RHD-601 Digital Car Antifreeze Freezing Point Refractometer
Negotiable /Piece
Min.Order:1 Piece
Shanghai Sunlight Electronic Technology Company Limited
RHD-601 Digital Car Antifreeze Freezing Point Refractometer
Application:
This model can be used for measuring the freezing point of either ethylene glycol or propylene based cooling systems and cleaner,it can be used for checking the strength of electrolyte solution batteries.
Features:
Operation temperature :0°C to 40°C (32°F to 104°F)
Temperature Measurement Range:0 to 40°C(32 to 104°F)
Power supply :1 battery (9V)
Alarm of low voltage
Automatic temperature compensation
Automatic shut off
Specification:
Product | Model | Parameter | Test Code | Measuring Range | Resolution | Accuracy | ATC |
Brix | RHD-101 | Brix | S01 | 0.0-50.0% | 0.10% | +/-0.2% | Yes |
Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | +/-0.0003nD | Yes | ||
RHD-102 | Brix | S01 | 0.0-90.0% | 0.10% | +/-0.2% | Yes | |
Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | +/-0.0003nD | Yes | ||
RHD-103 | Dextran | S01 | 0.0-10.6% | 0.10% | +/-0.2% | Yes | |
Fructose | S02 | 0.0-68.9% | 0.10% | +/-0.2% | Yes | ||
Glucose | S03 | 0.0-59.9% | 0.10% | +/-0.2% | Yes | ||
Lactose | S04 | 0.0-16.5% | 0.10% | +/-0.2% | Yes | ||
Maltose | S05 | 0.0-15.60% | 0.10% | +/-0.2% | Yes | ||
Refractive Index | S06 | 1.3330-1.4200nD | 0.0001nD | +/-0.0003nD | Yes | ||
Salinity | RHD-201 (Sodium Chloride NaCl) | salinity | S01 | 0.0-28.0% | 0.10% | +/-0.2% | Yes |
salinity | S02 | 0-280‰ | 1‰ | +/-2‰ | Yes | ||
specific gravity | S03 | 1.000-1.217 | 0.001 | +/-0.002 | Yes | ||
Refractive Index | S04 | 1.3330-1.3900nD | 0.0001nD | +/-0.0003nD | Yes | ||
RHD-202(Sea Water) | salinity | S01 | 0-100‰ | 1‰ | +/-2‰ | Yes | |
chlorinity | S02 | 0-57‰ | 1‰ | +/-2‰ | Yes | ||
specific gravity | S03 | 1.000-1.070 | 0.001 | +/-0.002 | Yes | ||
Refractive Index | S04 | 1.3330-1.3530nD | 0.0001nD | +/-0.0003nD | Yes | ||
Honey | RHD-301 | Brix | S01 | 0.0-90.0% | 0.10% | +/-0.2% | Yes |
Water | S02 | 38.0%-5.0% | 0.10% | +/-0.2% | Yes | ||
Be' | S03 | 33.0-48.0 | 0.1 | +/-0.2% | Yes | ||
Refractive Index | S04 | 1.3330-1.5177nD | 0.0001nD | +/-0.0003nD | Yes | ||
Grape Wine OE Beverage | RHD-401 | Brix% | S01 | 0.0-45.0% | 0.10% | +/-0.2% | Yes |
%VOL ap | S02 | 0.0-22.0% | 0.10% | +/-0.2% | Yes | ||
Oe | S03 | 3-150 | 1 | +/-2% | Yes | ||
KMW | S04 | 0.0-25.0 | 0.1 | +/-0.2 | Yes | ||
Beer Brix Wort S.G. | RHD402 | Brix | S01 | 0.0-50.0% | 0.1% | +/-0.2 | Yes |
Wort S.G. | S02 | 1.000-1.030 | 0.001S.G. | +/-0.002 | Yes | ||
Clinical Protein/Urine | RHD-501 | Urine S.G. | S01 | 1.000-1.050 | 0.001 | +/-0.002 | Yes |
Serum Protein. | S02 | 0-12 | 0.1 | +/-0.2 | Yes | ||
Refractive Index | S03 | 1.3330-1.3900nD | 0.0001nD | +/-0.0003nD | Yes | ||
Car | RHD-601 Antifreeze Freezing Point | Cleaner | S01 | 0~(-40)°C | 0.1°C | +/-0.5°C | Yes |
Ethylene Glycol | S02 | 0~(-50)°C | 0.1°C | +/-0.5°C | Yes | ||
Propylene Glycol | S03 | 0~(-50)°C | 0.1°C | +/-0.5°C | Yes | ||
Battery Fluid | S04 | 1.000-1.500sg | 0.001 | +/-0.005sg | Yes | ||
RHD-602 (Car Urea Concentration) | Urea (NH2)2C0 | S01 | 0-51.0% | 0.1% | +/-0.2% | Yes | |
Refractive Index | S02 | 1.3330-1.4056nD | 0.0001nD | +/-0.0003nD | Yes | ||
RHD-603 Coolant Freezing Point and Concentration | Ethylene Glycol (v/v) | S01 | 0-60% | 0.10% | +/-0.5% | Yes | |
Ethylene Glycol (°C) | S02 | 0~(-50)°C | 0.1°C | +/-0.5°C | Yes | ||
Propylene Glycol (v/v) | S03 | 0-70% | 0.10% | +/-0.5% | Yes | ||
Propylene Glycol (°C) | S04 | 0~(-60)°C | 0.1°C | +/-0.5°C | Yes | ||
RHD-604 Brake Fluid Boiling Point
| DOT3 | S01 | 121-260°C | 1°C | +/-10°C | Yes | |
DOT4 | S02 | 125-275°C | 1°C | +/-10°C | Yes | ||
Refractive Index | S03 | 1.3330-1.5177nD | 0.0001nD | +/-0.0003nD | Yes |