HTF-(B) Fire-control Oblique Flow Smoke Centrifugal Fan Draught fan
USD $1 - $9 /Unit
Min.Order:1 Unit
Zhanjiang Weida Machinery Industrial Co., Ltd.
HTF-(B) Fire-control Oblique Flow Smoke Centrifugal Fan Draught fan
Specification and model:
Type | Model (No) | Power(kw) | Rotation (r/min) | Volume(m3/h) | Pressure(Pa) |
HTF-(B)-Ⅰ | 3 | 2.2 | 2800 | 4070~5305 | 915~710 |
4 | 4 | 2900 | 54030~7860 | 1143~910 | |
4.5 | 5.5 | 2900 | 5880~9520 | 1247~910 | |
5 | 5.5 | 2900 | 7360~1300 | 1250~805 | |
6 | 7.5 | 2900 | 15600~20840 | 916~776 | |
7 | 11 | 1450 | 19680~25700 | 1018~878 | |
8 | 15 | 1450 | 28320~37821 | 978~866 | |
9 | 18.5 | 1450 | 36547~44398 | 878~895 | |
10 | 22 | 1450 | 40750~54081 | 1134~947 | |
11 | 30 | 1470 | 48530~60123 | 1128~870 | |
12 | 30 | 980 | 46034~70231 | 1100~850 | |
13 | 30 | 980 | 56845~89536 | 986~680 | |
15 | 37 | 980 | 60438~116420 | 1150~650 | |
HTF-(B)-Ⅱ | 5 | 5.5/4.5 | 2900 | 7360~1300 | 1250~805 |
1450 | 3680~6500 | 313~201 | |||
6 | 7.5/5.5 | 2900 | 15600~20840 | 916~776 | |
1450 | 7800~10420 | 229~194 | |||
7 | 11/9 | 1450 | 19680~25700 | 1018~878 | |
960 | 13029~17015 | 644~385 | |||
8 | 15/13 | 1450 | 28320~37810 | 978~866 | |
960 | 18750~25030 | 429~380 | |||
9 | 18.5/13 | 1450 | 36547~44398 | 978~895 | |
960 | 24196~29395 | 429~392 | |||
10 | 30/22 | 1450 | 40750~54081 | 1134~949 | |
960 | 36979~35805 | 479~415 | |||
11 | 30/13 | 1450 | 48530~60123 | 1128~870 | |
960 | 36398~450192 | 494~381 | |||
12 | 30/15 | 960 | 46034~70231 | 1100~850 | |
720 | 34526~52670 | 619~478 | |||
13 | 30/15 | 960 | 56845~89536 | 986~680 | |
720 | 42637~67152 | 555~383 | |||
15 | 30/18 | 960 | 60743~116420 | 1150~650 | |
720 | 45328~87315 | 647~366 |
Function:
HTF-(B) Fire-control Oblique Flow Smoke Exhaust Fan applicable scope in the basement of cinema, shopping malls, hotels, office buildings/high temperature fire control and ventilation, also for high-rise building and civil construction of the central air conditioning unit section of the host.What else can be used as general factory of ventilation and exhaust.Does not contain a sticky in conveying gas;Viscosity of particle should be less than 150 mg/m after.Fan can under the condition of the high temperature of 280 ° C security operation more than 30 minutes, when the gas temperature of 120 ° C or less use for a long time.Can according to the different requirements of senior civilian construction, driven by variable speed or speed form, one machine in order to achieve dual (that is, the common ventilation, exhaust, and fire is high temperature smoke) purposes;Leaf type can be divided into axial flow and inclinedflow, use this series of fan has more extensive use performance.