KS-001 Ionizing Air Blower
Negotiable /Set
Min.Order:10 Sets
Shenzhen Kingsom Electronic Business Firm
Performance
1. it provides superior static charge decay rates over a targeted work surface area.
2. It provides optimum protection from the destructive effects of ESD.
3. it features an integrated heater for operator comfort.
Specification
Model | KS-001 |
Discharge Time | < 2 sec. at distance 300 mm. |
Air Volume Output | 45 CFM – 110 CFM (low – high) |
Effective Coverage | 400 x 1500 mm. ( area coverage) |
Power Requirements | 220V (0.2A) / 110V (0.4A) |
Dimension | 170mm (W) x 90mm (D) x 260mm (H) |
Weight | 3 Kg. |
Decay Test Results
Testing Conditions RH: 60% Temp 22 oC | |||
Testing Voltage 1 KV – 100V Operating Voltage 220V / 110V | |||
Warm Air Function | Yes | No | |
Distance | 300 mm | 300 mm | |
Decay Time | Positive | 1.4 Sec | 1.0 Sec |
Negative | 1.6 Sec | 1.1 Sec | |
Offset Voltage | Positive | 15 V | 8 V |
Negative | 15 V | 7 V |