Specifications
Gas leak detector PGas-24 CO2+NH3 carbon dioxide and ammonia handheld Gas Tester
Gas leak detector PGas-24 CO2+NH3 carbon dioxide and ammonia handheld Gas Tester
PGas-24 Portable 2 in 1 Gas Detector,can continuously measure the concentrations of any two kinds of gas continuously in buildings,offices,laboratories, greenhouse, greenhouses & etc.
Main functions:
Able to detect O2,CO2 continuously Display O2 or CO2 concentration alternating,(5 seconds alternately) Auto self-calibration when power on Acoustooptic alarm when battery exhausted
PGas-24 Portable2 in 1 Gas Detector, can continuously measure the concentrations of any two kinds of gas continuously in buildings, offices, laboratories, greenhouse, greenhouse &etc.
1) Jack of probe
2) Instruction light of CO2
3) Instruction light of O2
4) Screen
5) Calibration button
6) Q2/CO2 , swith button
7) Swith
8) Sensor
Note : this figure is based on model PGas-24-O2/ CO2
Able to detect O2,CO2 continuously
- Display O2 or CO2 concentration alternating, (5 seconds alternately)
- Auto self-calibration when power on
- Acoustooptic alarm when battery exhausted
Technical parameters
Parameter | Characteristics |
Measuring principle | CO2;solid electrolyte sensor O2 ,H2S &etc: electrochemical |
Sampling method | Diffusion |
Operation environment | 0-40°C, ≤80% RH (no condensation) |
Display | Digital display(unit :%) |
Power supply | 3 dry cell *4/AC100V (using a dedicated AC adapter ) |
Battery life term | About 20 hours (when using alkaline batteries) |
Size | Monitor :76(W)*27(D)*145(H)mm |
Detector:28(W)*27(D)*170(H)mm |
About 250g |
Length | 100cm |
Measuring gas (any two gases)
Measuring gas | Range | Accurancy |
CO2 | 0.04 -5.00%vol | ±30%rdg |
O2 -1 | 5.0%-30.0%vol | ±3%F.S |
O2 -2 | 0-30.0%vol | ±0.7%F.S |
H2S | 0-100ppm | ±5%F.S |
CO -1 | 0-1000ppm | ±5%F.S |
NH3 | 0-2000ppm | ±5%F.S |
SO2 | 0-100ppm | ±5%F.S |
Cl2 | 0-50ppm | ±5%F.S |
Edited by ZACK