Single Phase, 220VAC Outdoor Online UPS Power Supply (3KVA)
USD $300 - $500 /Piece
Min.Order:1 Piece
Qingdao Powtech Electronics Co., Ltd.
Single Phase 220VAC Outdoor Online UPS Power Supply ( 1KVA )
Single Phase, 220VAC Outdoor Online UPS Power Supply (1KVA,2KVA,3KVA,6KVA,10KVA)
Single Phase , 220VAC Outdoor Online UPS Power Supply ( 2KVA )
Single Phase/220VAC Outdoor Online UPS Power Supply (1KVA~10KVA)
600VA line interactive UPS power supply / UPS with recharging board
1KVA line interactive UPS/ UPS power supply/UPS with AVR with battery
Single Phase, 220VAC Outdoor Online UPS Power Supply (1KVA~10KVA)
Model:1~10KVA
Nominal frequency:50/60HZ
Output Power factor:0.7/0.8(Optional)
Key Features
ØJETPOWER Outdoor Intelligent High Frequency Online UPS provide continuous pure sine wave AC power supply for outside communications / network equipment.
ØDouble-conversion online design, high temperature resistant, anti-cold, sealing level for IP55; With the wide range of input voltage and frequency of input window (-45% +35% rated voltage and ± 10% rated frequency), in many remote areas of China after a severe test of the grid.
Reliable Power Rich Experience
Mammoth series communication marginal network outdoor UPS is special for wireless communication system of outdoor micro cellular base station and design of a high-performance integrated outdoor online uninterrupted power supply system, has the very high technology advancement and practicability.
High Reliability of the UPS System
ØUsing microprocessor control, directly produce highfrequency pulse width modulation wave (SPWM) control of the UPS inverter, to simplify the UPS control circuit, to improve the stability, to have more real-time UPS to quickly respond to changes in the external environment and guarantee the machine's control circuit is more simple and reliable.
ØUsing digital control techniques, to avoid the traditional analog control temperature drift inherent defects such as hardware parameters, to ensure consistency and reliability of UPS.
Fine dust-proof, water-proof features
According to the overall standard of design dust-proof and water-proof IP55
ØWith a sun protection, heat insulation, roof ventilation
ØWith waterproof and the filtration dust inlet; the cabinet front door shutters with waterproof design, on the back of welding water tank, water tank installed above the net with quick release feature of the dust .
Environmental Adaptability
ØWide input voltage, avoids frequent switching to battery power because of large power grid voltage, reduce battery failure probability, adapt to the power environment in poor areas.
ØInput FrequencyRange 45 ~ 55Hz, to ensure the fuel generator can access all kinds of stability to meet user requirements for use on the oil machine.
Optional aceessories
Heat exchanger
The environment which require higher IP level, we use heat exchanger to effectively reduce the temperature of box inside and improve IP protection level .
Heater and temperature controller
In response to low temperature climate impact of batteries and UPS, we adopt ajustable heating device to ensure the UPS and battery life of normal use.
Application
This UPS is commonly used in the corner of the city, remote roads, mountains, bad environment, such as high temperature ( +50 °C) / low temperature (-40 °C), severe dust, moisture, rain, mist erosion, very poor power quality (voltage long-term higher than 260V or less than 160V, frequency abnormal change) in the area.
Technical Specifications:
Model | 1-10KVA | ||||
1KVA | 2KVA | 3KVA | 6KVA | 10KVA | |
Capacity | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW | 6KVA/4.2KW | 10KVA/7KW |
Nominal Voltage | 220/230/240VAC | ||||
Nominal Frequency | 50Hz/60Hz | ||||
Input | |||||
Voltage Range | 115~295VAC(±3VAC) | 176~297VAC(±3VAC) | |||
Frequency Range | 50HZ:(46~54HZ);60HZ:(56HZ~64HZ) | ||||
Soft Start | 0~100% 5sec | ||||
Power Factor | 0.98 | ||||
Output | |||||
Voltage Precision | 220/230/240X (1±2%)VAC | ||||
Frequency Precision | 50/60HZ±0.05Hz | ||||
Power Factor | 0.7/0.8(optional)standard 0.7 | ||||
Wave Distortion | Linear load <3% Non-linear load <6% | ||||
Overload Capability | Overload (110% ~ 150%) for 30 seconds,then automatically transfer to bypass.When load is normal,it can automatically transfer to normal mode. | ||||
Crest Factor | 3:1 | ||||
Transfer Time | 0ms(AC to DC ) | ||||
Battery | |||||
DC Supply Voltage | 36VDC | 96VDC | 96VDC | 240VDC | 240VDC |
Charge Current | 4A/8A(optional) | 4A/8A(optional ) | 4A/8A(optional) | 4.2A | 4.2A |
Internal Battery Capacity | (38/65/80/100AH)optional | ||||
Panel Display | |||||
LCD | Display input and output voltage, frequency, battery voltage | ||||
Communications | |||||
communicate interface | RS232SNMP card(optional) | ||||
Work Environment | |||||
Temperature | 0~40ºC | ||||
Humidity | 0~95% (Non-condensing) | ||||
Storage Temperature | -25ºC~55ºC | ||||
Elevation | < 1500m | ||||
Physical Character | istics | ||||
Weight(KG)/N.W | 85 | 125 | 125 | 150 | 155 |
Dimensions ( Wx D x H )mm | 613×640×954 | 650×753×1227 | 650×753×1227 | 940×940×1770 | 940×940×1770 |
1. Major manufacturer,Competitive price, good quality and on-time delivery
2. ISO9001:2008 certification
3. Many years' production experience
1. Best prices
2.Good after-sale response
3. Small order accepted
4. Excellent workmanship