DSO8072E Oscilloscope High Bandwidth 70MHz-200MHz Oscilloscope 1GS/s Sample Rate,2M Memory Depth
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Graigar Technology Co., Ltd.
DSO8072E Oscilloscope High Bandwidth 70MHz-200MHz Oscilloscope 1GS/s Sample Rate,2M Memory Depth
Model | DSO8072E | DSO8102E | DSO8152E | DSO8202E |
Acquisition | ||||
Sample Modes | Real-Time Sample | |||
Acquisition Modes | ||||
Normal | Normal data only | |||
Peak Detect | High-frequency and randon glith capture | |||
Average | Wavefom Average, selectable 4,8,16,32,64,128 | |||
Inputs | ||||
Inputs Coupling | AC, DC, GND | |||
Inputs Impendance | 1MΩ±2% 20pF±3pF | |||
Probe Attenuation | 1X, 10X | |||
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | |||
Maximum Input Voltage | CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×) | |||
Horizontal System | ||||
Sample Rate Range | 1GS/s | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | 2M | |||
SEC/DIV Range | 4ns/div~2000s/div, in a 2, 4, 8 sequence | 2ns/div~2000s/div, in a 2, 4, 8 sequence | ||
Sample Rate and Delay Time Accuracy | ±50ppm over any ≥1ms time interval | |||
Scanning Speed Range | 4ns/div to 8ns/div; (-8div x s/div) to 40ms; 20ns/div to 80μs/div;(-8div×s/div) to 40ms; 200μs/div to 40s/div;(-8div×s/div) to 400s; | 2ns/div to10ns/div;(-4div×s/div) to 20ms; | ||
Delta Time Measurement Accuracy (Full Bandwidth) | Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 | |||
Vertical System | ||||
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously | |||
Volts Range | 2mV/div to 100V/div at input BNC | |||
Bandwidth | 70MHz | 100MHz | 150MHz | 200MHz |
Rise Time at BNC( typical) | 5ns | 3.5ns | 2.3ns | 1.8ns |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled | ±400V(100V/div-20V/div); ±50V(10V/div-5V/div); ±40V(2V/div-500mV/div); ±2V(200mV/div-50mV/div); ±400mV(20mV/div-2mV/div); | |||
Math | +, -, *, /, FFT | |||
FFT | Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point | |||
Bandwidth Limit | 20MHz | |||
Low Frequency Response (-3db) | ≤10Hz at BNC | |||
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div. ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div. | |||
DC Measurement Accuracy, Average Acquisition Mode | Measurement Type: Average of ≥16 waveforms with vertical position at zero Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected. Measurement Type: Average of ≥16 waveforms with vertical position not at zero Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]. | |||
Volts Measurement Repeatability, Average Acquisition Mode | Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |