lead acid maintenance free 12v 1.3ah Automatic ramp door battery
lead acid maintenance free 12v 1.3ah Automatic ramp door battery
lead acid maintenance free 12v 1.3ah Automatic ramp door battery
lead acid maintenance free 12v 1.3ah Automatic ramp door battery
lead acid maintenance free 12v 1.3ah Automatic ramp door battery

lead acid maintenance free 12v 1.3ah Automatic ramp door battery

USD $7 - $10 /Piece

Min.Order:500 Pieces

Supply Ability:
1000 Piece / Pieces per Month
Port:
Shenzhen
Payment Terms:
Credit Card PayPal

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
KLD battery
Model Number:
CA1213
Usage:
Other, fire control cabinet,Automatic ramp door,medical instrument
Voltage:
Other, 12v
Sealed Type:
Sealed

Zhengzhou Kanglida Electronic Power Co., Ltd.

Business Type: Manufacturer
Zhengzhou Henan China
Main Products: 4v gel battery ,6v gel battery ,12v gel battery ,gel UPS battery ,gel Solar battery

Product Details

 

 

lead acid maintenance free 12v 1.3ah Automatic ramp door battery

Zhengzhou Kanglida Electronic Power Co., Ltd

1.15 years manufacturing lead acid exide battery in China;

2.Recorded by China Public Security and China Security Yearbook;

3.Qualified Supplier recommended to national security enterprise ;

4.CE and UL Certificated.

 

Advantages
1.The battery is full of power when it’s out of factory, no need to use liquid charge;
2.no memory, no need to discharge battery use, suitable for circuit design;
3.by high partition, adsorption and strong;
4.there is no flowing liquid (poor liquid), does not leak acid and free Upside down;
ply with environmental requirements, ease of use;
6.the use of lead-calcium alloys, battery self-discharge is very low;
7.easy storage, less maintenance;
8.using ABS plastic shell and valve technology for stable quality safe use.
9.fresh lead board , long use life and low pollution

 

Application range

1.UPS

2.Emergency lighting systems

3.Alarm and security system

4.Fire alarm and security system

5.Telecommunication system

6.Backup power for testing and measuring instruments

7.Communication power supply

8.Auto control system

9.Electronic apparatus and equipment

10.DC power supply

 

Speicification

battery characteristic

Nominal voltage

12V

Nominal capacity(20h rate)

1.3Ah

Size

Total height

57mm

length

98mm

width

43mm

height

52mm

Weight

0.51kg

Rated capacity                       25°C(77°F)

20 hour rate(0.065A)

1.3Ah

10 hour rate(0.12A)

1.2Ah

5 hour rate(0.22A)

1.10Ah

1 hour rate(0.78A)

0.78Ah

Internal resistance

in full charge status 25°C(77°F)

75mΩ

Capacity at different temperature(10h)

40°C(104°F)

102%

25°C(77°F)

100%

0°C(32°F)

85%

-15°C(5°F)

65%

Self discharge     25°C(77°F)

capacity after 3 months

91%

capacity after 6 months

82%

capacity after 12 months

64%

Mode of charge (constant voltage)       25°C(77°F)

cycle-use

initial charging current less than0.52A ,                    voltage14.10-14.40V

float-use

Initial charging current less than 0.2A voltage13.50-13.80V

 

lead acid maintenance free 12v 1.3ah Automatic ramp door battery

 

lead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door battery

 

 

 

CE & UL Ceritificate

 lead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door battery

 

 Quality Inspection Report

lead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door battery

 

Factory production pictures

lead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door batterylead acid maintenance free 12v 1.3ah Automatic ramp door battery

 

 

Maintenance and Attention Matters:

1.Battery is not allowed close to Tepid source or basked under the sun for a long time

2. No charge in the obturate container

3. No short circuit. Battery should be stored full of electronic when not in need,and the battery should be charged every three months in order to avoid the irreversible sulphation. When battery case bursts or electrolyte leaks, battery should be changed lest the acid corrosion.

4. No battery in environment with the acid gas.

5. When battery is used as the backup battery,be careful and check it at regular time to avoid the damage battery. Especially the battery beyond one year should be checked in time, and change the less capacity and scrapped battery.( some batteries maybe have voltage but no current; some batteries maybe have current but no voltage; some maybe have both but less capacity: all these conditions cannot meet the work,reach the power-on time. Do not for the small battery,cause the huge losses )

6. Forbidden battery in the fire, otherwise it will cause an explosion.

7. When battery cracks or electrolyte leaks, please use cotton cloth clear it. When skin contacts to

the liquid, please wash with fresh water immediately. See doctor if serious.

8. No wash on the surface of the battery with the organic solution

 

Note:

 

Thanks for your attention, any questions or requests,please do feel free to contact  us.

Tel:18625500662                     Skype: kanglidabattery

 

Contact Supplier

Mr. TianLong He Manager Chat Now
Telephone
86-0371-68753149,13503863022
Mobile
13503863022
Fax
86-371-69381600
Address
Room No.418-423,4 Floor,B building,East of Lianyun road, North of Hanshan dong road,Erqi district, Zhengzhou, China. Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Batteries > Storage Batteries
Categories
Hi~