PROVA-6830A+6801 100A 3P4W True RMS Power and Harmonics Analyzer with USB Datalogger
Negotiable /Piece
Min.Order:1 Piece
Shanghai Sunlight Electronic Technology Company Limited
PROVA 6830A Power and Harmonics Analyzer
Feature
Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS Value (V 123 and L 123 )
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
Display of 35 Parameters in One Screen(3P4W)
Programmable CT (1 to 600) and PT (1 to 3000) Ratios
Display of Overlapped Voltage and Current Waveform
2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
Output of Waveform, Power Parameters and Harmonics at Command
Large Dot Matrix LCD Display with Backlight
Average Demand (AD in W, KW, MW)
Maximum Demand (MD in W, KW, MW) with Programmable Period
Harmonic Analysis to the 99th Order
Display of 50 Harmonics in One Screen with Waveform
Display of Waveform with Peak Values (1024 Samples/Period)
Analysis of Total Harmonic Distortion (%THD-F)
Graphic Phasor Diagram with 3 Phase System Parameters
Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
3 Phase Voltage Unbalance Ratio (VUR)
3 Phase Voltage Unbalance Factor (d0%, d2%)
Calculated Unbalance Current through Neutral Line (In)
Optical isolated USB Interface
Built-in Timer and Calendar for Data Logging
Conductor Size:
-Model 6801(100A) 30mm(approx),
210mm(L)*62mm(W)*36mm(H),200g(Weight)
-Model 6802(1000A) 55mm(approx),64*24mm(bus bar) 244mm(L)*97mm(W)*46mm(H),600g(Weight)
-Model 3007 (3000A)24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
-Model 3009 (1200A)18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
Specifications:
Please refer to users manual for more detailed and up-to-date description of specification
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)
Range | Resolution | Accuracy of Readings | ||
6800+6801 | 6800+6802 | 6800+3007 | ||
5.0 – 999.9W | 0.1W | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts |
1.000 – 9.999 KW | 0.001 KW | ±1% ± 8 dgts | ±1% ± 8 dgts | ±1% of VA Range ±8dgts |
10.00 – 99.99 KW | 0.01 KW | ±1% ± 8 dgts | ±1% ± 8 dgts | ±1% of VA Range ±8dgts |
100.0 – 999.9 KW | 0.1 KW | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts |
1000 – 9999 KW | 1 KW | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts |
0.000 – 9.999MW | 0.001MW | – | ±1% ± 8 dgts | ±1% of VA Range ±8dgts |
AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1)
| Range | Resolution | Accuracy of Readings |
6830+6801 (Overload Protection AC200A) | 0.050 – 9.999A | 0.001A | ±0.5% ± 5dgts |
10.00 – 60.00A | 0.01A | ±0.5% ± 5dgts | |
60.00 – 99.99A | 0.01A | ±1.0% ± 5dgts | |
6830+6802 (Overload Protection AC2000A) | 0.04 – 10.00A | 0.01A | – |
0.4A – 100.0A | 0.1A | ±0.5% ± 5dgts | |
4.0 – 1000.0A | 1A | ±0.5% ± 5dgts | |
6830+3007 (Overload Protection AC3500A) | 4 – 300A | 0.1A | ±1% of Range ±5dgts |
300.0 – 999.9A | 0.1A | ±1% of Range ±5dgts | |
1000 – 3000A | 1A | ±1% of Range ±5dgts |
AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4)
Range | Resolution | Accuracy of Readings | Range | Resolution | Accuracy of Readings |
4.0V – 500.0 (Phase to Neutral) | 0.1V | ± 0.5% ± 5dgts | 4.0V –600.0V (Phase to phase) | 0.1V | ± 0.5% ± 5dgts |
Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V)
