Specifications
Ultrasonic Thickness Gauge,paint thickness meter, coating thickness tester, thickness tester, UM-2
Ultrasonic Thickness Gauge UM-2
UM-2 Ultrasonic Thickness Gauge measures the thickness of an object by precisely calculating the time of the probe sending ultrasonic pulse with the help of couplant to the object and passing through the object until the probe receiving the reflection from the boundary. The operating principle is P-E (pause-echo). The measuring range is 0.031’’-11.811’’.
Standard package:
UM-2 thickness gauge
Standard probe (PT-08)
Carrying case
Two 1.5V AA alkaline batteries
Couplant
Operating manual
Certification of quality
Packaging list
Operating principle:
Ultrasonic pulse/echo method with dual-element probes
Probe zero adjustment:
Selectable: 1-point calibration: normal measurement
2-point calibration: curve surface measurement or other special application with a high precision
V-path correction:
Automatic
Measuring range:
0.8mm to 300mm; 0.031in to 11.81in
Depending on probe, material and surface condition
Digital resolution:
H less than 4in : 0.001in /0.01in or 0.01mm/0.1mm
H more than or equal to 4in : 0.01in or 0.1mm
Units:
Selectable: inch or mm
Display:
128×64 dot-matrix LCD screen (1.65in×2.24in; 42mm×57mm)
EL backlight and switchable contract ratio
Digit height: 0.54in or 13.75mm
Measurement update rate:
4 Hz in standard measurement mode
25 Hz in MIN capture mode
Material velocity range:
1000 to 9999 m/s; 0.039 to 0.394 inch/µs
Power:
Two 1.5V AA alkaline batteries
Warning with low battery voltage
Operating time:
Up to 200 hours (without backlight) with alkaline batteries, depending on operating mode
Auto shut-off:
After 5 minutes of non-use
Operating temperature:
-10C to +50C; +14F to +122F
Specification to -20C/-4F on request
Size:
5.86in×2.87in×1.25in; 149mm×73mm×32mm (H×W×D)
Weight:
200g / 0.44lb (including batteries)
Dta logger capacity:
Up to 500 readings can be divided into a maximum of 5 files (user-selectable)
Optional accessories:
Attachable rubber case
Numerous special probes on request
Couplants and high-temperature couplant
4-step/6-step block for calibration
Data transmission cable
Application software
perating language:
English and Chinese
Measuring error:
Up to 1in: +/-0.002in or +/-0.05mm
Above 1in: +/-0.5%H
H is the height of the testing object
Repeatability:
+/-0.001in or +/-0.025mm
Interfaces:
Serial RS 232C port in combination with a communicative cable;
Data transfer parameters: 8 bits, 1 stop bit, 9600 baud, no parity.