12 lead 12 channel digital ecg monitor ECG -912 price of ecg machine
Features:
1. Twelve Channel digital ECG machine with Interpretive. |
2. Simultaneous 12 lead acquisition, 12 channel, 6channel printing form at choice. Date, time and parameters, including paper speed, heart rate, sensitivity, filter status, and etc. print out. |
3. Designed with a high-resolution thermal printer to print out ECG waveform, annotation as well as related parameters for diagnosis reference. |
4. Recording paper for ECG-912 is 210mm in width. |
5. Simultaneous 12 lead acquisition. |
6. Visual display of operation menu, ECG waveform and parameters. |
7. Digital isolation technology is adopted to minimize time/temperature drift of components so as to promote adaptability of the unit to circumstance |
8. Digital filter for effective inhibition of baseline drift, interference, as well as automatic position of baseline. |
9. Self-test upon powering on. |
10. Function of rhythm lead for observing abnormal ECG waveform & heart rate. |
11. Automatic measurement and interpretation of ECG waveform to relieve doctors from strain. |
12. Multiple print formats include 6-channe and 12-channel. |
13. AC/Rechargeable battery for continuous examination when AC power supply is unavailable. For battery operation, ECG-912 is equipped with a charger & system for battery capacity management and protection itself from excessive discharge. |
14. Safety level for ECG-912corresponds to Class I, type CF. |
Specification
Lead | Standard 12 leads |
Input Circuit | Isolated input circuit Protection against defibrillation and pace making |
Data Acquisition | Simultaneously 12 lead acquisition |
Calibration Voltage | 1mV±5% |
Sampling Rate | 1ms |
A/D Converter | 12 bit |
Print Format | Automatic/Manual: 6 channel, 12 channel Neutral value + Rhythm lead |
Operation Mode | AUTO: Automatic lead change; Automatic measurement and interpretation |
MAN: Manual lead change | |
Parameter Measurement | Ventricle heart rate; P-R interval; QRS duration; QT/QTC interval; P/QRS/T axis; RV5/SV1 amplitude |
Filter | AC filter, EMG filter, DFT filter |
CMRR | >60dB >100dB (AC filter in use) |
Input Circuit Current | ≤0.1mA |
Input Impedance | >50MW |
Patient Leakage Current <10mA | |
Time Constant | ≥3.2s |
Frequency Response | 0.05 ~ 100Hz |
Noise Level | <15mVp-p |
Threshold | ≤20mV |
Skin Voltage Tolerance | ±300mV |
Sensitivity | 5, 10, 20mm/mV |
Baseline Control Dimensions of Packing | Automatic baseline control Automatic inhibition of baseline drift |
Dimensions | 400mm*325mm*84.5mm |
Dimension of Packing | 510mm*430mm*230mm |
N,W | 6kg |
G.W | 8kg |
Environment Conditions | Transportation | Storage | Operation |
Temperature: | -40℃~+55℃ | -10℃~+40℃ | +5℃~+40℃ |
Relative Humidity: | 25%~95%(Non condensed) | 25%~80% | 25%~80% |
Atmospheric Pressure: | 700hPa~1060hPa | 700hPa~1060hPa | 860hPa~1060hPa |
Accessories:
Patient cable…………………1 PC
2.Limb electrode………………………4 PCS
3.50mm X 20m roll ECG paper………1 Roll
4.Three plugged power cable…………1 PC
5.Chest electrode……………………6 PCS
6.Backup AC fuse……………………2 PCS
7.Operating instructions……………1 Copy
8.Earth connecting line……………1 PC
9.Certificate……………… ………1 Copy