TH2827B,high precision lcr meter,Equal to Agilent E4980AL LCR Meter,500kHz Lcr

TH2827B,high precision lcr meter,Equal to Agilent E4980AL LCR Meter,500kHz Lcr

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
xiamen
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Fujian, China
Model Number:
TH2827B

Xiamen Wellzion Electronics Co., Ltd.

Business Type: Trading Company
Xiamen Fujian China
Main Products: Power Supply ,Oscilloscope ,Multimeter ,Spectrum Analyzer ,Temperature Test Instruments

Product Details

Specifications

TH2827 series is a new precision LCR meter with various functions
and a higher test frequency.0.05% basic accuracy.

TH2827B,high precision lcr meter,Equal to Agilent E4980AL LCR Meter,500kHz Lcr

 

TH2827B,high precision lcr meter,Equal to Agilent E4980AL LCR Meter,500kHz Lcr

Display480*RGB*272 4.3-inch TFT LCD display
Frequency of test signal
TH2827A 20Hz ~ 300kHz
TH2827B 20Hz ~ 500kHz
TH2827C 20Hz ~ 1MHz
Minimum resolution 10mHz, 4-digit frequency input
Accuracy 0.01%
AC Level
Voltage range of test signal 10mV ~ 2Vrms
Minimum resolution of voltage 100μV, 3-digit input
AccuracyALC ON10% x set voltage + 2mV
ALC OFF6% x set voltage + 2mV
Current range of test signal100μA ~ 20mA
Minimum resolution of current1μA, 3-digit input
AccuracyALC ON10% x set current + 20μA
ALC OFF6% x set voltage + 20μA
DC bias voltage source
Voltage/Current range 0V ~ ±5V / 0mA~ ±50mA
Resolution 0.5mV / 5μA
Voltage accuracy 1% x set voltage + 5mV
ISO ON Be used for the bias test of inductance and transformer
AC Source impedanceISO ON100Ω
ISO OFF30Ω,50Ω,100Ω selectable
DCR source impedance 30Ω,50Ω,100Ω selectable
Test parameters of LCR|Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc
Parameter display of test pageOne set of main/sub parameter, 10-point list sweep
Test parameters of transformerDCR1(primary, 2-terminal),
DCR2(secondary, 2-terminal),
M (mutual inductance), N, 1/N,
Phase, Lk(leakage inductance),
C(primary, secondary capacitance), balance test
Basic accuracyLCR test parameter 0.05%
N 0.10%
CalibrationWarm-up time 30 seconds;
Environment temperature: 23±5ºC;
Signal voltage: 0.3Vrms-1Vrms;
Zeroing: After OPEN or SHORT;
Length of test cable: 0 m
Measurement time (10 kHz)Fast: 13 ms / time
Medium: 67 ms / time
Slow:187 ms / time
Plus the refresh time of display
character
Display range of
LCR parameter
| Z | , R ,X,DCR0.00001Ω ~ 99.9999MΩ
|Y|,G,B 0.00001μs ~ 99.9999s
C 0.00001pF ~ 9.99999F
L 0.00001μH ~ 99.9999kH
D 0.00001 ~ 9.99999
Q 0.00001 ~ 99999.9
θ(DEG) -179.999º ~ 179.999º
θ(RAD) -3.14159 ~ 3.14159
Δ% -999.999% ~ 999.999%
Equivalent circuit Serial, Parallel
Range mode Auto, Hold
Trigger mode Internal, Manual, External, Bus
Average times 1-255
Calibration functionOpen,short calibration with full frequency or dot frequency,Load
Math operation Direct reading, ΔABS, Δ%
Delay time setup 0-999, minimum resolution: 100us
Comparator10-bin sorting, BIN1-BIN9, NG,AUX
Bin counter
PASS/FAIL on front panel,LED indication
List sweep10 points list sweep;
Frequency, AC voltage/current,internal/external bias voltage/
current can be swept;
Each sweep point can be sorted separately;
Internal nonvolatile memory100 sets of LCRZ setting files
201 times test results
External USB memoryGIF files
LCRZ setting files
Test data can be stored via USB memory directly.
InterfaceI/O interface HANDLER on rear panel
SCI USB, RS232C
PCI GPIB (optional)
NI LAN
Memory interface USB HOST (front panel)
Bias current source
control interface
DCI
External DC bias current source can be controlled by using DCI interface.
The maximum bias current can reach 120A.
Option. Only choose either DCI or GPIB
General Specifications
Operating temperature and humidity0ºC ~ 40ºC, 90%RH
Power supplyVoltage 99V-121V, 198V-242V AC
Frequency47Hz-63Hz
ConsumptionMax. 80 VA
Dimension(W*H*D)280 mm * 88 mm * 370 mm(with no sheath)
369 mm * 108 mm * 408 mm(with sheath)
Weight Approx. 5 kg

 

TH2827B,high precision lcr meter,Equal to Agilent E4980AL LCR Meter,500kHz Lcr

ModelAgilent E4980ALTH2827 Series
Frequency20 Hz to 300 kHz/500 kHz/1 MHz20 Hz to 300 kHz/500 kHz/1 MHz
Test signal level 0 to 2 Vrms/0 to 20 mArms10mV ~ 2Vrms/ 100μA ~ 20mA
Range mode Auto, HoldAuto, Hold
Trigger mode Internal, Manual, External, BusInternal, Manual, External, Bus
Programmable list sweep 201 points10 points
Remote control GPIB, LAN, USBGPIB(optional), LAN, USB
Delay time setup 0-999, minimum resolution: 100us0-999, minimum resolution: 100us
Average times 1 - 2561-255
Comparator8-bin sorting;Bin counter10-bin sorting;Bin counter
Equivalent circuit Serial, ParallelSerial, Parallel
Basic accuracy0.1 % @ SHORT
0.05 % @ MED/LONG
0.1%@ N
0.05%@ LCR test parameter
ParametersCp-D/Q/G/Rp,Cs-D/Q/Rs,Lp-D/Q/G/Rp,Ls-D/Q/Rs,R-X,Z-Ød/Ør,G-B,Y-Ød/Ør,Lp-Rdc, Ls-Rdc|Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc
Storage devicesInternal/USB memoryInternal/USB memory
Cabinet dimensions (mm)370 (W) x 105 (H) x 390 (D) mm280 mm * 88 mm * 370 mm
Weight5.3 kgApprox. 5 kg

Contact Supplier

Ms. Melissa Zhang Chat Now
Telephone
86-592-5562446
Fax
86-592-5562446
Address
ROOM 608,B BUILDING,SEG E-MART, NO.806 YUANSHAN NAN ROAD,XIAMEN,FUJIAN,CHINA Xiamen,Fujian

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electronic Measuring Instruments > Other Electronic Measuring Instruments
Categories
Hi~