PROVA 6830A Power and Harmonics Analyzer

 

Feature
Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS Value (V 123 and L 123 )
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
Display of 35 Parameters in One Screen(3P4W)
Programmable CT (1 to 600) and PT (1 to 3000) Ratios
Display of Overlapped Voltage and Current Waveform
2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
Output of Waveform, Power Parameters and Harmonics at Command
Large Dot Matrix LCD Display with Backlight
Average Demand (AD in W, KW, MW)
Maximum Demand (MD in W, KW, MW) with Programmable Period
Harmonic Analysis to the 99th Order
Display of 50 Harmonics in One Screen with Waveform
Display of Waveform with Peak Values (1024 Samples/Period)
Analysis of Total Harmonic Distortion (%THD-F)
Graphic Phasor Diagram with 3 Phase System Parameters
Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
3 Phase Voltage Unbalance Ratio (VUR)
3 Phase Voltage Unbalance Factor (d0%, d2%)
Calculated Unbalance Current through Neutral Line (In)
Optical isolated USB Interface
Built-in Timer and Calendar for Data Logging
Conductor Size:
-Model 6801(100A) 30mm(approx),
210mm(L)*62mm(W)*36mm(H),200g(Weight)
-Model 6802(1000A) 55mm(approx),64*24mm(bus bar) 244mm(L)*97mm(W)*46mm(H),600g(Weight)
-Model 3007 (3000A)24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
-Model 3009 (1200A)18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)

 

Specifications:

Please refer to users manual for more detailed and up-to-date description of specification

AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)

Range

Resolution

Accuracy of Readings

6800+6801

6800+6802

6800+3007

5.0 – 999.9W

0.1W

±1% ± 8dgts

±1% ± 8dgts

±1% of VA Range ±8dgts

1.000 – 9.999 KW

0.001 KW

±1% ± 8 dgts

±1% ± 8 dgts

±1% of VA Range ±8dgts

10.00 – 99.99 KW

0.01 KW

±1% ± 8 dgts

±1% ± 8 dgts

±1% of VA Range ±8dgts

100.0 – 999.9 KW

0.1 KW

±1% ± 8dgts

±1% ± 8dgts

±1% of VA Range ±8dgts

1000 – 9999 KW

1 KW

±1% ± 8dgts

±1% ± 8dgts

±1% of VA Range ±8dgts

0.000 – 9.999MW

0.001MW

±1% ± 8 dgts

±1% of VA Range ±8dgts

 

AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1)

 

Range

Resolution

Accuracy of Readings

6830+6801

(Overload Protection AC200A)

0.050 – 9.999A

0.001A

±0.5% ± 5dgts

10.00 – 60.00A

0.01A

±0.5% ± 5dgts

60.00 – 99.99A

0.01A

±1.0% ± 5dgts

6830+6802

(Overload Protection AC2000A)

0.04 – 10.00A

0.01A

0.4A – 100.0A

0.1A

±0.5% ± 5dgts

4.0 – 1000.0A

1A

±0.5% ± 5dgts

6830+3007

(Overload Protection AC3500A)

4 – 300A

0.1A

±1% of Range ±5dgts

300.0 – 999.9A

0.1A

±1% of Range ±5dgts

1000 – 3000A

1A

±1% of Range ±5dgts

 

AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4)

Range

Resolution

Accuracy of Readings

Range

Resolution

Accuracy of Readings

4.0V – 500.0 (Phase to Neutral)

0.1V

± 0.5% ± 5dgts

4.0V –600.0V (Phase to phase)

0.1V

± 0.5% ± 5dgts

 

Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V)

Range

In Percentage

In Magnitude

Resolution

Accuracy of readings

Resolution

Accuracy of readings

1 – 20 th

0.1%

±2%

0.1 V

±2% ±0.5V

21 – 49 th

4% of reading ±2.0%

4% of reading ±0.5A

50 – 99 th

6% of reading ±2.0%

6% of reading ±0.5A

 

Harmonics of AC Current in % and in Magnitude
Model 6830+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range)

