solar charger controller for solar system
USD $15 - $20 /Piece
Min.Order:500 Pieces
Shenzhen Ecsson Technology Co., Ltd.
solar charger controller
1.Voltage: 12V/24V auto
2.Current:10A
3.CE&ROHS
lar charger controller
Model | ESC-010 |
Total rated charge current | 10A-20A |
Total rated load current | 10A-20A |
System voltage | 12V 24V/12V AUTO |
Overload, short circuit protection | 1.25 times the rated current for 60 seconds, 1.5 times the rated current for 5 seconds overload protection actions >3 times the rated current of short circuit protection |
Empty | load loss <6mA |
Charging circuit voltage drop | Not more than 0.26V |
Discharge circuit voltage drop | ≤0.15V |
Overpressure protection | 17V,X2/24V |
Operating Temperature | Industrial: -35°Cto+55°C |
Enhance the charging voltage | 14.6V,; X2/24V(Duration:10min)(Discharge only if there have been calls) |
Enhance the charging voltage | 14.4V; X2/24V;(Duration:10min) |
Float voltage | 13.6V; X2/24V;(Duration:Voltage down to return to action until the charge) |
Charge return voltage | 13.2V X2/24V |
Temperature added | -5mV/°C/2V(Upgrade, direct charge, float, charge return circuit compensation); |
voltage | 12.0V; X2/24V |
Put voltage over | 11.1V( The initial discharge rate compensation amendment put voltage (load voltage); X2/24V |
Overdischarged back voltage | 12.6V; X2/24V |
Control | Charging pulse width modulation to PWN |