The force gauge has advantages of high precision, easy operation and carry. What's more, it has
kinds of testing modes, convenience for conner and it can store and input data to computer for
statistical analysis as well as constitutes testers with different functions, combinating with test-beds and clamp. Users can input local acceleration of gravity value to make test more precise.
Functional characteristics:
1. High precision and high resolution.
2. Five testing modes and three display methods for selection--enhancetesting efficiency to the maximum extent
3. N (Newton), kg (Kilogram) and lb (Pound) three measuring units for selection and conversion.
4. Setting function of gravity acceleration---User can input at your option the accurate value of gravity acceleration at the using place so as to
make the testing and unit conversion be more accurate.
5. Function of peak value maintaining. Maintain the display of peak value until manual zero clearing.
6.Automatic peak function. Maintain the display of peak value for 2 seconds and then release automatically.
7.Max and min and comparison value can be set for statistic analysis. The buzzer will alarm if
exceeding comparison value.
8. Data storage function. 896 testing values can be stored.
9.Data output function. The data can be input into computer through data line for various analyses.
10. Environmental protection. The device will automatically stop if no operation within 10 minutes.
11. High quality chargeable power supply. The charging voltage is avai-lable from 100V to 240V, which can accommodate most areas in domestic and at abroad. It has
also protection functions for short circuit, leakage and overload.
12.2 sets mounting dimensions, it is applied for most testing platforms domestically and easy for
users to install it to platform.
13. Special testing function of make-break ability of switch contact to make the make
break testing be more accurate.
14. 6 digits large screen display.
15.Synchronous measuring softwarecan connect computer measuring, the computer display
measuring graph and the detailed testing records,and can preserve, print ,make analysis,input
speed, area, displacement, pressure. ( chosen functiondetails see CD data )
16. Contact control signal outputsetting comparative value,when the Measuring value is over
comparative value, output signal control circuit Breaker's make-and break, thus realize the function of stop electromotor, And control automatically; it is also can be
used for realize other control Functions, for example input signal to plc to realize automatization.
Also it can set signal output mode, for example output signal at some Measuring range. There is
a jack on the side of apparatus can put one Side of connection line to secondary jack, and the
other side in the jack On the testing machine which is produced by our company, thus it can
realize function of stop electromotor automatically when the measuringValue is over comparative
value. The comparative value can set by himself.
17. Negative phototropism functionuse key-press or apparatus is stressed,the negative photo tropism would light automatically, it will close
negative phototropism if 10s non-operation; it also can press "setting" key 6 times ,enter 'light" condition, choose "NO" to close
negative phototropism, chose "YES" to start the function automatically.
18. LCD overturn display press "print" key can make the value reverse 180°,convenience for looking
the measuring value from different angle.
19. Reset quickly when system halted accidentally install reset key on the side , then press the key
swith forcely can make power off.
Force gauge mode specification sheet
Model specification sheet of force gauge with inner sensor
Model specification | HF-2 | HF-5 | HF-10 | HF-20 | HF-50 | HF-100 | HF-200 | HF-500 | HF-1000 |
Peak load value | N | 2 | 5 | 10 | 20 | 50 | 100 | 200 | 500 | 1000 |
kg | 2 | 0.5 | 1 | 2 | 5 | 10 | 20 | 50 | 100 |
lbs | 0.44 | 1.1 | 2.2 | 4.4 | 11 | 22 | 44 | 110 | 220 |
load division value | N | 0.001 | 0.001 | 0.01 | 0.01 | 0.01 | 0.1 | 0.1 | 0.1 | 1 |
kg | 0.0001 | 0.0001 | 0.001 | 0.001 | 0.001 | 0.01 | 0.01 | 0.01 | 0.1 |
lbs | 0.0001 | 0.0001 | 0.001 | 0.001 | 0.001 | 0.01 | 0.01 | 0.01 | 0.1 |
Indication error | 0.50% |
Unit | N / kg / lbs |
Data interface | Rs232 nine-hole socket |
Power | rechargeable batteries, charger(charging voltage 100V-240V) |
Sensor structure | S-tye sensor with high precision (inner sensor) |
Ambient temperature | 5° C~35° C |
Tansport temperature | -10° C~60° C |
Relative humidity | 15%~80%RH |
Working conditions | No hypocenter and corrosive medium |
Gross weight | ~2000g |
Size | 273 x 182 x70 mm |
Model specification sheet of force gauge with external sensor
Model specification | HF2000 | HF5000 | HF10K | HF20K | HF50K | HF100K | HF200K | HF500K | HF1000K |
Peak load value | 2000N | 5000N | 10KN | 20KN | 50KN | 100KN | 200KN | 500KN | 1000KN |
load division value | 1N | 1N | 0.01KN | 0.01KN | 0.01KN | 0.1KN | 0.1KN | 0.1KN | 1KN |
0.1kg | 0.1kg | 0.001Mg | 0.001Mg | 0.001Mg | 0.01Mg | 0.01Mg | 0.01Mg | 0.1Mg |
0.1lbs | 0.1lbs | 0.001Klbs | 0.001Klbs | 0.001Klbs | 0.01Klbs | 0.01Klbs | 0.01Klbs | 0.1Klbs |
Indication error | ±0.5% | ±1% |
Unit | N / (KN), kg / (Mg or t), lbs (Klbs) |
Data interface | Rs232 nine-hole socket |
Power | rechargeable batteries, charger(charging voltage 100V-240V) |
Sensor structure | S-tye or column sensor with high precision (extenal sensor) |
Ambient temperature | 5° C~35° C |
Tansport temperature | -10° C~60° C |
Relative humidity | 15%~80%RH |
Working conditions | No hypocenter and corrosive medium |
Gross weight | 6 kg | 9 kg | 24 kg | 36 kg |
Size | 280 x 200 x 170 mm | 310 x 260 x 190 mm |
Model specification | HF3000K |
Peak load value | 3000KN |
load division value | 1KN |
0.1Mg |
0.1Klbs |
Indication error | ±1% |
Unit | N / (KN), kg / (Mg or t), lbs (Klbs) |
Data interface | Rs232 nine-hole socket |
Power | rechargeable batteries, charger(charging voltage 100V-240V) |
Sensor structure | S-tye or column sensor with high precision (extenal sensor) |
Ambient temperature | 5° C~35° C |
Tansport temperature | -10° C~60° C |
Relative humidity | 15%~80%RH |
Working conditions | No hypocenter and corrosive medium |
Gross weight | 36 kg |
Size | 310 x 260 x 190 mm |