

10.06/1.2

12.3/1.2

15.3/1.2

18.3/1.2

No of compression stage

 

Single stage compression

Cooling model

 

A-Air cooling  W-Water cooling

Discharge temperature

ºC

≤The environment temperature  +15ºC (Air cooling)  ≤40ºC (Water cooling)

Noises Level

dB(A)

65±2

68±2

68±2

72±2

72±2

72±2

76±2

Transmission mode 

 

Belt Drive or Direct Drive (Optional)

Power supply

V/Ph/Hz

380/3/50 ,custom design is suitable

Motor power

kw

37

45

55

75

90

110

132

Starting model

 

                                 Y-Δ Start

External dimensions

L

mm

1715

1715

2045

2045

2650

2650

2400

W

mm

1090

1090

1230

1230

1640

1750

1450

H

mm

1635

1635

1820

1820

1850

1850

1800

Net Weight

Kg

1120

1200

1750

1820

2200

3000

3550

Air out pipe diameter

Inch

G1 1/2”

G1 1/2”

G2”

G2”

DN65

DN65

DN65

Volume Lubricant oil

L

22

22

  50

50

50

75

75

 

1.Host body ( air end )

2. Air end discharge terminal adopts SKF company TRB (tapered roller bearing)  

3. ABB Inverter

Primary energy consumption top 10 air compressors

 

 

4.The motor is Brazilian WEG brand

5.High quality Air filtre

 

picture

 

 

Primary energy consumption top 10 air compressorsPrimary energy consumption top 10 air compressorsPrimary energy consumption top 10 air compressorsPrimary energy consumption top 10 air compressors

 

Packaging & Shipping

 Primary energy consumption top 10 air compressors

 

Contact Supplier

Ms. Emily Du foreign sales Chat Now
Telephone
86-21-68148281
Mobile
15026767628
Fax
86-21-68148280
Address
28 Hangming Road.Pudong New Area Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Machinery > General Industrial Equipment > Air-Compressors
Categories
Hi~