gel 12v40ah deep cycle lead acid battery

gel 12v40ah deep cycle lead acid battery

USD $37.1 - $38.5 /Piece

Min.Order:100 Pieces

Supply Ability:
10000 Piece / Pieces per Month
Port:
Shenzhen Yantian
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
SAKO,CSSB
Model Number:
6-FM-40
Usage:
UPS
Voltage:
Other, 12v
Sealed Type:
Sealed

Dongguan Shensong Power Co., Ltd.

Business Type: Manufacturer,Trading Company
Dongguan Guangdong China
Main Products: 6V4AH lead acid battery ,12V7AH lead acid battery ,12V17AH lead acid battery ,12V100AH lead acid battery ,12V200AH lead acid battery

Product Details

Specifications

solar street lights VRLA storage battery12V40Ah 
1.low self-discharge 
2.With CE ,ULcertificate

 

Application

 

Maintenance free storage battery 12V40Ah  is widely used among the field of UPS,telecommunication system,power station system,railway system,emergency lighting system,automatic control system,marine equipment,alarm system for fire protection,security,solar wind powered systems,portable instruments,medica equipment, electric instruments,electric vehicles,computer backup power ,etc. all our products are CE,UL,ROHS approved

 

 

 

 

Product features

 

1.Low self-discharge:At theambient temperature 250C,the rate of self-discharge less than 1.8% after 28 days storage.
2.Wide operating temperature range:Shensong battery can charge by 0~400C ,discharge by -20~+550C and store by-15~+500C.
3.Good sealing capability:No pollution and corrosion, which ensures Shensong battery operate sately and efficiently in side and vertical position.The sealed construction can combine the generated gas to water,and noneed to add water or check their specific gravity during the life of Shensong batteries.
4.Good electric conductivity:Adopting red copper with silver plated patent terminal canmake batteries discharge with high current.

  

The specification

 

Lead Acid Battery  12V40AH    

Nominal Voltage

12 V

Rated Capacity (20 hour rate)

40AH

Dimensions

(Length*Width*Height*Total Height )/mm

197*165*170*170 mm

Weight Approx

12.1kg

CHARACTERIESTICS

Capacity

25°C

20 Hour rate

40.9AH

10 Hour rate  

35.3AH

5 Hour rate

30.4AH

1 Hour rate

19AH

Internal Resistance

Fully charged battery at 25°C

8m Ω

Capacity affected by temperature

(20 hour rate)

40°C

25°C

0°C

-15°C

107%

100%

76%

56%

Self-Discharge

At 25°C

Capacity after 3 month storage

Capacity after 6 month storage

Capacity after 12 month storage

91%

82%

64%

Terminal Type

B9,I3,M8

Charge

(Constant Voltage)

Cycle use

Initial Charging Current less than 9.5A                       

Voltage 14.4~15V 

Float use

Voltage 13.5~13.8V

 

 

 

 

 

 

Notice

 

1. According to the requirement of application and design to choose battery model,characteristics and mounting method.

 

2. Avoid mixing use of the batteries with different capacity,manufacturers,characteristics and models.

 

3. It is recommended to charge the battery using the method of constant voltage-limited current.Under the ambient temperature 25
:for standby use,the charging voltage is2.23-2.30V/cell,and no limit on the maximum current;for cycle use, the charging voltage is 2.40-2.50V/cell,average charging voltage:2.35-2.4V/cell.The maximum current is 0.3C10(C10 is the rated capacity of discharging at 10 hours rate).

 

4. During operating,please sdjust the battery charging voltage according to the ambient temperature. The temperature compensation coefficient is -3mV/℃ cell for standby use ,i.e. the temperature increases 1 
,the charging voltage decreases 3mV/cell.The temperature compensation coefficient is -5mV/ cell for cycle use;average charging time:-4mV/ cell.

 

5. Do not charge the battery in a sealed container or in upside down position.It is recommended to charge thebattery in a well ventilated place.

 

6. Do not charge the battery near a heater,or the place where heat accumulation may occur.Do not charge the battery in a place where there is direct sunshine.

 

7. Never have the batteries deposited with organic solvents to prevent the container from being out of shape or corrosion.

 

8. Battery should never be stored in a discharge state for a long period of time ,please recharge the battery after discharge to keep the capacity.During operating,do not over discharge to avoid the plates severe sulphation which affects the service life and capacity.

 

9. Do not over charge the battery ,as the safety vent opens constantly,which will cause the loss of water,finally shorten the service life of battery.

 

10. Red color stand for positive,and black for negative.Please connect the pole of batteries correctly.

 

11. keep the whole battery clean and connection strong.Avoid the damage due to the loose connection.

 

12. Do not disassemble or throw the battery into fire,against the explosion.

 

Contact Supplier

Ms. Anny li Chat Now
Telephone
86-0755-28994210
Address
Room503,Chengtou Business Center,546 Qinglin Road,Central Walk,Longcheng Street,Longgang District, Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Batteries > Storage Batteries
Categories
Hi~