INQ series INVERTER use the latest IGBT technology, with special designed control circuit, capable of precisely controlling all parameters of your equipments and providing high quality and reliable AC power source for your precise equipments. Taking small volumes, low noise with high stabilities and easy operation as important elements, the equipments also enjoy consistent excellent qualities and protections.
INQ series utilize microprocessor control to replace traditional analog or digital components in its control board. The design not only increases the MTBF but also provide a precise and reliable output. Additional feature with the microprocessor control is to communicate with laptop/equipment that is connected to the INVERTER via RS-232/RS-485 interface. By using the monitoring software, users can easily monitor INVERTER and can schedule to turn on/off INVERTER. Up to 3996 events can be recorded and saved in the INVERTER.
Technical data sheet:
INQ 6K3~60K3Three ins and one out | |||||||||
Model | 6K3 | 10K3 | 15K3 | 20K3 | 30K3 | 40K3 | 50K3 | 60K3 | |
Capacity (VA/W) | 6K/4.8K | 10K/8K | 15K/12K | 20K/16K | 30K/24K | 40K/32K | 50K/40 | 60K/48K | |
AC input (Optional) | Three phase with four Lines+ground wire,380V±25% | ||||||||
Noise | ≤60dB(distance 1m) | ≤65dB(distance 1m) | |||||||
Size (W×D×H,mm) | 620×343×995 | 650×700×1510 | |||||||
Weight(Kg) | 130 | 165 | 180 | 220 | 400 | 450 | 530 | 620 | |
Common parameters | |||||||||
AC Input (Optional) | Frequency | 50Hz /60Hz ± 10% | |||||||
Power factor | ≥0.95 | ||||||||
DC input | Nominal voltage | 192VDC | |||||||
AC Output | Voltage | {0> 220V± 0.5%<}0{><0}
| |||||||
Voltage regulation | Stable ±1%,dynamic ±2%, (<20ms for 0-100%load change) | ||||||||
Frequency stabilization | 50Hz /60Hz ± 0.5% | ||||||||
Frequency slow rate | < 1Hz / second | ||||||||
Transient response | ± 0.4% (100% instant load fluctuation) | ||||||||
THD | <3% for linear load; <5% for non-linear load | ||||||||
Wave form | True sine wave | ||||||||
Alarm | DC input under voltage | Beeps once every 1 second when DC input under voltage | |||||||
Inverter fault | Beeps continuously | ||||||||
Protection | DC input under voltage | Auto shutdown when DC input voltage below preset voltage | |||||||
Overload | 110150% overload for 10 seconds, then auto jumps to AC BYPASS; Auto resumes when overload removed | ||||||||
Over temperature | Auto jumps to AC BYPASS when INVERTER internal temperature >85°C | ||||||||
Output short circuit | Current limits, auto shutdown, no fuse switch protection. | ||||||||
Inverter fault | Auto jumps to AC BYPASS | ||||||||
Noise Filter<0} | 10~10KHz at 40 db; 100KHz~100MHz at 70 db | ||||||||
Display | LCD | AC input and output voltage, frequency; DC voltage and output power (%), etc | |||||||
LED (DC Low) | LED (DC low) turns on when DC input voltage low | ||||||||
Ambient | Temperature | 0~40 | |||||||
Relative humidity | 10%~90% (No condensation) | ||||||||
Altitude | 1500 meters |