MS7281 Process Calibrator,True RMS Auto Range Process MeterK-type AC Current& DC AC Voltage with Backlight
USD $220 - $280 /Piece
Min.Order:1 Piece
Shenzhen Graigar Technology Co., Ltd.
NEW NDT650 ultrasonic flaw detection of a variety of defects within the workpiece
NEW NDT-510A Paint coating thickness gauge (0-6000 - um) in a wide range
NEW NDT520 coating thickness gauge Film thickness gauge Metal thickness gauge
NEW NDT320 high-precision thickness gauge Ultrasonic thickness meter The steel plate thickness gauge
MS7281 Process Calibrator,True RMS Auto Range Process MeterK-type AC Current& DC AC Voltage with Backlight
MS7281 is a portable and specialized process verification instrument, which serves as a digital verification meter that has both digital multimeter and signal source function, and can measure and output signal simultaneously. Its large liquid crystal digital display can show the measured signal value and output signal value, and it is equipped with backlight which makes the user easier to read the value. It uses large-capacity rechargeable battery pack and is featured with low voltage indication. Charging and operating for this instrument can be conducted simultaneously (with a charger). Signal output and measurement function of the instrument is mainly designed for on-site verification and service of an instrument in industrial automation field. This instrument is also featured with multimeter function, which makes it an ideal option for field metermen, computer distributed control system maintainer, meter mounter, and can be used as a multimeter by the meterman
Current Measurement | Range: | 0-400mA DC | 0-400mA AC | ||||
Resolution: | 0.1 mA | 0.1 mA | |||||
Accuracy: | 0.1% Rdg + 5LSD | 1% Rdg + 5LSD | |||||
Voltage measurement | Range: | 1000VDC | 0-700 VAC | ||||
Resolution: | 1.0 V | 1.0 V | |||||
Accuracy: | 0.1% Rdg+5LSD | 0.8% Rdg + 5LSD | |||||
Frequency measurement | 20Hz to 50 kHz, 0.05% + 5LSD | ||||||
Resistance measurement | to 4 MΩ , 0.3% Rdg + 5 LSD; 4 MΩ to 40 MΩ 0.5% + 50 LSD | ||||||
Capacitance measurement | to 100 F , 2.0 % Rdg + 10LSD | ||||||
Temperature measurement | K-type Thermocouple (optional). | ||||||
Diode measurement | 2.4 V shows diode voltage drop | ||||||
Current Sourcing | Range: | 0-22 mA | |||||
Accuracy | 0.1% Rdg + 5LSD | ||||||
Drive Capability: | 1000 Ω @ 20 mA | ||||||
DC voltage signal output | Range: | 10VDC | 100mVDC | ||||
Resolution: | 10mV | 0.1mV | |||||
Accuracy: | 0.1% Rdg+5LSD | 0.1% Rdg+5LSD | |||||
Frequency signal output | Range: | 100Hz | 1KHz | 10KHz | |||
Resolution: | 0.01Hz | 0.1Hz | 1Hz | ||||
Accuracy: | 0.1Hz | 0.5Hz | 5Hz | ||||
24DC voltageSourcing | Accuracy: 2% ; Drive Capability: 30 mA | ||||||
|