API 6A Plug Valve/Union Connection in oil and gas industry
USD $20 - $2,000 /Piece
Min.Order:5 Pieces
Shaanxi APS Machinery Equipment Co., Ltd.
API 6A High Pressure Plug Valve/Union Connection/cock valve
1.Product Overview
I produced the specification level Plug valve products for PLS3, performance levels for PR2, which can be of similar products with SPM's interchangeable equipment widely used in cementing and fracturing equipment.
a.High pressure plug valve is a very important fitting for cementing, well cementing and crushing and is also applicable to control other high pressure fluid. Plug valve is combined by valve body, seal arcing segment, plug cock, etc.
b.The low torque and high pressure plug valve designed and manufactured by our company are all made by high quality and high strength structural alloy steel. Strict heat treatment ensures even metallographic structure and loading capacity. The materials completely conform to USA ASTM and AISI standards and products technical index fully matches with API Spec 6A standard. Product joints can be connected by joint thread, pipeline thread, butt welding or non-pressure sealing end;
c.There buckle models are provided for the terminal of plug valve: union plug valve, LP female connection and LP external thread. In according to users’ needs, we can design the high pressure plug valve with a base;
d.High pressure plug valve has different specifications: 1’’, 2’’, 3’’ and different cold working pressures: 42Mpa(6000Psi),70Mpa(10000Psi),105Mpa(15000Psi). Plug valve and maintenance package used under normal temperature, low temperature and sulfurous gas environment are available.
2.Design Features
Plug valve from the valve body, cocks, seals and other parts arc pieces (see the specific one). Its working principle is: By adjusting the position of the tap handwheel for control flow size. Between the body and cock, sealed arc chip seal, seal arc due to the high precision sheet, and using a special grinding process to ensure that products in the high-pressure working conditions are not leaking.
a.Stable pressure-bearing: equipped with changeable elastic nitrile rubber sealing ring, firm wall thickness; it is able to bear pressure under high pressure line;
b.Convenient to exchange: union joints on both ends and can be exchanged with LP, UN internationally due to inch size is applied;
c.Simple maintenance: it is unnecessary to dissemble from pipeline to maintain or repair plug valve, and no need to use special tools in case of disassembling;
d.Good sealing and preservation: the plug cock is fine finished by special coating technology;
e.Visible valve position: the symbols of fully open and close of valve are clearly marked on the plug cock cap. The tripping spring restricts valve in proper positions.
Main Technical Parameters of Plug valve
a.High pressure Plug valve
Specifications | buckling size | cold working press | Terminal connection type | Buckle model |
SF42 | 1"×2" | 42Mpa(6000psi) | Internal thread ,External thread(LP,NU) | |
union fig1002 | M×M | |||
Remark:1“F”-threaded joint,“M”-sphere joint;“LP”-pipe thread, “UN”-un-thickening tubing thread |
b.Example:SF105-M×F-2"×2"-fig 1502 Structure of union plug valve
c. Parts list of (FXM) high pressure fig plug valve
No. | Name | Qty |
| No. | Name | Qty |
1 | Valve body | 1 |
| 12 | Square sealing ring | 2 |
2 | Sealing washer | 1 |
| 13 | Sealing arcing shim | 2 |
3 | Spring rand | 1 |
| 14 | Plug cock | 1 |
4 | Wing union | 1 |
| 15 | Valve deck sealing ring | 1 |
5 | Rand | 3 |
| 16 | Support band of valve deck sealing ring | 1 |
6 | Retaining spring | 1 |
| 17 | Elastic cylindrical pin | 1 |
7 | Retaining pin | 2 |
| 18 | Valve deck | 1 |
8 | Locating pin | 2 |
| 19 | Plug cock cap | 1 |
9 | O-shaped sealing ring | 2 |
| 20 | Locknut | 1 |
10 | Sealing ring support band | 2 |
| 21 | Grease fitting | 1 |
11 | Side arcing shim | 2 |
|
|
|
|
High pressure plug valve maintenance package parts are shown as 9,10,11,12,13,14,15,16 and 21 in structure of high pressure plug valve.
4.Precautions
a.The operator shall take into account the drilling / or production operations will feel the temperature of the device, select the appropriate temperature.
b.Plug valve have to undergo a rigorous hydrostatic testing and nondestructive testing at the factory. Disassemble or repair, you must be hydrostatically tested. Rated working pressure test pressure regulator 10 minutes, without leakage (Note: pressure test should be drained before the air in the system).
c.Install Plug valve, the operator should wear protective goggles to prevent the installation of a small debris flying eye injury.
5.Caveat
a.Do not use in excess of the rated working pressure conditions.
b.Plug valve design operating temperature of -46 ℃ ~ 121 ℃, when the ambient temperature is below -46 ℃, or contact the fluid temperature is higher than 121 ℃, you should immediately discontinue use.
c.Plug valve can not be removed in the system working pressure.
d.Tighten Hammer Union, the impact force or use of force does not make tightened Hammer Union deformed or damaged.