NEW Deviser NA7100 1.3GHz Vector Network Analyzer
USD $1 - $2 /Piece
Min.Order:1 Piece
Shenzhen Graigar Technology Co., Ltd.
Deviser NA7100 1.3GHz Vector Network Analyzer
Overview
NA7100 is mainly applied for Communication, Satellite, Wireless TV & Broadcast and CATV industries.
Application
NA7100 is the best combination of high speed, accuracy, productive and low cost. It helps reduce the testing time, increase output,and lower the overall cost of components. The analyzer is qualified in testing typical RF components such as: Filter, Amplifier, Antennas, Cables,Taps, and Splitters.
Main Testing Functions
NA7100 is the best combination of high speed, accuracy, productive and low cost. It helps reduce the testing time, increase output, and lower the overall cost of components. The analyzer is qualified in testing typical RF components such as: Filter, Amplifier, Antennas, Cables, Taps, and Splitters.
Communication: Antenna, Amplifying Module, Coaxial Cable, Connector and so on
Satellite TV: Amplifiers, Spliters and so on
Wireless Broadcasting & TV: Antenna, Transmitter
CATV: Amplifiers, Spliters and so on
Other industries: researching and manufacture of crystal, surface acoustic and cable.
Model
NA7100A 50 Ω
NA7100B 75 Ω
Key Features
Specifications
NA7300 NA7100 | ||
Source | ||
Frequency Range | 300 kHz ~ 3 GHz | 300 kHz ~ 1.3 GHz |
Frequency stability | ≤±5 ppm | ≤±5 ppm |
Frequency Resolution | 1 Hz | 1 Hz |
Phase Noise | ≤ -65 dBc/Hz @10 kHz | ≤-67 dBc/Hz (10 kHz Offset) |
Output Level Range | -48 dBm ~ +10 dBm | -50 dBm ~ +10 dBm |
Level Accuracy | ≤±1.5 dB (-45 dBm ~ +5 dBm) | ≤±1.5 dB (25 °C+5°C) |
Harmonic Rejection | ≥-30 dBc (>1 MHz) ≤-25 dBc (≤1 MHz) | ≥-30 dBc(>1 MHz) ≤-25 dBc(≤1 MHz) |
Directivity | ≥50 dB (After Vector calibration) | ≥50 dB (After Vector calibration) |
VSWR | ≤1.3 | ≤1.3 |
Receiver | ||
Resolution Bandwidth | 100 Hz ~ 15 kHz | 100 Hz ~ 15 kHz |
Dynamic Range | ≥100 dB (RBW=1 kHz) | ≥100 dB (RBW=1 kHz) |
Level Accuracy | ≤±1.5 dB | ≤±1.5 dB |
Measurement Resolution | 0.01 dB | 0.01 dB |
Maximum Input Level | + 10 dBm | + 10 dBm |
VSWR | ≤1.2 | ≤1.2 |
Phase | ||
Phase Resolution | 0.01 ° | 0.01 |
Phase Stability | 0.5 ° (RBW=1 kHz) 1 ° (RBW=3 kHz) | 0.5 ° (RBW=1 kHz) 1 ° (RBW=3 kHz) |
Display | ||
Sweep Time | 150 ms/field ~ 20 s/field(201points) | 150 ms/field ~ 5 s/field (201points) |
Display | 7.5” Color TFT LCD | 7.5” Color TFT LCD |
Measurement | ||
Measurement Channels | 2 channels,4 tracks | |
Measurement Format | A,B,R,A/R,B/R,A/B | |
Measurement Parameters | Logarithm amplitude, Linearity amplitude, Phase, Group delay Real part, Imaginary part. VSWR, Smith chart, Pole chart | |
Interface | ||
Front Panel | Type-N Input and Output port,USB1.1 port | |
Rear Panel | RS-232, Parallel interface, Standard VGA output andStandard keyboard interface | |
Others | ||
Power Supply | AC 90 V ~ 250 V / 50 Hz, P≤113 W | |
Weight | 15 kg | |
Working Environment: | Temperature: -10 °C ~ 40 °C,Humidity: ≤75% | |
Store Environment: | -10 °C ~ 50 °C | |
Inside Storage | 1 G Byte | |
Dimension | 400 mm × 220 mm × 470 mm |