Range

In Percentage

In magnitude

Resolution

Accuracy of reading

Resolution

Accuracy of reading

1 – 10 th

0.1%

±0.2 of reading ±1%

0.1mA / 0.1A

±0.2% of reading ±7dgts

11 – 20 th

±2% of reading ±1%

±2% of reading ±7dgts

2 1 – 50 th (A range)

±5% of reading ±1%

±5% of reading ±7dgts

2 1 – 50 th (mA range)

±10% of reading ±1%

±10% of reading ±7dgts

5 1 – 99 th

±35% of reading ±1%

±35% of reading ±7dgts

 

Model 6830+6802(1000A);6830+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A)

Range

In Percentage

In Magnitude

Resolution

Accuracy of reading

Resolution

Accuracy of reading

1 – 20 th

0.1%

±2%

0.1A(6802) / 0.3A(3007)

±2% of reading ±0.4A/0.6A

21 – 49 th

4% of reading ±2.0%

±4% of reading ± 0.4A/0.6A

50 – 99 th

6% of reading ±2.0%

±6% of reading ± 0.4A/0.6A

 

Total Harmonic Distortion

Range

Resolution

Accuracy(6801)

Accuracy(6802)

Accuracy(3007)

0.0 – 20%

0.1%

±1%

±2%

±2%

20 – 100%

0.1%

±3% of reading ±5%

±6% of reading ±1%

±6% of Range ±1%

100 – 999.9%

0.1%

±10% of reading ±10%

±10% of reading ±1%

±10% of Range ±1%

 

Peak Value of Ac Voltage or AC Current ,VT=1

Range

Sampling Time

Accuracy of reading

50Hz

39 μS

±5% ±30digits

60Hz

33 μS

±5% ±30 digits

 

Crest Factor (C.F.) of ACV or ACA ,VT=1

Range

Resolution

Accuracy of reading

1.00 – 99.99

0.01

±5% ±30digits

 

Frequency in AUTO mode

Range

Resolution

Accuracy of reading

45 – 65Hz

0.1Hz

0.1Hz

 

Power Factor (PF)

Range

Resolution

Accuracy of reading

0.00 – 1.00

0.01

± 0.04

 

Phase Angle (Φ)

Range

Resolution

Accuracy of reading

-180 . to 180 .

0.1 .

± 1 .

 

Conductor Size (6801)

30mm (approx)

Conductor Size (6802)

55mm(approx.), 64 X 24mm(Bus Bar)

Battery Type

1.5V SUM-3 x 8

Display

Dot Matrix LCD with backlight

Power Consumption

140mA (approx.)

External DC Input

DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection)

LCD update rate

1 times / sec

No. Of Samples/Period

1024

Operating Humidity

< 85% relative

Operating Temperature

-10°C  to 50°C

Storage Humidity

< 75% relative

Storage Temperature

- 20°C  to 60°C

Weight(6830)

1160g

Weight(6801)

200g

Weight(6802)

600g

Weight(3009)

390g

Weight(3007)

410g

Dimension(6830)

257mm(L) x 155mm(W) x 57mm(H), 10.1"(L) x 6.1" (W) x 2.3" (H)

Dimension(6801)

210mm(L) x 62mm(W) x 36mm(H), 8.3 " (L) x 2.5" (W) x 1.4" (H)

Dimension(6802)

244mm(L) x 97mm(W) x 46mm(H), 9.6 " (L) x 3.8" (W) x 1.8" (H)

Dimension(3009)

130mm(L) x 80mm(W) x 43mm(H), 5.1 " (L) x 3.1" (W) x 1.7" (H)

Dimension(3007)

130mm(L) x 80mm(W) x 43mm(H), 5.1 " (L) x 3.1" (W) x 1.7" (H)

Accessories

Test leads x 4,alligator clips x 4,Carrying bag x 1,Users manual x 1,Batteries 1.5V x 8

 PROVA-6830A+6801 100A 3P4W True RMS Power and Harmonics Analyzer with USB Datalogger

Contact Supplier

Mr. David Chen Sales Manager Chat Now
Telephone
86-21-51828967
Mobile
86 18621717855
Fax
86-21-51828367
Address
R.823 NO.1909 Caoan Road Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
Categories
Hi~