wind turbine pue sine wave inverter all-in-one 10kw
USD $810 - $810 /Sheet
Min.Order:3 Sheets
Dezhou Holead Imp & Exp Co., Ltd.
wind turbine pue sine wave inverter all-in-one 10kw
1,Summary
The product is that I developed a special type of intelligent control of wind generators (Solar) charge control machine, a very comprehensive protection (including overload protection, over current protection, high temperature protection, surge short-circuit protection, input polarity protection, battery high and low pressure protection, with built-in fuses, etc.), instructions function. It uses high-quality non-contact power devices to ensure high-quality products, high-performance. This machine is used as a standard sine wave output
2,Using method
Connect sufficient power supply to the input power inverter, Power supply voltage is in the prescribed limit, Power cord must have adequate current carrying capacity. Power cord is as far as short, Open the inverter's power switch, Output load in the boot before or after the boot can access.
3,Power Requirements
l Input supply voltage scope DC 96V.
l. Input power cord must be firmly connected with the inverter .The carrying capacity of the power cord should be enough.
4,Line Connection
5,Technical parameter
No. | Item | Technical data |
1 | Input voltage | 216VDC |
2 | maximum input current | 75A |
3 | output voltage | 120VAC±3%/208VAC threephase threephase AC |
4 | output frequency | 60±0.1PERCENT |
5 | Rated power | 10000W |
6 | maximum continuous output power | 10000W |
7 | peak power | 1100W/3s |
8 | output waveform | Standard sine wave |
9 | harmonic content | ≤1 PERCENT |
10 | load power factor | 0.90 |
11 | dynamic voltage transient range | ±3 PERCENT |
12 | transient response recovery time | ≤100ms |
13 | invert efficiency | ≥80 PERCENT |
14 | No-load current | 900mA |
0,Attentions
1. The inverter can only take less than their rated power load requirements.
2. The inverter input voltage range for the DC184 ~ 261V, the voltage will be too high to damage.
3. If the inverter output after the boot load is too large to protect the resulting output, it should be turned off, remove the load, 10S after boot, or frequent overload will be to damage the boot.
4. The inverter to the input and output for the total equipment, Anode input power is the prohibition of contact with the output load, or it will cause a short circuit.
5. The prohibition of the inverter and the City connection, otherwise there will be an electric shock hazard. 6. Please do not use wet hands or in wet environment using the inverter in order to avoid electric shock.
7. Without the use of the inverter, please put the switch OFF.
8. When the inverter switches are in the OFF position, it does not affect battery charging.
9. This machine will produce high-temperature work, around the prohibition of flammable and explosive items! Please maintain a good ventilation conditions.