NES-100-48 48V meanwell power supply for led flood light
Negotiable /Piece
Min.Order:30 Pieces
Besternasia Electronics Limited
NES-100-48 48V meanwell power supply for led flood light
meanwell power supply led flood light Features:
48V meanwell power supply Safty Approval:
UL60950-1, ccc, CB Approved
NES-100-48 Specification:
Model | NES-100-48 | |
OUTPUT | DC VOLTAGE | 48V |
RATED CURRENT | 2.3A | |
CURRENT RANGE | 0-2.3A | |
RATED POWER | 110.4W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
VOLTAGE ADJ.RANGE | 45.6-52.8V | |
VOLTAGE TOLERANCE Note.3 | 1.00% | |
LINE REGULATION Note.4 | 0.50% | |
LOAD REGULATION Note.5 | 0.50% | |
SETUP, RISE TIME | 500ms,20ms/230VAC 500ms,20ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 30ms/230VAC 25ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 85-132VAC/176-264VAC selected by Swith 248-373VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 86% | |
AC CURRENT (Typ.) | 2A/115VAC 1.2A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 36A | |
LEAKAGE CURRENT | <2mA /240VAC | |
PROTECTION | OVERLOAD | 110-150% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 55.2-64.8V | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
ENVIRONMENT | WORKING TEMP. | -20-+60C( Refer to :Derating Curve") |
WORKING HUMIDITY | 20-90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40-+85C, 10-95% RH | |
TEMP. COEFFICIENT | 0.03%/ (0 ~ 50C ) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC | SAFETY STANDARDS Note.6 | UL60950-1,CB(IEC60950-1),CCC GB4943.1:2011 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25C/ 70% RH | |
EMC EMISSION | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-1, light industry level, criteria A | |
OTHERS | MTBF | 320.7K hrs min. MIL-HDBK-217F(25C) |
DIMENSION | 159*97*38mm (L*W*H) | |
PACKING | 0.52kg;30pcs/17.5kg/0.97CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature. | |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||
4. Line regulation is measured from low line to high line at rated load. | ||
5. Load regulation is meansured from 0% TO 100% rated load. | ||
6. For the request of GB4943.1, the power supply is only suitable for use in the altitude 2000m below and the non tropical climate condition. | ||
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests.please refer to "EMI testing of component power suppliers". |
Ordering Code:
NES-100-48 48V meanwell power supply for led flood light