Voltech PM1000+ Next Generation Power Analyzer

Voltech PM1000+ Next Generation Power Analyzer

Negotiable /Set

Min.Order:1 Set

Supply Ability:
10000 Set / Sets per Month
Port:
Hongkong

Quick Details View All >

Place of Origin:
United Kingdom
Brand Name:
Voltech
Model Number:
PM1000+
Measuring Current Range:
0~20Arms & +/-100A Peak Direct Input
Measuring Voltage Range:
0~600Vrms & +/-1500V Peak Direct Input
Accuracy Class:
0.1% basic accuracy

Besternasia Electronics Limited

Business Type: Trading Company
Shenzhen Guangdong China
Main Products: Switching Power Supply ,Power Module ,Rectifier Module ,Power Meter ,Power Supply System

Product Details

Specifications

1. Original PM1000+ x 5pcs Exstock
2. Low cost, high accuracy
3. Simple to use
4. FREE PC Software
5. Powerful features

  • High accuracy, low cost next generation power analyzer.
  • Direct connection – no CT errors.
  • Accurate up to Crest Factors of 20 – no compromise specification of distorted waveforms.
  • Rugged analog design - stands overloads up to 5kV.
  • Discrete Fourier Transform provides harmonics more accurately than FFT.
  • Voltech proprietary frequency detection avoids problems with zero-crossing detection.
  • Built with low power standby in mind - no special accessories or channels required.
  • High sample rate captures all the data and avoids aliasing problems.
  • Full color clear and versatile display with customizable graphing and measurement selection.
  • Great interfacing USB, IEEE, RS232.
  •  

    Specification
    VOLTAGERANGES
    Frequency Range
    Peak Continuous
    Peak < 1 second
    Input Impedance
    Display
    Crest Factor
    900, 215, 46, 10 Vpk
    10Hz to 1MHz
    1500 Vpk (over voltage)
    5000 Vpk (over voltage)
    1 MΩ
    4.5 Digits
    20 (Peak / RMS)
    RMS 45-65HzAccuracy0.05% of rdg +0.05% of
    range
    RMSAccuracy0/1% of rdg + 0.1% of range
    + 4mV + (0.02 * F)% of rdg
    DCAccuracy0.1% of rdg + 0.4% of range
    + 5mV
    VOLTAGE +/- PEAKAccuracy0.5% of rdg + 0.5% of range
    + (0.02 * F)% of rdg
    CURRENTRANGES
    Frequency range
    Peak Continuous
    Peak < 1 second
    Input resistance
    Crest Factor
    100, 25, 6.25, 1.6, 0.4, 0.1 Apk
    10Hz to 1MHz
    20Arms
    60Arms (over current)
    12.5mΩ
    20 (Peak/RMS)
    RMS 45-65HzAccuracy0.1% of rdg +0.1% of range
    RMSAccuracy0.1% of rdg + 0.1% of range
    + 1mA + (0.02 * F)% of rdg
    DCAccuracy0.1% of rdg + 0.4% of range
    + 1mA
    CURRENT +/- PEAKAccuracy0.5% of rdg + 0.5% of range +
    (0.02 * F)% of rdg
    WATTSRANGES
    Frequency range
    1W to 90kW
    10Hz to 1MHz
    RMS 45-65HzAccuracy[{(Verror/Vreading)
    +(Aerror/Areading)}*Wreading
    + 0.1% of W reading
     Accuracy0.2% rdg + 0.1% range + 4mW
    + ((0.05/PF) * F)% of rdg
    VARANGES
    Frequency range
    Accuracy
    1VA to 90kVA
    10Hz to 1MHz
    0.2% rdg + 0.1 % of range
    +4mVA + (0.05 * F)% of rdg
    VArRANGES
    Frequency range
    Accuracy
    1VAr to 90kVAr
    10Hz to 1MHz
    0.2% rdg + 0.1% range + 4mVAr
    +((0.05/1-PF) * F)% of rdg
    POWER FACTORPower Factor Range
    Accuracy
    -1.000 to +1.000
    +/-0.002 +/- ((0.001/PF) * F)
    FREQUENCYRANGE
    Accuracy
    DC and 10Hz to 1MHz
    0.1%
    VOLTAGE CREST FACTORRANGE
    Accuracy
    1.00 to 20.0
    %Vpk error + % Vrms error
    CURRENT CREST FACTORRANGE
    Accuracy
    1.00 to 20.0
    %Apk error + % Arms error
    PEAK INRUSH CURRENTRANGE
    Accuracy
    100Apk
    2% of range +/- 20mA
    HARMONIC ANAYLSISNumber of Voltage &
    Current Harmonics
    Maximum Harmonics
    Frequency
    Accuracy

    Frequency Range
    50

    450kHz
    0.2% of Reading + 0.1% of range
    +0.04% per kHz of Harmonics
    10Hz to 450kHz
    THD
    Total Harmonic Distortion
    Range & Accuracy

    Formula
    Range 0-999%
    Accuracy 0.4% + (0.1 * F)% of reading
    Series or difference
    STANDBY POWERTime Window
    Resolution
    1-300 sec
    1 second
    IMPEDANCERange
    Accuracy
    0.005Ω to 1MΩ
    0.2% of Reading +0.1% of range
    +5mΩ + ((0.05/PF) * F)% of reading
    RESISTANCERange
    Accuracy
    0.005Ω to 1MΩ
    0.2% of Reading + 0.1% of range
    +5mΩ + ((0.05/1-PF) * F)% of reading
    REACTANCERange
    Accuracy
    0.005Ω to 1MΩ
    0.2% of reading + 0.1% of range
    +5mΩ + ((0.05/PF) * F)% of reading
    EXTERNAL SHUNT
    Scaling
    Input Range+/- 1250 mVpk
    0.0001 to 100000
    MECHANICAL 1/2 rack size. Rack height 85mm
    W = 224mm. Height including feet 103mm
    D = 285mm. Weight 3.21Kg (7lbs.)

    Contact Supplier

    Ms. Lisa Li Sales Manager Chat Now
    Telephone
    86-755-33979011
    Mobile
    86-13928469002
    Fax
    86-755-86652135
    Address
    Room A, 5 Floor, Shuntian Building, Nanshan District, Shenzhen, China Shenzhen,Guangdong

    You May Like

    New Products

    Recommended Products

    View More View Less

    Find Similar Products By Category

    Measurement & Analysis Instruments > Electrical Instruments > Power Meters
    Categories
    Hi~