Range | In Percentage | In Magnitude | ||
Resolution | Accuracy of readings | Resolution | Accuracy of readings | |
1 – 20 th | 0.1% | ±2% | 0.1 V | ±2% ±0.5V |
21 – 49 th | 4% of reading ±2.0% | 4% of reading ±0.5A | ||
50 – 99 th | 6% of reading ±2.0% | 6% of reading ±0.5A |
Harmonics of AC Current in % and in Magnitude
Model 6830+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range)
Range | In Percentage | In magnitude | ||
Resolution | Accuracy of reading | Resolution | Accuracy of reading | |
1 – 10 th | 0.1% | ±0.2 of reading ±1% | 0.1mA / 0.1A | ±0.2% of reading ±7dgts |
11 – 20 th | ±2% of reading ±1% | ±2% of reading ±7dgts | ||
2 1 – 50 th (A range) | ±5% of reading ±1% | ±5% of reading ±7dgts | ||
2 1 – 50 th (mA range) | ±10% of reading ±1% | ±10% of reading ±7dgts | ||
5 1 – 99 th | ±35% of reading ±1% | ±35% of reading ±7dgts |
Model 6830+6802(1000A);6830+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A)
Range | In Percentage | In Magnitude | ||
Resolution | Accuracy of reading | Resolution | Accuracy of reading | |
1 – 20 th | 0.1% | ±2% | 0.1A(6802) / 0.3A(3007) | ±2% of reading ±0.4A/0.6A |
21 – 49 th | 4% of reading ±2.0% | ±4% of reading ± 0.4A/0.6A | ||
50 – 99 th | 6% of reading ±2.0% | ±6% of reading ± 0.4A/0.6A |
Total Harmonic Distortion
Range | Resolution | Accuracy(6801) | Accuracy(6802) | Accuracy(3007) |
0.0 – 20% | 0.1% | ±1% | ±2% | ±2% |
20 – 100% | 0.1% | ±3% of reading ±5% | ±6% of reading ±1% | ±6% of Range ±1% |
100 – 999.9% | 0.1% | ±10% of reading ±10% | ±10% of reading ±1% | ±10% of Range ±1% |
Peak Value of Ac Voltage or AC Current ,VT=1
Range | Sampling Time | Accuracy of reading |
50Hz | 39 μS | ±5% ±30digits |
60Hz | 33 μS | ±5% ±30 digits |
Crest Factor (C.F.) of ACV or ACA ,VT=1
Range | Resolution | Accuracy of reading |
1.00 – 99.99 | 0.01 | ±5% ±30digits |
Frequency in AUTO mode
Range | Resolution | Accuracy of reading |
45 – 65Hz | 0.1Hz | 0.1Hz |
Power Factor (PF)
Range | Resolution | Accuracy of reading |
0.00 – 1.00 | 0.01 | ± 0.04 |
Phase Angle (Φ)
Range | Resolution | Accuracy of reading |
-180 . to 180 . | 0.1 . | ± 1 . |
Conductor Size (6801) | 30mm (approx) |
Conductor Size (6802) | 55mm(approx.), 64 X 24mm(Bus Bar) |
Battery Type | 1.5V SUM-3 x 8 |
Display | Dot Matrix LCD with backlight |
Power Consumption | 140mA (approx.) |
External DC Input | DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection) |
LCD update rate | 1 times / sec |
No. Of Samples/Period | 1024 |
Operating Humidity | < 85% relative |
Operating Temperature | -10°C to 50°C |
Storage Humidity | < 75% relative |
Storage Temperature | - 20°C to 60°C |
Weight(6830) | 1160g |
Weight(6801) | 200g |
Weight(6802) | 600g |
Weight(3009) | 390g |
Weight(3007) | 410g |
Dimension(6830) | 257mm(L) x 155mm(W) x 57mm(H), 10.1"(L) x 6.1" (W) x 2.3" (H) |
Dimension(6801) | 210mm(L) x 62mm(W) x 36mm(H), 8.3 " (L) x 2.5" (W) x 1.4" (H) |
Dimension(6802) | 244mm(L) x 97mm(W) x 46mm(H), 9.6 " (L) x 3.8" (W) x 1.8" (H) |
Dimension(3009) | 130mm(L) x 80mm(W) x 43mm(H), 5.1 " (L) x 3.1" (W) x 1.7" (H) |
Dimension(3007) | 130mm(L) x 80mm(W) x 43mm(H), 5.1 " (L) x 3.1" (W) x 1.7" (H) |
Accessories | Test leads x 4,alligator clips x 4,Carrying bag x 1,Users manual x 1,Batteries 1.5V x 8 |