RF-1/RF-2 automatic water pump controller water pump timer
USD $10 - $60 /Set
Min.Order:20 Sets
Tenglong Electronics Meter Co., Ltd.
RF-1/RF-2 lubricate controller paramters
1 rated range : AC 110~240V AC24V, 50/60HZ DC24V 12V
2 voltage range : 85-110% rated voltage
3 work environmental temperature :-10~+45°c
4 reset mode : manual
5 oil pump circulates time sets up range : 1-999 per second
6 oil pump stops time sets up range :2-999 per cent
7 control output : a opening/close group
8 output contact capacity : AC240V3A resistive load
9 timing error : ≤±1 Mantissa
10 power consumption : 240V50HZ≤3W
11 data back up : about 10 years (25°c).
12 time setting range to stop the oil pump:
RF-1: 2-999 cent RF-2: 1cent-99hour59cent
13 control output:
RF-1: one group of normally open/closed contact
RF-2: one group of normally open contact
.