3-Axis ElectroSmog Meter , RF Meter, Electromagnetic Wave Field Strength Detector 50MHz to 3.5 GHz TES-92
Negotiable /Piece
Min.Order:1 Piece
Shanghai Sunlight Electronic Technology Company Limited
Digital Manometer Differential Pressure Gauge 5units Selectable RS232 AZ8252
Digital Manometer Differential Pressure Gauge 11units Selectable RS232 AZ8205
Digital Differential Pressure Gauge Manometer 11units Selectable RS232 AZ8215
Digital Differential Pressure Gauge Manometer 11units Selectable RS232 AZ8230
TES-92 ElectroSmog Meter
Applications:
High frequency (RF) electromagnetic wave field strength measurement.
Mobil phone base station antenna radiation power density measurement.
Wireless communication applications (CW , TDMA , GSM , DECT).
Wireless LAN (Wi-Fi) detection, installation.
Spy camera, wireless bug finder.
Cellular/Cordless phone radiation safety level.
Microwave oven leakage detection.
Personal living environment EMF safety.
RF power measurement for transmitters.
Features
50 MHz to 3.5 GHz frequency range.
For isotropic measurements of electromagnetic fields.
Non-directional (isotropic ) measurement with three-channel measurement probe.
High dynamic range due to three-channel digital results processing.
Configurable alarm threshold and memory function.
Easy to use
Specifications:
ELECTRICAL SPECIFICATIONS
Sensor type | Electric field (E) |
Frequency range | 50MHz to 3.5 GHz |
Directional characteristic | Isotropic, 3-dimensional |
Measurement range (CW signal>50MHz) | 20mV/m to 108.0V/m |
Absolute error(@1V/m and 50MHz) | ± 1.0dB |
Frequency response (taking into account typ. CAL factor) | ± 1.0dB (50MHz to 1.9 GHz) , ±2.4dB(1.9GHz to 35GHz) |
Isotropy deviation | Type. ±1.0dB in f>50 MHz |
Overload limit | 4.2W/m2 (40 V/m) |
Temperature response(0 to 50 °C) | ± 1.5dB |
Note | Unless otherwise stated, all specifications hold under the following assumptions: Sinusoidal signals; device in far-field of a source; probe head pointing toward source; ambient temperature +23 °C±3 °C;relative air humidity 25% to 75%. |
GENERAL SPECIFICATIONS
Measurement method | Digital , triaxial measurement |
Directional characteristic | Isotropic, triaxial |
Measurement range selection | One continuous range |
Display resolution | 0.1mV/m, 0.1 μA/m, 0.1 μW/m², 0.001 μW/cm² |
Setting time | Typically 1s ( 0 to 90% of meas. value) |
Display refresh rate | Typically 400mS |
Display type | LCD 4 digit |
Audible alarm | Buzzer |
Measurement units | mV/m , V/m , μA/m , mA/m , μW/m² , mW/m² , μW/cm² |
Measurement display value | Instantaneous measured value, maximum value or average value since power-on. |
Measurement alarm function | Adjustable threshold with ON/OFF |
Measurement calibration factor CAL | Adjustable |
Manual data memory and read storage | 99 sets ( only recall by meter ) |
Battery | 9V |
Battery life | >15 hours |
Accessory | 9V battery, carrying case & manual |